From version 6.3
edited by Joey123
on 2022/07/28 16:22
on 2022/07/28 16:22
Change comment:
Renamed from xwiki:PLC Editor2.2\.1 LX5V user manual.11.WebHome
Summary
-
Page properties (3 modified, 0 added, 0 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 -PLC Editor2.2\.1 LX5V user manual.WebHome 1 +PLC Editor2.1 User manual.2\.1 LX5V user manual.WebHome - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Joey1231 +XWiki.admin - Content
-
... ... @@ -311,6 +311,152 @@ 311 311 (% style="text-align:center" %) 312 312 [[image:11_html_599ccfa817c379fd.png||class="img-thumbnail"]] 313 313 314 +== **{{id name="_Toc30590"/}}{{id name="_Toc20656"/}}{{id name="_Toc13618"/}}PRUN/8 digit transmission (16-bit data)** == 315 + 316 +**PRUN(P)** 317 + 318 +After processing the device numbers of (s) and (d) with designated digits as octal numbers, transfer the data. 319 + 320 +-[PRUN (s) (d)] 321 + 322 +**Content, range and data type** 323 + 324 +(% class="table-bordered" %) 325 +|**Parameter**|**Content**|**Range**|**data**|**Data type (label)** 326 +|(s)|Digit designation*1|-|BIN16 bit|ANY16 327 +|(d)|Transfer destination device number*1|-|BIN16 bit|ANY16 328 + 329 +**Device used** 330 + 331 +(% class="table-bordered" %) 332 +|(% rowspan="2" %)**Instruction**|(% rowspan="2" %)**Parameter**|(% colspan="3" %)**Devices**|((( 333 +**Offset modification** 334 +)))|((( 335 +**Pulse extension** 336 +))) 337 +|**KnX**|**KnY**|**KnM**|**[D]**|**XXP** 338 +|(% rowspan="2" %)PRUN|Parameter 1|●| |●|●|● 339 +|Parameter 2| |●|●|●|● 340 + 341 +**Features** 342 + 343 +• 8-digit device → decimal device 344 + 345 +(% style="text-align:center" %) 346 +[[image:11_html_3c0c842b3d3c7a4.png||class="img-thumbnail"]] 347 + 348 +• Decimal digit device → octal digit device 349 + 350 +(% style="text-align:center" %) 351 +[[image:11_html_437032b41f24ad69.png||class="img-thumbnail"]] 352 + 353 +**Error code** 354 + 355 +(% class="table-bordered" %) 356 +|**Error code**|**Content** 357 +|4085H|When reading the specified device range exceeds the corresponding device range 358 +|4086H|When the specified device range for writing exceeds the range of the corresponding device 359 + 360 +**Example** 361 + 362 +(% style="text-align:center" %) 363 +[[image:11_html_e5ea991cf7b84dc0.png||class="img-thumbnail"]] 364 + 365 +As shown in the above Circuit program: 366 + 367 +X0 to X17 take the value of octal digits and pass it to the Devices corresponding to M. 368 + 369 +(% style="text-align:center" %) 370 +[[image:11_html_4d9c97b634dc29b1.png||class="img-thumbnail"]] 371 + 372 +== **{{id name="_Toc18093"/}}{{id name="_Toc173"/}}{{id name="_Toc26928"/}}TRH/Conversion of wet and dry bulb temperature and humidity** == 373 + 374 +**TRH** 375 + 376 +This instruction completes the conversion of dry bulb temperature, wet bulb temperature and corresponding humidity. 377 + 378 +-[TRH (d1) (s) (d2) (N)] 379 + 380 +**Content, range and data type** 381 + 382 +(% class="table-bordered" %) 383 +|**Parameter**|**Content**|**Range**|**Data type**|**Data type (label)** 384 +|(d1)|humidity|0 to 100|Single precision floating point|ANYREAL_32 385 +|(s)|Dry bulb temperature|-|Single precision floating point|ANYREAL_32 386 +|(d2)|Wet bulb temperature|-|Single precision floating point|ANYREAL_32 387 +|(N)|mode|0 to 1|Signed BIN 32 bit|ANY32 388 + 389 +**Device used** 390 + 391 +(% class="table-bordered" %) 392 +|(% rowspan="2" %)**Instruction**|(% rowspan="2" %)**Parameter**|(% colspan="11" %)**Devices**|((( 393 +**Offset** 394 + 395 +**modification** 396 +)))|((( 397 +**Pulse** 398 + 399 +**extension** 400 +))) 401 +|**KnX**|**KnY**|**KnM**|**KnS**|**T**|**C**|**D**|**R**|**SD**|**K**|**H**|**[D]**|**XXP** 402 +|(% rowspan="4" %)TRH|Parameter 1| | | | |●|●|●|●|●| | |●| 403 +|Parameter 2| | | | |●|●|●|●|●| | |●| 404 +|Parameter 3| | | | |●|●|●|●|●| | |●| 405 +|Parameter 4|●|●|●|●|●|●|●|●|●|●|●|●| 406 + 407 +**Features** 408 + 409 +(N)There are two modes to choose from: 410 + 411 +Mode 0: Calculate the corresponding humidity by wet bulb temperature and dry bulb temperature. 412 + 413 +Mode 1: Calculate the corresponding wet bulb temperature by dry bulb temperature and humidity. 414 + 415 +The conversion process formula is as follows: 416 + 417 +Assuming that the wet bulb temperature is A, the dry bulb temperature is B, and the corresponding current humidity is C, the three meet the following conditions: 418 + 419 +(% style="text-align:center" %) 420 +[[image:11_html_f9763504e639b084.gif||class="img-thumbnail"]] 421 + 422 +(% style="text-align:center" %) 423 +[[image:11_html_9eb43b8fba5e28f3.gif||class="img-thumbnail"]] 424 + 425 +(% style="text-align:center" %) 426 +[[image:11_html_f8a8e1f6b18e6e61.gif||class="img-thumbnail"]] 427 + 428 +(% style="text-align:center" %) 429 +[[image:11_html_c128b23414b3cae9.gif||class="img-thumbnail"]] 430 + 431 +**✎Note:** 432 + 433 +● The wet bulb temperature is not greater than the dry bulb temperature. When the two are the same, the humidity reaches the maximum 100%. 434 + 435 +● The unit of dry and wet bulb temperature is (℃). 436 + 437 +● The general value range of dry bulb is between 0 to 100℃, the command does not judge its range, so pay special attention when using this command. 438 + 439 +**Error code** 440 + 441 +(% class="table-bordered" %) 442 +|**Error code**|**Content** 443 +|(% rowspan="4" %)4084H|The value specified in (N) is out of the following range. 0 to 1 444 +|The value specified in (d1) is out of the following range. 0 to 100 445 +|A negative value is specified in (s). 446 +|A negative value is specified in (d2). 447 +|4085H|The output result of (d1)(s)(d2)(N) in the read application instruction exceeds the device range 448 +|4086H|The output result of (d1)(d2) in the writing application instruction exceeds the device range 449 + 450 +Dry and wet bulb humidity comparison table 451 + 452 +(% style="text-align:center" %) 453 +[[image:11_html_6cf6e76e6b1a3e12.png||class="img-thumbnail"]] 454 + 455 +**Example** 456 + 457 +(% style="text-align:center" %) 458 +[[image:11_html_4acab72ee19939e5.png||class="img-thumbnail"]] 459 + 314 314 == **CCPID instruction introduction manual** == 315 315 316 316 **Background and purpose**