Wiki source code of 02 PLC editor2 software help

Version 33.1 by Stone Wu on 2022/06/28 16:46

Show last authors
1 (((
2 = **1 Quick start** =
3 )))
4
5 This chapter briefly introduces the use of our PLC programming software (PLC editor2) to write a simple PLC control program and programming operations to help beginners get familiar with and master the operation of our programming software as soon as possible. The following are the development steps of PLC:
6
7 * Step 1: Start our PLC editor2 and enter the programming window.
8 * Step 2: Click "New" to pop up the "New Project" window, and set "PLC Series", "PLC Type" and "Program Language".
9 * Step 3: Click "Program" in the "Project Management" area to start writing the ladder diagram program.
10 * Step 4: Add instructions.
11 * Step 5: Save the program project (when the program has a specified save path, the software will save the current program regularly).
12 * Step 6: Compile the program.
13 * Step 7: Establish a communication connection with PLC.
14 * Step 8: Download the program to the PLC.
15 * Step 9: Start the PLC (RUN state).
16
17 == **Start the software** ==
18
19 After PLC editor 2 is correctly installed, click on PLC Editor2 in the Windows start menu to start the PLC programming software and enter the main programming screen, which is shown in the following figure:
20
21 (% style="text-align:center" %)
22 [[image:image-20220623161849-29.jpeg||height="861" width="1440"]]
23
24 == **Create a project** ==
25
26 After starting the programming environment, you first need to create a new project. Click "New" to pop up the "New Program" window, you can select or create a new project:
27
28 * PLC series
29 * PLC model
30 * PLC language
31
32 **To create a new project, please operate as shown in the figure below:**
33
34 1. Move the mouse to the upper left corner of the program, and click the "File" menu.
35 1. After clicking the "File"  menu, a new dialog box will pop up.
36
37 (% style="text-align:center" %)
38 [[image:image-20220623134722-3.jpeg||height="348" width="429"]]
39
40 (% start="3" %)
41 1. Select "PLC Series", "PLC Model" and "Program Language" through the drop-down box.
42 1. Click the "OK" button to create a new project.
43
44 (% style="text-align:center" %)
45 [[image:image-20220623134805-4.jpeg]]
46
47 In this example, we select a 5V type PLC, using ladder diagram as the programming language, after completing the steps of creating a new project, as shown in the following figure:
48
49 [[image:image-20220623135152-5.jpeg]]
50
51 **✎Note:** For the operation of specific project management function, please refer to the relevant chapters.
52
53 == **Add instructions** ==
54
55 1. When a project is created, expand the directory tree of "Project Manager".
56
57 (% style="text-align:center" %)
58 [[image:image-20220623135506-6.jpeg]]
59
60 (% start="2" %)
61 1. After expanding "Project Manager", click "Instructions" ->"Basic instructions", select the specific instruction,such as "LD".
62
63 (% style="text-align:center" %)
64 [[image:image-20220623140414-8.jpeg||height="598" width="268"]]
65
66 (% start="3" %)
67 1. Press and hold the mouse, select "LD]" and drag it to the right "Ladder Diagram (Write)"" input box, place it in the specified position, and release the left mouse button. Then you can input the parameters and click "OK".
68
69 (% style="text-align:center" %)
70 [[image:image-20220625113552-26.jpeg]]
71
72 (% style="text-align:center" %)
73 [[image:image-20220625113604-27.jpeg||height="184" width="916"]]
74
75 **✎Note: **
76
77 * In addition to the system default parameters, the input and output of some added commands are empty, and the user needs to input parameters or component addresses.
78 * If you want to add multiple instructions, repeat the above operation until all the instructions are added.
79
80 == **Compile program** ==
81
82 After the program is written, it needs to be compiled and saved, which can be achieved by pressing F4 on the keyboard or the Compile button in the program panel, as shown in the figure below.
83
84 (% style="text-align:center" %)
85 [[image:image-20220623144306-12.jpeg]]
86
87 If compiled successfully, it is shown as below.
88
89 (% style="text-align:center" %)
90 [[image:image-20220623144157-11.jpeg]]
91
92 If compilation fails, it is shown as below.
93
94 (% style="text-align:center" %)
95 [[image:image-20220623153633-19.jpeg]]
96
97 All errors will be displayed in the list box. You could select the specified error information, double-click the specified information with the left mouse button, and the system will automatically locate the error or warning position, which is convenient for you to debug the program.
98
99 **✎Note:** The program could be downloaded to the PLC only when the compilation is successful or there are no errors.
100
101 == **Communication test** ==
102
103 The communication test is to improve the connection stability of the PLC and PC, and avoid the loss of force majeure during the transmission process.
104
105 **Preparation steps:**
106
107 1. Open and run PLC Editor.
108 1. Click "Transfer Settings] of "Online" module above the program panel. As shown below:
109
110 (% style="text-align:center" %)
111 [[image:image-20220623145502-14.jpeg]]
112
113 (% start="3" %)
114 1. The "Transfersettings" dialog box pops up, when the "Detailed settings" is not checked, select the specified port, it is as shown in the figure below.
115
116 (% style="text-align:center" %)
117 [[image:image-20220623154113-20.jpeg]]
118
119 * **USB connection:** This download interface is only supported when using the PLC's USB port to download programs or monitor devices. If a USB device is currently connected, the software system defaults to the "PLC USB interface" button.
120 * **Ethernet configuration": **You could select the corresponding NIC and configure the IP address to connect the PLC with Ethernet function, or search the devices in the LAN by the device search function!
121 ** **✎Note:** Currently Ethernet is only supported by 5V-N series and 6V series.
122 * **Serial port (COM) connection**: Used when downloading programs or monitoring device using the PLC's round head (8-pin head).
123
124 (% start="4" %)
125 1. When the "Detailed Settings" option box is checked, the detailed settings window will pop up as below. You could set data according to their needs.
126
127 (% style="text-align:center" %)
128 [[image:image-20220623154122-21.jpeg]]
129
130 **✎Note:** The range of communication time check is 0 to 9999, and the number of repetitions is 0 to 5. Please do not exceed the limited range.
131
132 (% start="5" %)
133 1. After completing the settings, you could click the "Communication Test" or "OK" to perform a connection test.
134 1. If the test fails, the system will prompt as below.
135
136 (% style="text-align:center" %)
137 [[image:image-20220623153332-17.jpeg]]
138
139 (% start="7" %)
140 1. The connection is successful as shown in the figure below:
141
142 (% style="text-align:center" %)
143 [[image:image-20220623153337-18.jpeg]]
144
145 (% start="8" %)
146 1. After successful communication, you could click “Device Info“ to view the device information.
147
148 (% style="text-align:center" %)
149 [[image:image-20220623154456-22.jpeg]]
150
151 == **Download program** ==
152
153 **Work to be done before downloading:**
154
155 1. Open the compiler;
156 1. Create a new project and make the project compile successfully;
157 1. Install the corresponding PLC driver on the PC and connect the PLC and PC;
158 1. Complete the communication setting through the compiler.
