Changes for page 08 High-speed pulse output
Last modified by Mora Zhou on 2024/08/08 14:35
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Stone1 +XWiki.Jim - Content
-
... ... @@ -447,11 +447,8 @@ 447 447 448 448 This instruction uses absolute drive to perform single-speed positioning. The specified positioning address adopts the absolute method, and the specified position (absolute address) is used for positioning based on the origin. 449 449 450 - {{idname="OLE_LINK365"/}}450 + [[image:3q3.png]] 451 451 452 -(% style="text-align:center" %) 453 -[[image:08_html_7a3c30baa77024fb.gif||height="311" width="800" class="img-thumbnail"]] 454 - 455 455 • Specify the positioning address of user unit with a absolute address in (s1). (It should be in the range of -2,147,483,647 to +2,147,483,647) 456 456 457 457 • Specify the instruction speed of user unit in (s2). (It should be in the range of 1 to 200,000) ... ... @@ -1098,7 +1098,7 @@ 1098 1098 1099 1099 Specify the output pulse duty ratio in (s1). (The setting range is 0 to 1000) 1100 1100 1101 -Specify the output pulse period in (s2). (The setting range is 1 to 32,767 ms)1098 +Specify the output pulse period in (s2). (The setting range is 1 to 32,767) 1102 1102 1103 1103 Specify the device that outputs the pulse in (d). Only Y devices with positioning parameters can be specified. 1104 1104 ... ... @@ -1106,7 +1106,7 @@ 1106 1106 1107 1107 High level time (ms) = set cycle time (ms) x duty cycle / 1000 1108 1108 1109 -Low level time (ms) = period (ms)-high level time (ms) 1106 +Low level time (ms) = period (ms) - high level time (ms) 1110 1110 1111 1111 That is, the period is set to 100ms, if the duty cycle is set to 500, the output is high for 50ms and low for 50ms; if the duty cycle is set to 100, the output is high for 10ms and low for 90ms; If it is set to 900, the output will be high for 90ms and low for 10ms. The fractional part of the calculated pulse output time is output by rounding. 1112 1112 ... ... @@ -1115,13 +1115,11 @@ 1115 1115 **✎Note:** 1116 1116 1117 1117 1. Please be careful not to overlap with other control devices. 1118 -1. About pulse output 1115 +1. About pulse output: This instruction is executed in interrupt mode. When the instruction power flow is OFF, the output stops. (s1) and (s2) can be changed when the PWM instruction is executed. If it is modified to an incorrect parameter, the sending of PWM pulse will be stopped. 1119 1119 1120 -This instruction is executed in interrupt mode. When the instruction power flow is OFF, the output stops. (s1) and (s2) can be changed when the PWM instruction is executed. If it is modified to an incorrect parameter, the sending of PWM pulse will be stopped. 1121 - 1122 1122 **Related device** 1123 1123 1124 -• Per centagemode flag1119 +• Permil mode flag 1125 1125 1126 1126 (% class="table-bordered" %) 1127 1127 |=(% scope="row" %)**Output shaft**|**Y0**|**Y1**|**Y2**|**Y3**|**Y4**|**Y5**|**Y6**|**Y7** ... ... @@ -2614,26 +2614,26 @@ 2614 2614 2615 2615 **C.**When the parameter is 0, Ladder acceleration and deceleration(calculate the pulse frequency one by one) mode is adopted. 2616 2616 2617 -{{id name="OLE_LINK373"/}}{{id name="OLE_LINK374"/}}**D.**When the parameter is 1, Time- minuteladder acceleration and deceleration is adopted.2612 +{{id name="OLE_LINK373"/}}{{id name="OLE_LINK374"/}}**D.**When the parameter is 1, Time-division T-type acceleration and deceleration is adopted. 2618 2618 2619 -**E.**When the parameter is 2, Time- minutes-type acceleration and deceleration is adopted.2614 +**E.**When the parameter is 2, Time-division S-type acceleration and deceleration is adopted. 2620 2620 2621 -**{{id name="OLE_LINK378"/}}(15) Time- minuteacceleration and deceleration parameter**2616 +**{{id name="OLE_LINK378"/}}(15) **Time-division** acceleration and deceleration parameter** 2622 2622 2623 2623 (% class="table-bordered" %) 2624 2624 |**Output axis**|**Y0**|**Y1**|**Y2**|**Y3**|**Y4**|**Y5**|**Y6**|**Y7** 2625 -|Time- minuteintervals|SD912|SD972|SD1032|SD1092|SD1152|SD1212|SD1272|SD13322620 +|Time-division intervals|SD912|SD972|SD1032|SD1092|SD1152|SD1212|SD1272|SD1332 2626 2626 2627 -Time- minuteintervals:2622 +Time-division intervals: 2628 2628 2629 -{{id name="OLE_LINK377"/}}{{id name="OLE_LINK379"/}}This parameter is time interval of time-minuteacceleration and deceleration. The unit is 100us. The value range is 10 to1000.When the value is less than 10, the value is 10. When the value is greater than 1000, the value is 1000.2624 +{{id name="OLE_LINK377"/}}{{id name="OLE_LINK379"/}}This parameter is time interval of Time-division acceleration and deceleration. The unit is 100us. The value range is 10 to1000.When the value is less than 10, the value is 10. When the value is greater than 1000, the value is 1000. 2630 2630 2631 -Time- minuteladder acceleration and deceleration2626 +Time-division T-type acceleration and deceleration 2632 2632 2633 2633 (% style="text-align:center" %) 2634 2634 [[image:08_html_4649b9d5dd0f0a90.gif||height="330" width="700" class="img-thumbnail"]] 2635 2635 2636 -Time- minuteS-type acceleration and deceleration2631 +Time-division S-type acceleration and deceleration 2637 2637 2638 2638 (% style="text-align:center" %) 2639 2639 [[image:08_html_27806ce2da3a3ef0.gif||height="319" width="700" class="img-thumbnail"]]
- 3q3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Jim - Size
-
... ... @@ -1,0 +1,1 @@ 1 +22.0 KB - Content