Changes for page 10 Communication

Last modified by Devin Chen on 2024/04/09 10:21

From version 1.1
edited by Leo Wei
on 2022/06/08 12:57
Change comment: Imported from XAR
To version 2.1
edited by Stone Wu
on 2022/06/14 17:06
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.admin
1 +XWiki.Stone
Content
... ... @@ -491,7 +491,7 @@
491 491  
492 492  A5 C8: CRC check code.
493 493  
494 -For detailed custom protocol instructions, please refer to "[[(% class="wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink" %)__10.7.2 Modbus protocol description__>>path:#_10.7.2 Modbus protocol description]](%%)"
494 +For detailed custom protocol instructions, please refer to "[[(% class="wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink" %)__10.7.2 Modbus protocol description__>>path:#_10.7.2 Modbus protocol description]](%%)"
495 495  
496 496  **✎Note: **
497 497  
... ... @@ -705,7 +705,7 @@
705 705  
706 706  A5 C8: CRC check code.
707 707  
708 -For detailed custom protocol instructions, please refer to "[[(% class="wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink" %)__10.7.2 Modbus protocol description__>>path:#_10.7.2 Modbus protocol description]](%%)"
708 +For detailed custom protocol instructions, please refer to "[[(% class="wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink" %)__10.7.2 Modbus protocol description__>>path:#_10.7.2 Modbus protocol description]](%%)"
709 709  
710 710  **✎Note: **
711 711  
... ... @@ -1743,9 +1743,9 @@
1743 1743  
1744 1744  If it is set to 1, send once and then send once again after timeout.
1745 1745  
1746 -**{{id name="_Toc33979612"/}}(3) Serial port parameter setting**
1746 += **{{id name="_Toc33979612"/}}(3) Serial port parameter setting** =
1747 1747  
1748 -**{{id name="_Toc33979613"/}}1) PORTPARA instruction**
1748 +== **{{id name="_Toc33979613"/}}1) PORTPARA instruction** ==
1749 1749  
1750 1750  -[PORTPARA (s) (N)]
1751 1751  
... ... @@ -2160,14 +2160,20 @@
2160 2160  
2161 2161  == {{id name="_10.7 WECON MODBUS protocol description"/}}**PLCLINK/Fast interconnect function** ==
2162 2162  
2163 -PLCLINK function is used to simplify the fast connection between PLCs. The fast communication of the LX5V series PLC could be achieved only using the configuration parameters without using the communication instruction(RS).
2163 +PLCLINK function is used to simplify the fast connection between PLCs. The fast communication of the LX5V series PLC could be achieved only using the configuration parameters without using the communication instruction(RS).
2164 2164  
2165 -Currently PLCLINK is only applicable to COM2, and could not be used with Modbus and RS instruction at the same time.
2165 +The topological diagram is shown in the figure below.
2166 2166  
2167 -**{{id name="_Toc20639"/}}Features**
2167 +(% style="text-align:center" %)
2168 +[[image:image-20220614170612-1.jpeg]]
2168 2168  
2169 -(1) Create a table
2170 +When using the PLCLINK function:
2170 2170  
2172 +* Master station configuration: Select COM2 port and set the protocol to PLCLINK protocol.
2173 +* Slave configuration: Select COM1 or COM2 and set the protocol to dedicated protocol.
2174 +
2175 +**(1) Create a table**
2176 +
2171 2171  In [Project manager]-[Extended function]-[PLCLINK], right click [PLCLINK], and click it to create a table.
2172 2172  
2173 2173  (% style="text-align:center" %)
image-20220614170612-1.jpeg
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Stone
Size
... ... @@ -1,0 +1,1 @@
1 +41.2 KB
Content