159
160 **Start downloading**
161
162 * After completing the preparations, move the mouse to the Online module, and click the "Write to PLC" button to open the download setting window, as shown in the figure below:
163
164 (% style="text-align:center" %)
165 [[image:image-20220623155646-23.jpeg]]
166
167 * The online operation window is shown in the figure below:
168
169 (% style="text-align:center" %)
170 [[image:image-20220623160440-24.jpeg]]
171
172 * Click "Param+Prog (P)" button, and the system will automatically select the preset option in the message box. After the configuration is completed, click "Execute" . As shown below:
173
174 (% style="text-align:center" %)
175 [[image:image-20220623160446-25.jpeg]]
176
177 * After clicking "Execute", the system will automatically pop up a prompt window. Clicking "Yes" means stop the PLC operation and start downloading the PLC program. Clicking "No" means that the PLC will not be stopped, and the program will not be downloaded to the PLC. As shown below:
178
179 (% style="text-align:center" %)
180 [[image:image-20220623160453-26.jpeg]]
181
182 * After clicking "Yes", the download and compile window will start to run. As shown below:
183
184 (% style="text-align:center" %)
185 [[image:image-20220623160458-27.jpeg||height="619" width="742"]]
186
187 * When the progress bar in the download window completes the progress, the system will promt "Write to PLC(Complete)". As shown below:
188
189 (% style="text-align:center" %)
190 [[image:image-20220623160503-28.jpeg]]
191
192 = **2 Overall introduction** =
193
194 After the software is started, enter the main interface, as shown in the figure below:
195
196 [[image:image-20220623161945-30.jpeg]]
197
198 == **Toolbar** ==
199
200 Most of the functions of the software can be found here, which are divided into PLC, view and help.
201
202 [[image:image-20220625155137-1.jpeg]]
203
204 1. There are functions such as ladder diagram symbol, comment statement editing mode, compilation, communication function and encryption tool in the PLC classification, which will be explained in detail in the following chapters.
205 1. Functions such as each floating window and ladder diagram display scale can be enabled in the view classification.
206 1. The help of the software can be viewed in the help category, and the software version number information can be viewed through the about button of the category.
207
208 == **Project management** ==
209
210 It is used to create new programs, operate program pages or program blocks, and configure PLC parameters.
211
212 (% style="text-align:center" %)
213 [[image:image-20220623162814-32.jpeg]]
214
215 == **Ladder editing** ==
216
217 In short, it is the module for development. In this module, you could write programs, configure PLC and other development. At the same time, you could add, delete, modify and check PLC through this module.
218
219 (% style="text-align:center" %)
220 [[image:image-20220625113828-28.jpeg||height="197" width="983"]]
221
222 == **Floating windows** ==
223
224 It is used to display or realize a specific function, which will be explained in detail in the following chapters.
225
226 [[image:image-20220623163153-34.jpeg]]
227
228 **Status bar:** used to display the status of the PLC or program page.
229
230 (% style="text-align:center" %)
231 [[image:image-20220623163359-35.jpeg]]
232
233 = **3 PLC function menu** =
234
235 == **Clipboard** ==
236
237 Clipboard is a basic function of PLC Editor2 and has a very important function. This chapter will explain the basic description of the clipboard.
238
239 The clipboard has five functions: "Cut", "Copy", "Paste", "Undo" and "Redo".
240
241 (% style="text-align:center" %)
242 [[image:image-20220623170127-36.jpeg]]
243
244 * **Cut: **After selecting the ladder diagram, you could use the "Ctrl+X" command or the right mouse button to cut the selected data to the memory and switch to other places for use.
245 * **Copy:** After selecting the ladder diagram, you could use the "Ctrl+C" command or the right mouse button to copy the specified data.
246 * **Paste: **After selecting the ladder diagram, you can use the "Ctrl+V" command or the right mouse button to paste the specified data.
247 * **Undo:** Through "Ctrl+Z" or the right mouse button, the event operated by the user can be rolled back. Only when the software is running continuously, and the cancellation cache will be cleared if you exit.
248 * **Redo: **Through the "Ctrl+Y" or the right mouse button, you could return to the previous action after canceling the event.
249
250 == **Ladder symbol** ==
251
252 PLC Eidtor provides powerful and complete functions in the menu bar, which can greatly improve programming efficiency, as shown in the following figure:
253
254 (% style="text-align:center" %)
255 [[image:image-20220623171113-37.jpeg||height="120" width="247"]]
256
257 **The following table is a detailed description of the ladder diagram.**
258
259 (% class="table-bordered" %)
260 |(% style="width:70px" %)**Image**|(% style="width:361px" %)**Instruction**|(% style="width:382px" %)**Command function description**|(% style="width:263px" %)**Hot key**
261 |(% style="width:70px" %)[[image:5V帮助文档_中性_html_17467c64c59b7dcc.jpg||height="35" width="35"]]|(% style="width:361px" %)LD AND|(% style="width:382px" %)Input series normally open |(% style="width:263px" %)F5
262 |(% style="width:70px" %)[[image:5V帮助文档_中性_html_78ee1c120297f15c.jpg||height="35" width="35"]]|(% style="width:361px" %)OR|(% style="width:382px" %)Input parallel normally open|(% style="width:263px" %)SHIFT+F5
263 |(% style="width:70px" %)[[image:5V帮助文档_中性_html_6d69b74c12b3d4ac.jpg||height="35" width="35"]]|(% style="width:361px" %)LDI ANI|(% style="width:382px" %)Input series normally close|(% style="width:263px" %)F6
264 |(% style="width:70px" %)[[image:5V帮助文档_中性_html_16ca0a4e28932a25.jpg||height="35" width="35"]]|(% style="width:361px" %)ORI|(% style="width:382px" %)Input parallel normally open|(% style="width:263px" %)SHIFT+F6
265 |(% style="width:70px" %)[[image:5V帮助文档_中性_html_91ad97fbb1766cde.jpg||height="35" width="35"]]|(% style="width:361px" %)OUT|(% style="width:382px" %)Ladder diagram output coil|(% style="width:263px" %)F7
266 |(% style="width:70px" %)[[image:5V帮助文档_中性_html_bb11bf59792412cb.jpg||height="35" width="35"]]|(% style="width:361px" %)CJ/CALL and other application instructions|(% style="width:382px" %)Inpuyt application instructions|(% style="width:263px" %)F8
267 |(% style="width:70px" %)[[image:5V帮助文档_中性_html_e11c169668fbc3d7.jpg||height="35" width="35"]]|(% style="width:361px" %) |(% style="width:382px" %)Ladder diagram input horizontal line|(% style="width:263px" %)F9
268 |(% style="width:70px" %)[[image:5V帮助文档_中性_html_25d3575219c37c40.jpg||height="35" width="35"]]|(% style="width:361px" %) |(% style="width:382px" %)Ladder diagram input vertical line|(% style="width:263px" %)F11
