... ... @@ -163,13 +163,13 @@
163 163  |**Error code**|**Content**
164 164  |4085H|When the device specified in the read application instructions (s1), (s2), (s3), (d) exceeds the range of the corresponding device.
165 165  |4086H|When the device specified in the write application instruction (s3) and (d) exceeds the range of the corresponding device.
166 -|4D80H|The sampling time is out of range.​(T,,S,,≤0)
167 -|4D81H|Input filter constant (​​​​​​​α) is out of range (​​​​​​​α​<0 or α>1023)
168 -|4D82H|The maximum ascent rate (​​​​​​​△//T//) is out of range.(△//T//​<0 or//T//​>1023)
169 -|4D86H|The sampling time (Ts) is less than the operation cycle.​​​​​​​​​​​(T//s//<Scanning cycle)
170 -|4D87H|The proportional gain (K//p//) is out of range.​​​​(K//p//<1 or K//p//>32000)​​​​​​​
171 -|4D88H|The integral time constant (Ti) is out of range.(K//i//<0 or K//i//>3600)
172 -|4D89H|The differential time constant (T//d//) is out of range.(K//d//<0 or K//d//>1000)
166 +|4D80H|The sampling time is out of range.[[image:11_html_e20ffef8be00c7de.gif||class="img-thumbnail"]]
167 +|4D81H|Input filter constant ([[image:11_html_89233377f23913d1.gif||height="19" width="24" class="img-thumbnail"]] ) is out of range ([[image:/bin/download/PLC%20Editor2/11%20Special%20instructions/WebHome/11_html_fc04053cc1766938.gif?rev=1.1||alt="11_html_fc04053cc1766938.gif" class="img-thumbnail"]],,[[image:11_html_fc04053cc1766938.gif]] ,,)
168 +|4D82H|The maximum ascent rate ([[image:11_html_b83270b056cb8a08.gif||class="img-thumbnail"]] ) is out of range.[[image:/bin/download/PLC%20Editor2/11%20Special%20instructions/WebHome/11_html_6ec55fb8a0806a8a.gif?rev=1.1||alt="11_html_6ec55fb8a0806a8a.gif" class="img-thumbnail"]],,[[image:11_html_6ec55fb8a0806a8a.gif]],,
169 +|4D86H|The sampling time (Ts) is less than the operation cycle.[[image:/bin/download/PLC%20Editor2/11%20Special%20instructions/WebHome/11_html_5760e7f0e774413a.gif?rev=1.1||alt="11_html_5760e7f0e774413a.gif" class="img-thumbnail"]],,[[image:11_html_5760e7f0e774413a.gif]],,
170 +|4D87H|The proportional gain (Kp) is out of range.[[image:/bin/download/PLC%20Editor2/11%20Special%20instructions/WebHome/11_html_7ce2946bf919a62d.gif?rev=1.1||alt="11_html_7ce2946bf919a62d.gif" class="img-thumbnail"]],,[[image:11_html_7ce2946bf919a62d.gif]],,
171 +|4D88H|The integral time constant (Ti) is out of range.[[image:/bin/download/PLC%20Editor2/11%20Special%20instructions/WebHome/11_html_667c81877b8381e.gif?rev=1.1||alt="11_html_667c81877b8381e.gif" class="img-thumbnail"]],,[[image:11_html_667c81877b8381e.gif]],,
172 +|4D89H|The differential time constant (Td) is out of range.[[image:/bin/download/PLC%20Editor2/11%20Special%20instructions/WebHome/11_html_b1f11c46b396094.gif?rev=1.1||alt="11_html_b1f11c46b396094.gif" class="img-thumbnail"]],,[[image:11_html_b1f11c46b396094.gif]],,
173 173  |4D90H|The upper limit of CCPID output is less than the lower limit.
174 174  
175 175  **Example**