Changes for page 08 High-speed pulse output
Last modified by Mora Zhou on 2024/08/08 14:35
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Jim1 +XWiki.Stone - Content
-
... ... @@ -447,8 +447,11 @@ 447 447 448 448 This instruction uses absolute drive to perform single-speed positioning. The specified positioning address adopts the absolute method, and the specified position (absolute address) is used for positioning based on the origin. 449 449 450 - [[image:3q3.png]]450 +{{id name="OLE_LINK365"/}} 451 451 452 +(% style="text-align:center" %) 453 +[[image:08_html_7a3c30baa77024fb.gif||height="311" width="800" class="img-thumbnail"]] 454 + 452 452 • Specify the positioning address of user unit with a absolute address in (s1). (It should be in the range of -2,147,483,647 to +2,147,483,647) 453 453 454 454 • Specify the instruction speed of user unit in (s2). (It should be in the range of 1 to 200,000) ... ... @@ -1095,7 +1095,7 @@ 1095 1095 1096 1096 Specify the output pulse duty ratio in (s1). (The setting range is 0 to 1000) 1097 1097 1098 -Specify the output pulse period in (s2). (The setting range is 1 to 32,767) 1101 +Specify the output pulse period in (s2). (The setting range is 1 to 32,767ms) 1099 1099 1100 1100 Specify the device that outputs the pulse in (d). Only Y devices with positioning parameters can be specified. 1101 1101 ... ... @@ -1103,7 +1103,7 @@ 1103 1103 1104 1104 High level time (ms) = set cycle time (ms) x duty cycle / 1000 1105 1105 1106 -Low level time (ms) = period (ms) 1109 +Low level time (ms) = period (ms)-high level time (ms) 1107 1107 1108 1108 That is, the period is set to 100ms, if the duty cycle is set to 500, the output is high for 50ms and low for 50ms; if the duty cycle is set to 100, the output is high for 10ms and low for 90ms; If it is set to 900, the output will be high for 90ms and low for 10ms. The fractional part of the calculated pulse output time is output by rounding. 1109 1109 ... ... @@ -1112,11 +1112,13 @@ 1112 1112 **✎Note:** 1113 1113 1114 1114 1. Please be careful not to overlap with other control devices. 1115 -1. About pulse output : This instruction is executed in interrupt mode. When the instruction power flow is OFF, the output stops. (s1) and (s2) can be changed when the PWM instruction is executed. If it is modified to an incorrect parameter, the sending of PWM pulse will be stopped.1118 +1. About pulse output 1116 1116 1120 +This instruction is executed in interrupt mode. When the instruction power flow is OFF, the output stops. (s1) and (s2) can be changed when the PWM instruction is executed. If it is modified to an incorrect parameter, the sending of PWM pulse will be stopped. 1121 + 1117 1117 **Related device** 1118 1118 1119 -• Per milmode flag1124 +• Percentage mode flag 1120 1120 1121 1121 (% class="table-bordered" %) 1122 1122 |=(% scope="row" %)**Output shaft**|**Y0**|**Y1**|**Y2**|**Y3**|**Y4**|**Y5**|**Y6**|**Y7**
- 3q3.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Jim - Size
-
... ... @@ -1,1 +1,0 @@ 1 -22.0 KB - Content