269 |(% style="width:70px" %)[[image:5V帮助文档_中性_html_e1fd81d831e4cc1e.jpg||height="35" width="35"]]|(% style="width:361px" %) |(% style="width:382px" %)Delete horizontal line in ladder diagram|(% style="width:263px" %)CTRL+F9
270 |(% style="width:70px" %)[[image:5V帮助文档_中性_html_50a964bc9aa2388f.jpg||height="35" width="35"]]|(% style="width:361px" %) |(% style="width:382px" %)Delete vertical line in ladder diagram|(% style="width:263px" %)CTRL+F11
271 |(% style="width:70px" %)[[image:5V帮助文档_中性_html_4c194d2b4c3e9166.jpg||height="35" width="35"]]|(% style="width:361px" %)LDP ANP|(% style="width:382px" %)Input series rising edge pulse|(% style="width:263px" %)SHIFT+F7
272 |(% style="width:70px" %)[[image:5V帮助文档_中性_html_4e945174029d8824.jpg||height="35" width="35"]]|(% style="width:361px" %)LDF ANF|(% style="width:382px" %)Input series falling edge pulse|(% style="width:263px" %)SHIFT+F8
273 |(% style="width:70px" %)[[image:5V帮助文档_中性_html_94c5f7c4566eeb6e.jpg||height="35" width="35"]]|(% style="width:361px" %)ORP|(% style="width:382px" %)Input parallel rising edge pulse|(% style="width:263px" %)CTRL+ALT+F7
274 |(% style="width:70px" %)[[image:5V帮助文档_中性_html_fe027a1353a855e2.jpg||height="35" width="35"]]|(% style="width:361px" %)ORF|(% style="width:382px" %)Input parallel falling edge pulse|(% style="width:263px" %)CTRL+ALT+F8
275 |(% style="width:70px" %)[[image:5V帮助文档_中性_html_8213f80a4dec5ecc.jpg||height="35" width="35"]]|(% style="width:361px" %)INV|(% style="width:382px" %)Invert the result of the operation|(% style="width:263px" %)CTRL+ALT+F11
276 |(% style="width:70px" %)[[image:5V帮助文档_中性_html_bd63cbbc541dc1c9.png||height="35" width="35"]]|(% style="width:361px" %) |(% style="width:382px" %)Line segment input|(% style="width:263px" %)SHIFT+F9
277 |(% style="width:70px" %)[[image:5V帮助文档_中性_html_fb82ee5fc2b94c23.png||height="42" width="35"]]|(% style="width:361px" %) |(% style="width:382px" %)Line segment deletion|(% style="width:263px" %)SHIFT+F11
278 |(% style="width:70px" %)[[image:5V帮助文档_中性_html_236aac83ad0c365e.png||height="37" width="35"]]|(% style="width:361px" %)MEP|(% style="width:382px" %)Rising edge pulsing of operation results|(% style="width:263px" %)ALT+F5
279 |(% style="width:70px" %)[[image:5V帮助文档_中性_html_fc7bf55c55a8fc75.png||height="35" width="35"]]|(% style="width:361px" %)MEF|(% style="width:382px" %)Falling edge pulsing of operation results|(% style="width:263px" %)CTRL+ALT+F5
280
281 == **Comment&statement** ==
282
283 Editing comments or statement is mainly to comment the code in the project to better interpret the project.
284
285 As shown in the figure below, it enters the editing state.
286
287 (% style="text-align:center" %)
288 [[image:image-20220623172114-38.jpeg||height="129" width="125"]]
289
290 === **Edit comment** ===
291
292 Function: Comment on the device.
293
294 Prerequisite: devices are required on the ladder diagram.
295
296 Step:
297
298 1. Click the "Comment" button, when the button color becomes darker, it will enter the editing state.
299 1. After successfully entering the edit comment state, move the mouse to the code segment specified by you, and double-click the target area with the left button, and the "Comment Edit” window will pop up.
300 1. At this time, you could enter the specified comment in the column input box.
301 1. After editing the comment, click “Execute" to save it.
302
303 **✎Note:** The comment can be edited up to 128 characters, and the alias can be edited up to 8 characters.
304
305 (% style="text-align:center" %)
306 [[image:image-20220623172401-39.jpeg]]
307
308 **Result:**
309
310 (% style="text-align:center" %)
311 [[image:image-20220623172710-40.jpeg]]
312
313 === **Edit statement** ===
314
315 Function: Annotate the ladder diagram block.
316
317 **Step:**
318
319 1. Click the "Statement" button, when the button color becomes darker, it will enter the editing state.
320 1. After successfully entering the edit statement state, move the mouse to the code segment specified by you, and double-click the target area with the left button, and the "Statement Edit" window will pop up.
321 1. At this time, you could enter the specified statement in the previous input box.
322 1. After editing the statement, click "Execute" to save it.
323
324 **✎Note:** The statement line can edit up to 64 characters, and the statement can be downloaded to the PLC when downloading the ladder diagram.
325
326 (% style="text-align:center" %)
327 [[image:image-20220623172907-41.jpeg]]
328
329 **Result:**
330
331 (% style="text-align:center" %)
332 [[image:image-20220623172913-42.jpeg]]
333
334 == **Program compilation** ==
335
336 This chapter mainly introduces the program compilation function.
337
338 The program compilation menu has three functions, including compile, switch, and compile all, as shown in the figure below:
339
340 (% style="text-align:center" %)
341 [[image:image-20220624090820-2.jpeg]]
342
343 === **Compile** ===
344
345 Function: Refers to the form of converting the ladder diagram (program) of the current program page into the instruction list (IL).
346
347 Steps: After compiling the ladder diagram, click compile or use the hot key F4.
348
349 Results:
350
351 * Compiling correctly will prompt that the compilation is successful.
352
353 (% style="text-align:center" %)
354 [[image:image-20220624091026-3.jpeg]]
355
356 * Failure will prompt compilation failure. Locate the error and go to the information output window. You coulc modify the ladder diagram according to the prompts.
357
358 (% style="text-align:center" %)
359 [[image:image-20220624091132-4.jpeg||height="729" width="752"]]
360
361 (% style="text-align:center" %)
362 [[image:image-20220624091200-5.jpeg||height="214" width="1000"]]
363
364 * Double coil inspection, manifested in the form of warning.
365
366 (% style="text-align:center" %)
367 [[image:image-20220624092222-6.png||height="244" width="618"]]
368
369 === **Switch** ===
370
371 Function: refers to switching the current program page between the ladder diagram interface and the instruction list (IL) interface.
372
373 Steps: Click the switch button on the program page interface.
374
375 Results:
376
377 * In the compiled program page, click to switch to the instruction list interface.
378
379 (% style="text-align:center" %)
380 [[image:image-20220624093016-7.jpeg]]
381
382 * In the uncompiled program page, the prompt "TheI current ladder diagram is not compiledI. Do you want to abandon the current ladder diagram?" Click "Yes" to abandon the editing ladder diagram and convert it to the instruction list, click "No" not to switch.
383
384 (% style="text-align:center" %)
385 [[image:image-20220624094410-9.jpeg||height="380" width="946"]]
386
387 === **Compile all** ===
388
389 Function: Refers to converting the ladder diagram of all programs under the current project into the form of instruction list (IL).
390
391 Steps: Click the compile all button or use the shortcut key Ctrl+F4.
392
393 Expected: As long as there is a compilation error, it will prompt compilation failure, and only when all compilation succeeds will it prompt compilation success.
394
395 (% style="text-align:center" %)
396 [[image:image-20220624095005-10.jpeg]]
397
398 == **Program mode** ==
399
400 === **Monitor mode** ===
401
402 Function: monitor the value of the devices on the ladder diagram, modify and debug the program.
403
404 **Step:**
405
406 * Connect to the PLC and switch to monitoring mode.
407
408 [[image:image-20220624095815-11.jpeg]]
409
410 1. Right-click the menu, click "Debug" to modify the value of the device.
411
412 (% style="text-align:center" %)
413 [[image:image-20220624095855-12.jpeg]]
414
415 * Click the ON, OFF, or ON/OFF inversion to set the device.
416
417 (% style="text-align:center" %)
418 [[image:image-20220624100037-13.jpeg]]
419
420 === **Monitor edit** ===
421
422 PLC Editor2 provides the "Monitor edit" function. You could edit ladder program in the state of monitoring it.
423
424 Steps:
425
426 * Connect to PLC and switch to "Monitor edit" mode.
427
428 (% style="text-align:center" %)
429 [[image:image-20220624101413-14.jpeg]]
430
431 * Modify ladder diagram
432
433 (% style="text-align:center" %)
434 [[image:image-20220624101446-15.jpeg]]
435
436 * Compile the ladder diagram
437
438 (% style="text-align:center" %)
439 [[image:image-20220624101510-16.jpeg]]
440
441 * After the compilation, download it to PLC.
442
443 (% style="text-align:center" %)
444 [[image:image-20220624101609-17.jpeg]]
445
446 **✎Note:** The firmware version requires above v2.000 version.
447
448 == **Online** ==
449
450 The online menu provdes rich fucntions. It is mainly divided into 10 parts: Transfer settings, Read from PLC,Write to PLC, Checksum PLC, PLC Diagnosis, Remote operation, Device monitor, Module monitoring, Clear PLC memory, and PLC clock set.
451
452 (% style="text-align:center" %)
453 [[image:image-20220624103113-18.jpeg]]
454
455 === **Transfer settings** ===
456
457 Function: The main purpose is to improve the stability of the PLC and PC, and to avoid force majeure problems during transmission that could lead to losses.
458
459 **Steps:**
460
461 Open PLC Editor2, and click "Online" ->"Transfer Settings". As shown below:
462
463 (% style="text-align:center" %)
464 [[image:image-20220624103242-19.jpeg]]
465
466 "Transfer setting" dialog box will pop up. When using USB connection, select the specified port, it is as shown in the figure below.
467
468 (% style="text-align:center" %)
469 [[image:image-20220624103637-20.jpeg]]
470
471 When using Ethernet configuration, you could click "Devices research" to select the corresponding NIC and configure the IP address to connect the PLC with Ethernet function,
472
473 **✎Note:** Currently Ethernet configuration is only supported by 5V-N series and 6V series.
474
475 (% style="text-align:center" %)
476 [[image:image-20220624105239-21.jpeg]]
477
478 Click "Devices research" to pop up a search page, as shown below.
479
480 (% style="text-align:center" %)
481 [[image:image-20220624105429-22.jpeg||height="367" width="627"]]
482
483 **Description: **Clicking "Device search", it will automatically search for all PLC devices supporting Ethernet in the network segment matching subnet mask, i.e., the host computor and PLC must be in the same subnet to be recognized.
484 **The subnet mask matches the network segment:**
485
486 * If the IP of this machine is 192.168.56.237 and the subnet mask is 255.255.255.0, the PLC within the 192.168.56 network segment will be searched.
487 * If the IP of this machine is 172.16.56.1 and the subnet mask is 255.255.0.0, the PLC in the 172.16 network segment will be searched.
488 * If the IP of this machine is 10.244.56.9 and the subnet mask is 255.0.0.0, then the PLC in the 10 network segment will be searched.
489
490 **✎Note:** The NIC used for the IP search function is the NIC selected by the user of the NIC selection interface.
491 **Use:** Click "Device search" to search for devices in the LAN, and the searched devices are displayed on the interface. Selecting the corresponding line and clicking the "OK", the corresponding IP information will be displayed in the IP address input box of the Ethernet configuration. Please refer to the PLC programming manual for the specific PC network address configuration.
492
493 When using the serial port to connect, select the specified port and check the "Detailed setting", the detailed settings window will pop up as below.
494
495 (% style="text-align:center" %)
496 [[image:image-20220625114042-29.jpeg]]
497
498 You could set the data according to their needs.
499
500 **✎Note: **The range of communication time check is 0 to 9999, and the number of repetitions is 0 to 5. Please do not exceed the limited range.
501
502 After completing the settings, you could click the "Communication Test" or "OK" to perform a connection test.
503
504 If the test fails, the system will prompt as below.
505
506 (% style="text-align:center" %)
507 [[image:image-20220624111448-24.jpeg]]
508
509 Successful connection is shown as below.
510
511 (% style="text-align:center" %)
512 [[image:image-20220624111451-25.jpeg||height="186" width="285"]]
513
514 After successful communication, you can click "Device Info" to view the device information.
515
516 (% style="text-align:center" %)
517 [[image:image-20220624111617-26.jpeg]]
518
519 === **Read from PLC** ===
520
521 **Function: **Upload the data in the series PLC to the software through the communication line.
522
523 (% style="text-align:center" %)
524 [[image:image-20220624114311-27.jpeg]]
525
526 **Interface introduction:**
527
528 * **Para + program: **Upload parameters and programs from the PLC to the software.
529 * **Select all:** Upload parameters, programs, comments, devices memory area settings and electronic cam tables from the PLC to the software.
530 * **Cancel all select:** Cancel all selections.
531 * **Execute: **Start the upload operation.
532 * **Stop: **Stop the upload operation.
533 * **Close:** Exit the current window.
534 * **Execute (upload):** Upload the data of the lower computer to the software.
535 * **Display/Hide: **Display/hide the upload progress and other information, as shown in the figure below:
536
537 (% style="text-align:center" %)
538 [[image:image-20220624114427-28.jpeg]]
539
540 **Steps:**
541
542 Check the data items that need to be uploaded.
543
544 * If the selected data item is device memory, you could click "set" to set the title of the uploaded device memory and the range of the device to be uploaded.
545
546 [[image:image-20220624114632-29.jpeg]]
547
548 * If the selected data item is electronic cam table, you could click "set" to set the title of the uploaded electronic cam table and the uploaded cam table.
549
550 (% style="text-align:center" %)
551 [[image:image-20220624114647-30.jpeg]]
552
553 Click "Execute" to start uploading. At this time, the PLC needs to be in the stop state.
554
555 (% style="text-align:center" %)
556 [[image:image-20220624114918-31.jpeg]]
557
558 Keep communication and wait for the upload to complete.
559
560 (% style="text-align:center" %)
561 [[image:image-20220624114941-32.jpeg]]
562
563 === **Write to PLC** ===
564
565 **Function: **Download the ladder diagram program or other configuration to the PLC.
566
567 (% style="text-align:center" %)
568 [[image:image-20220624115206-33.jpeg]]
569
570 **Interface introduction:**
571
572 * **Para + program:** Download parameters and programs to the PLC.
573 * **Select all: **Download parameters, programs, comments, and devices memory area settings to the PLC.
574 * **Cancel all selections:** Cancel all selections.
575 * **Execute: **start the download operation.
576 * **Stop: **stop the download operation.
577 * **Close:** Exit the current window.
578 * **Calculated size:** To calculate the number of steps of the ladder diagram, the size of the downloaded file and the size of the comment, it needs to be connected to the PLC.
579 * **Display/Hide:** Display/hide the download progress and other information, as shown in the figure below.
580
581 (% style="text-align:center" %)
582 [[image:image-20220624115419-34.jpeg]]
583
584 **Step:**
585
586 Check the data items that need to be downloaded.
587
588 * If the selected data item is device memory, you could click "set" to set the title of the uploaded device memory and the range of the device to be downloaded.
589
590 (% style="text-align:center" %)
591 [[image:image-20220624115440-35.jpeg]]
592
593 The PLC needs to be in the stop state when downloading.
594
595 (% style="text-align:center" %)
596 [[image:image-20220624115451-36.jpeg]]
597
598 Keep communication and wait for the downpload to complete.
599
600 (% style="text-align:center" %)
601 [[image:image-20220624115455-37.jpeg]]
602
603 === **Device monitor** ===
604
605 **Function: **You can view and modify PLC register values and expansion module values online. Click this item to pop up the interface as shown in the figure below.
606
607 [[image:image-20220624134515-1.jpeg]]
608
609 **Interface description:**
610
611 * Monitoring start: start the current monitoring, the value of the register can be viewed or modified.
612 * End of monitoring: End the current monitoring, the value of the register cannot be viewed or modified.
613 * Edit current value: After clicking, a dialog box named "Modify device value" will pop up, and you could modify it.
614 * Close: Close the "Device Monitor” interface.
615
616 **Step:**
617
618 * Click "device monitor" to open the interface.
619
620 (% style="text-align:center" %)
621 [[image:image-20220624135018-2.jpeg]]
622
623 * Click "monitoring start" button under the premise of communicating with the PLC.
624
625 (% style="text-align:center" %)
626 [[image:image-20220624135057-3.jpeg]]
627
628 * The devices can be monitored by modifying the monitoring form, display, numerial and bit order .
629
630 (% style="text-align:center" %)
631 [[image:image-20220624135102-4.jpeg]]
632
633 * Switch device, search device and switch to monitor buffer memory.
634
635 [[image:image-20220624135106-5.jpeg]]
636
637 === **Clear PLC memory** ===
638
639 **Function**: Clear the data of the PLC
640
641 (% style="text-align:center" %)
642 [[image:image-20220624135402-6.jpeg]]
643
644 **Step:**
645
646 1. Before clearing the PLC memory, the PLC needs to be in the stop state.
647 1. Check the data object. If the PLC memory is checked, it includes but is not limited to data devicess, bit devicess and special devicess.
648 1. Click "Execution" and wait for the PLC to clear the data.
649
650 === **PLC clock set** ===
651
652 **Function:** Set the PLC clock. You could customize the internal time of the PLC to achieve the purpose of accurate calculation.
653
654 Click “ PLC clock set" to open the clock setting interface.
655
656 (% style="text-align:center" %)
657 [[image:image-20220624143649-1.jpeg]]
658
659 **Explanation:**
660
661 * Connection: Display the information of the currently PLC, read the parameters of this PLC, and cannot be changed.
662 * Time and calendar area: you can easily select time information and match freely.
663 * Read PC time: The software will automatically read the current PC time without manual calibration.
664 * Set time: After finishing the setting, click this button to save the current operation setting to the PLC.
665 * Close: Do not save the current operating data, and exit to close this window.
666
667 **Set time:**
668
669 1. Please ensure that the PLC and PC communicate normally. If it fails to communicate normally, please click "Transfer Settings" and put the PLC in the STOP state.
670 1. Click "PLC clock set" to open the time setting window.
671 1. Select the time required by the user in the time control panel or in the calendar panel.
672 1. The time interval of the year is 2000 to 2099; The interval of the month is January to December;
673 The time interval is from 0 o'clock to 23 o'clock; The partitions are from 0 minutes to 59 minutes; the second interval is from 0 seconds to 59 seconds.
674 1. You can also click [Get PC Time] to quickly match the current time (provided that the PC time is accurate).
675 1. After completing the configuration, please click "Set time" to save, otherwise it will not be saved. Successful setting is shown below.
676
677 (% style="text-align:center" %)
678 [[image:image-20220624143711-2.jpeg]]
679
680 === **Remote operation** ===
681
682 **Function: **Remote operation can quickly change the state of the PLC online and control the switch of the PLC.
683
684 (% style="text-align:center" %)
685 [[image:image-20220624144217-3.jpeg]]
686
687 === **PLC diagnostics** ===
688
689 **Function: **PLC diagnostics will monitor the errors generated by PLC in real time and reflect them in the table. You could view the summary of the error, the cause and the treatment method through this interface. If it is a problem with the ladder diagram, click Error Jump to jump to the location where the error occurred.
690
691 (% style="text-align:center" %)
692 [[image:image-20220624144649-4.jpeg||height="465" width="819"]]
693
694 === **PLC checksum** ===
695
696 **Function:** You could select the items that need to be verified by the PLC, as shown in the figure below:
697
698 (% style="text-align:center" %)
699 [[image:image-20220624145100-5.jpeg]]
700
701 Compare the difference between the program in the current PC software and the program in the PLC, as shown in the figure below:
702
703 (% style="text-align:center" %)
704 [[image:image-20220624145157-6.jpeg]]
705
706 Double-click the list, and you could view the specific differences of the program, as shown in the following figure:
707
708 (% style="text-align:center" %)
709 [[image:image-20220624145325-7.jpeg]]
710
711 === **Module monitor** ===
712
713 **Function:** This function is used to monitor the BFM value of the module and modify the BFM data. According to the description information corresponding to the BFM, the user can understand the function of the BFM.
714
715 **Interface description:**
716
717 * **Customization: **Create a new module plan, and use the default data as the initial value of the module BFM,. You could edit the plan content on this basis.
718 * **Save:** Create a new module plan, and use the current module monitoring data as the initial value of the module's BFM, You could  edit the plan content on this basis.
719 * **Help: **Open the instruction manual of the module where you could find the detailed instructions for the module.
720 * **Refresh: **You can update the module information of the current PLC connection and refresh the module information list.
721 * **Working mode:**
722 ** Offline: Display all module models that can be connected to the current PLC model. You could view the module BFM information when the module is not connected, or open the module instruction file through the "Help" button;
723 ** Online: Display the module information of the current PLC connection in the module information list, and monitor/modify the BFM value of the module.
724
725 **Step:**
726
727 * Click "Module Monitor".
728
729 (% style="text-align:center" %)
730 [[image:image-20220624151636-8.jpeg]]
731
732 * Select the module you want to monitor to o view and modify the value.
733
734 (% style="text-align:center" %)
735 [[image:5V帮助文档_中性_html_70be57a90d675c22.png||height="453" width="1200" class="img-thumbnail"]]
736
737 == **Tool** ==
738
739 === **PLC encryption tool** ===
740
741 In the PLC Editor2, you could set a password for the PLC to maintain security. The PLC encryption tool can be set to "upload password", "download password", and "clock password" respectively.
742
743 **Explanation:** The three types of passwords are independent (you must use separate decryption when performing operations), and the set passwords can be the same or different which ensure the safety and independence of PLC. As shown below:
744
745 (% style="text-align:center" %)
746 [[image:image-20220624152122-9.jpeg]]
747
748 **Precautions for setting a password:**
749
750 * The setting steps of "upload password", "download password", and "clock password" are exactly the same (only the type needs to be customized by the user).
751 * The length of the password can only be 8 characters, no more or less than.
752 * When setting a new password, the first time password and the second confirmation password must be the same.
753 * When performing password operations, please ensure that the PLC and PC are in a normal connection state, and the PLC must be in the NOT RUN state (close the switch of the PLC panel).
754 * When the password is entered incorrectly for 5 times, the password is locked, and the password can be entered again only when the PLC is restarted after power off.
755
756 **Steps to set password:**
757
758 * Connect the PLC and PC normally, and run the compiler at the same time;
759 * Turn off the RUN of the PLC;
760 * Click "PLC Encryption Tool" in the "Tool" panel;
761 * After opening a new window, if the "old password" input box cannot be entered, it means that the PLC is not currently encrypted;
762 * Select the type of password that needs to be set, and click "Set". (The following PLC takes uploading password as an example)
763
764 (% style="text-align:center" %)
765 [[image:image-20220624153523-10.jpeg]]
766
767 * Please follow the instructions to fill in the correct password.
768 * If the password length is not enough, there will be a prompt as follows:
769
770 (% style="text-align:center" %)
771 [[image:image-20220624153725-11.jpeg]]
772
773 * If the secondary password is inconsistent, there will be a prompt as shown below:
774
775 (% style="text-align:center" %)
776 [[image:image-20220624153816-12.jpeg]]
777
778 1. If the password is successfully set, there will be a prompt as shown below:
779
780 (% style="text-align:center" %)
781 [[image:image-20220624153830-13.jpeg]]
782
783 **Clear password**
784
785 If the PLC does not have a password, ignore this description. If the PLC has a password, please enter the existing password if you need to clear the password. Please refer to the precautions for input errors more than 5 times.
786
787 (% style="text-align:center" %)
788 [[image:image-20220624154242-16.jpeg]]
789
790 **Steps to clear the password:**
791
792 * Connect the PLC and PC normally, and run the compiler at the same time;
793 * Turn off the RUN of the PLC;
794 * Click "PLC Encryption Tool" in the "Tool" panel;
795 * Select the PLC password to be cleared in "Type", and click "Clear".
796 * After opening a new window, please enter the specified password in the "Please enter password" area, and then click "Execute".
797 * If you input the wrong upload password, there will be a prompt as shown below:
798
799 (% style="text-align:center" %)
800 [[image:image-20220624154309-17.jpeg]]
801
802 * If the password is correct, there will be a prompt as shown below:
803
804 (% style="text-align:center" %)
805 [[image:image-20220624154314-18.jpeg]]
806
807 === **Project encryption tool** ===
808
809 In the PLC Editor2, you could set a password for the project file to maintain security. As shown below:
810
811 (% style="text-align:center" %)
812 [[image:image-20220624154810-19.jpeg]]
813
814 **Precautions for setting a password:**
815
816 * The length of the password can only be 8 characters, no more or less than.
817 * When setting a new password, the first time password and the second confirmation password must be the same.
818 * When the password is entered incorrectly for 5 times, the password is locked, and the password can be entered again only when the project file is reopened.
819
820 **Steps to set password:**
821
822 * Click "Project encryption tool" in the "Tool" panel;
823 * After opening a new window, if the "old password" input box cannot be entered, it means that the PLC is not currently encrypted;
824 * Select the password that needs to be entered, and click "Set".
825
826 (% style="text-align:center" %)
827 [[image:image-20220624155700-20.jpeg]]
828
829 * Please follow the instructions to fill in the correct password.
830 * If the password is not long enough, there will be a prompt as shown below:
831
832 (% style="text-align:center" %)
833 [[image:image-20220624155810-21.jpeg]]
834
835 * If the secondary password is inconsistent, there will be a prompt as shown below:
836
837 (% style="text-align:center" %)
838 [[image:image-20220624155815-22.jpeg]]
839
840 * If the password is successfully set, there will be a prompt as shown below:
841
842 (% style="text-align:center" %)
843 [[image:image-20220624155841-23.jpeg]]
844
845 **Clear password**
846
847 If the project does not have a password, ignore this description. If the project has a password, please enter the existing password if you need to clear the password. Please refer to the precautions for input errors more than 5 times.
848
849 (% style="text-align:center" %)
850 [[image:image-20220624155909-24.jpeg]]
851
852 **Steps to clear the password:**
853
854 * Click "PLC Encryption Tool" in the "Tool" panel, and click "Clear".
855 * After opening a new window, please enter the specified password in the "Please enter password" area, and then click "Execute".
856 * If you input the wrong upload password, there will be a prompt as shown below:
857
858 (% style="text-align:center" %)
859 [[image:image-20220624155915-25.jpeg]]
860
861 * If the password is correct, there will be a prompt as shown below:
862
863 (% style="text-align:center" %)
864 [[image:image-20220624155920-26.jpeg]]
865
866 === **USB download** ===
867
868 **Function:** Generate a bin file. You could use the file to download programs and other configurations through the HMI screen.
869
870 **Step:**
871
872 * Click on the U disk to download and open the interface.
873
874 (% style="text-align:center" %)
875 [[image:image-20220624161054-27.jpeg]]
876
877 * Check the items that need to be downloaded, set the communication port parameters, and select the location of the U disk.
878
879 (% style="text-align:center" %)
880 [[image:image-20220624161153-28.jpeg]]
881
882 * Click "Excute" to generate the bin file.
883 * Insert the U disk into the HMI screen to download.
884
885 === **Automatic backup** ===
886
887 **Function**: Back up project files. You could view and retrieve historical versions through this function.
888
889 **Step:**
890
891 * Open the saved file, click compile, compile all, close the project, switch historical version or switch program type after editing. You could see the historical version number increase by clicking on the automatic backup window.
892
893 (% style="text-align:center" %)
894 [[image:image-20220624162512-29.jpeg]]
895
896 * Click the remark information to add remarks to the historical version, and click "OK" save it.
897 * Check the version number, and click "switch to this version", it will close the current version and load the historical version, as shown in the figure below:
898
899 (% style="text-align:center" %)
900 [[image:image-20220624162515-30.jpeg]]
901
902 === **Generate download file** ===
903
904 **Function:** Generate a file for download only, and the file cannot be viewed and uploaded.
905
906 **Step:**
907
908 1. Compile all the program pages, click to generate the download file.
909 1. Select the path and file name.
910 1. Open the generated **.swcp2** file and click download.
911
912 (% style="text-align:center" %)
913 [[image:image-20220624163706-1.jpeg]]
914
915 === **Reset window layout** ===
916
917 **Function:** Restore all floating windows in the program to the default position.
918
919 **Steps: **Click the reset window layout button in the view.
920
921 Before reset:
922
923 (% style="text-align:center" %)
924 [[image:image-20220624163720-2.jpeg]]
925
926 After reset:
927
928 (% style="text-align:center" %)
929 [[image:image-20220624163725-3.jpeg]]
930
931 = **4 Program editing area** =
932
933 In the program editing area, the user can freely switch between the ladder diagram and the instruction list. The ladder diagram interface provides editing operations. The instruction list interface is only allowed to be viewed and cannot be modified.
934
935 == **Ladder work area** ==
936
937 **Insert a new row**
938
939 * Select the position where you want to insert the row +1.
940 * Click on the keyboard "Shift] + Insert" to insert a new row, or move the mouse to any position of the specified insertion row, right-click, select "Edit"->"Insert row above (shift+insert)".
941
942 (% style="text-align:center" %)
943 [[image:image-20220625091617-1.jpeg]]
944
945 **Insert the statement**
946
947 Select the position where you want to insert the row.
948
949 * Method 1: Use the keyboard shortcut: Shift+Ctrl+Insert.
950
951 (% style="text-align:center" %)
952 [[image:image-20220625092707-2.jpeg]]
953
954 * Method 2: Keyboard shortcut "Ctrl+F7".
955
956 (% style="text-align:center" %)
957 [[image:image-20220625092847-3.jpeg]]
958
959 * Method 3: Right-click, select "Edit"->"Insert Statement".
960
961 (% style="text-align:center" %)
962 [[image:image-20220625092929-4.jpeg]]
963
964 **Delete row**
965
966 (% style="text-align:center" %)
967 [[image:image-20220625093015-5.jpeg]]
968
969 Move the mouse to the row to be deleted; press and hold the left mouse button to select and move the row to be deleted (multiple rows are possible), the selected area will change color, and then click "Delete" on the keyboard.
970
971 (% style="text-align:center" %)
972 [[image:image-20220625093149-6.jpeg]]
973
974 You could also select the row to be deleted, right-click to select "edit"->"delete row".
975
976 (% style="text-align:center" %)
977 [[image:image-20220625093415-7.jpeg]]
978
979 **4. Delete the statement**
980
981 Same as row deletion.
982
983 **Insert column**
984
985 * Select the position where you want to insert the column.
986 * Click the keyboard "Ctrl+ Insert" to insert, or move the mouse to any position of the specified insertion row, and right-click, to select "Edit" -> "Inser colume to the left".
987
988 (% style="text-align:center" %)
989 [[image:image-20220625094524-8.jpeg]]
990
991 (% style="text-align:center" %)
992 [[image:image-20220625094809-10.jpeg]]
993
994 **Delete column**
995
996 1. Select the position of the column to be deleted.
997 1. Press "Ctrl+Delete" on the keyboard to delete the column, or move the mouse to any position of the specified inserted row, right-click, and directly select "Delete", or select "Edit"->"Delete row".
998
999 Before deleting:
1000
1001 (% style="text-align:center" %)
1002 [[image:image-20220625094823-11.jpeg]]
1003
1004 After deleting:
1005
1006 (% style="text-align:center" %)
1007 [[image:image-20220625094828-12.jpeg]]
1008
1009 **Copy and paste**
1010
1011 The copy and paste function could save time and reduce the time on repeated operations.
1012
1013 **Steps**
1014
1015 * Move the mouse to the ladder editing area.
1016 * Select the specified cell or drag the mouse to select an area.
1017
1018 (% style="text-align:center" %)
1019 [[image:5V帮助文档_中性_html_d5aa6c70c096349a.png||height="155" width="700" class="img-thumbnail"]]
1020
1021 * Use the "Copy" button of "Clipboard" in the "PLC Menu", or use the right mouse button to "Copy", or use the keyboard "Ctrl+C".
1022
1023 (% style="text-align:center" %)
1024 [[image:image-20220625095651-14.jpeg]]
1025
1026 * After completing the third operation, copy the specified area to the clipboard.
1027 * Move the mouse to the designated position to be pasted, click the "Paste" button on the "Clipboard", or use the ""PasteMove the mouse to the designated position to be pasted, click the "Paste" button on the "Clipboard", or use the "Paste" function of the right mouse button, or use the keyboard "Ctrl+V" to copy the specified data Copy to the specified location.
1028
1029 (% style="text-align:center" %)
1030 [[image:image-20220625095656-15.jpeg]]
1031
1032 **Delete and modify ladder diagram components**
1033
1034 Steps:
1035
1036 1. The ladder diagram can be modified only in the "Edit mode" state.
1037
1038 (% style="text-align:center" %)
1039 [[image:image-20220625100200-16.jpeg]]
1040
1041 (% start="2" %)
1042 1. Use the mouse to select the components that needs to be modified, and double-click the left button or press the "Enter" key on the keyboard.
1043 1. After performing step 2, the output instruction dialog box will pop up.
1044 1. Enter the instruction corresponding to the selected component into the dialog box.
1045 1. Click "Execute" to save the modification.
1046
1047 **✎Note: **
1048
1049 1. The modified instruction must be able to pass the correct instruction verification before it can be saved.
1050 1. The contact element that occupies a cell (normally open, normally closed, rising edge, falling edge, reverse, stepping) cannot modify each other with the comparison contact.
1051 1. All contact components cannot be modified mutually with coils or application instructions.
1052
1053 **Delete ladder diagram components**
1054
1055 Steps:
1056
1057 1. The ladder diagram can be deleted only in the "Edit mode" state.
1058 1. Use the mouse to select the component grid that needs to be deleted, left-click, and the selected part will be locked with a blue frame, and then you could press "Delete" on the keyboard to delete it.
1059 1. Batch delete: Move the mouse to the specified delete area, hold down the left mouse button and drag the mouse, and select cells in batches (cells will turn blue). After completing the selection, you could press "Delete" on the keyboard to delete it.
1060 1. Delete horizontal and vertical lines: In this special ladder diagram, you could perform step 2 or 3 to select the target first, and then click the "CF9" icon or "CF11" in the "Ladder symbol" function of the menu bar to execute the corresponding deletion.
1061
1062 **Enter ladder diagram instructions**
1063
1064 There are 5 ways to input ladder diagram instructions:
1065
1066 1. Direct input
1067 1. Input through instruction set
1068 1. Double-click cell
1069 1. Instruction help
1070 1. Ladder symbol/Shortcut
1071
1072 Direct input method
1073
1074 * Move the mouse and left-click the specified cell.
1075 * Directly use the keyboard to input the specified instruction, the system will automatically pop up the ladder diagram input box.
1076
1077 (% style="text-align:center" %)
1078 [[image:image-20220625102401-17.jpeg]]
1079
1080 * Enter the complete instructions and parameters in the dialog box.
1081 * Click "Execute" or the "Enter" button on the keyboard.
1082 * The system verifies the correctness of the input, and generates the graphic element represented by the instruction after the verification is correct.
1083 * If the instruction is wrong, the instruction help interface will pop up.
1084
1085 (% style="text-align:center" %)
1086 [[image:image-20220625102414-18.jpeg]]
1087
1088 Input through instruction set
1089
1090 1. Move the mouse to the [Project Management] interface on the left side of the window.
1091 1. Expand "Instruction Set" and open the instruction tree you need
1092 1. Select the instruction you need, and left-click and hold, drag it to the "ladder diagram writing area", and place it in the specified area.
1093 1. After completing step above, a "ladder input " will pop up, then input the correct operand.
1094 1. Click "Execute" or "Enter" on the keyboard.
1095
1096 (% style="text-align:center" %)
1097 [[image:image-20220625103448-19.jpeg]]
1098
1099 Double-click the cell
1100
1101 1. Move the mouse to the specified area and double-click the left button.
1102 1. "Ladder input" pops up, enter the correct command in the input box.
1103 1. Click "Execute" or the keyboard "Enter".
1104 1. If the instruction is wrong, the instruction help interface will pop up.
1105
1106 (% style="text-align:center" %)
1107 [[image:image-20220625104404-20.jpeg]]
1108
1109 Instruction help
1110
1111 1. Move the mouse to the designated area and double-click the left button to pop up “Ladder input”.
1112 1. Click “Help” to pop up “Instruction Help”。
1113 1. After selecting the instruction that needs to be entered, click the "Detail" button to pop up the "Instruction Wizard".
1114 1. The instruction guide interface selects the correct operand according to different instructions.
1115 1. After selecting the specified instruction, click "Execute" to save the data and complete the instruction input.
1116
1117 [[image:image-20220625105747-21.jpeg]]
1118
1119
1120 (% style="text-align:center" %)
1121 [[image:image-20220625105752-22.jpeg]]
1122
1123 Ladder symbol/shortcut
1124
1125 The ladder diagram symbol is located in the PLC menu, as shown in the figure below:
1126
1127 (% style="text-align:center" %)
1128 [[image:image-20220625105848-23.jpeg||height="161" width="336"]]
1129
1130 After selecting the cell, click "Ladder Symbol" in the menu, and enter the operand in the pop-up ladder diagram input box to complete the instruction input. If it is an application instruction, after clicking [[image:5V帮助文档_中性_html_1c8d975fb5bd8c.png]] on the panel, you must input the complete application instruction and its operands in the ladder diagram input box to complete the input instruction. You can also use the shortcut corresponding to the command (see the shortcut key list) to input, and the operation method is the same as the "ladder symbol".
1131
1132 After the instruction input is completed, click the "Execute" button in the ladder diagram input box and it will be displayed in the ladder diagram editing area.
1133
1134 **✎Note: **
1135
1136 1. Some instructions can only be input in the instruction list (IL) editor, but not in the ladder diagram, such as MPS, MPP, etc. When these instructions are directly input in the ladder diagram, no components will be generated.
1137 1. Since coils and application instructions represent the end of one line of the ladder diagram program, no other components can be input after these components.
1138 1. Since the vertical line occupies the space of two lines, when inputting the vertical line, if the corresponding position in the next line is just the middle part of other components, the vertical line cannot be input.
1139 1. The maximum number of input columns in the ladder diagram is 13 columns.
1140
1141 == **Instruction list work area** ==
1142
1143 Instruction list editor
1144
1145 In the PLC Editor, the program not only provides a ladder diagram editor, but also provides an instruction list interface. The instruction list interface is not editable and only allowed to be viewed. As shown below:
1146
1147 (% style="text-align:center" %)
1148 [[image:5V帮助文档_中性_html_550c5cb7f37a8b23.png||height="190" width="300" class="img-thumbnail"]]
1149
1150 * **Step number: **The step number indicates the position of the instruction in the program, which can be used to quickly locate the program and improve the readability of the program.
1151 * **Ladder diagram-instruction list switching:** If there is an error in the program logic, it cannot be switched.
1152
1153 == **Shortcut menu** ==
1154
1155 In the program editing area, click the right mouse button to pop up frequently used function buttons, which can greatly improve the developer's development efficiency.
1156
1157 (% style="text-align:center" %)
1158 [[image:image-20220625111835-24.jpeg]]
1159
1160 * **Undo:** Undo the current operation and roll back the previous step.
1161 * **Redo: **Roll back the undo operation.
1162 * **Cut:** Cut the selected content in the ladder diagram and put it on the clipboard.
1163 * **Copy: **Copy the selected content in the ladder diagram and put it on the clipboard.
1164 * **Paste:** Paste the data in the clipboard at the selected position in the ladder diagram. When there is no data in the clipboard, paste is not available.
1165 * **Delete:** Delete the selected content in ladder diagram.
1166 * **Compile:** Compile the current program page.
1167 * **Editing options:**
1168 ** Insert row: Insert an blank row in the current selected row in the ladder diagram.
1169 ** Insert statement: Insert a blank staement row in the current selected row in the ladder diagram.
1170 ** Delete row: Delete the currently selected row in the ladder diagram.
1171 ** Insert column to the left: In the ladder diagram, a blank node is added to the selected instruction, and other instructions move one space to the right.
1172 ** Delete column: In the ladder diagram, delete the currently selected instruction, and other instructions move one space to the left.
1173 * **Search:**
1174 ** Device search: open the search/replace window, the default is the device search page, if the selected instruction in the ladder diagram contains a device, the "search device" defaults to the selected instruction's device, and it will be empty if there is none.
1175 ** Instruction search: Open the search/replace window, the default is the command search page, if the command is selected in the ladder diagram, the "search command" defaults to the selected command, and it is empty if there is no command.
1176 ** String search: Open the search/replace window, the default is the string search page, if a string is selected in the ladder diagram, the "search string" defaults to the selected string, and it is empty if there is no string.
1177 * **View:**
1178 ** Comment display: In the ladder diagram, the comment of the device is displayed.
1179 ** Alias display: In the ladder diagram, display the alias of the device.
1180 * **Debugging:**
1181 ** Modify the current value: In the monitor mode (write mode is not available), open the device write dialog box. Modify the value of the device of the currently selected instruction.
1182
1183 = **5 Project management** =
1184
1185 == **Program** ==
1186
1187 MIAN is the default program page name for a new project. There can be multiple program pages in a project. Double-click the program page to open the ladder diagram editing area in the user area, and you could edit the program.
1188
1189 (% style="text-align:center" %)
1190 [[image:image-20220625134223-1.jpeg]]
1191
1192 **New program page:** select scan/event/subroutine/interrupt, right click"scan"->"new", you could open the new program window, as shown in the figure below:
1193
1194 (% style="text-align:center" %)
1195 [[image:5V帮助文档_中性_html_a8e9017d31a283f4.png||height="253" width="300" class="img-thumbnail"]]
1196
1197 (% style="text-align:center" %)
1198 [[image:image-20220625134350-3.jpeg]]
1199
1200 **Program page operations**: Right-click the program page with the mouse to perform corresponding operations.
1201
1202 (% style="text-align:center" %)
1203 [[image:image-20220625134542-5.jpeg]]
1204
1205 Delete: Delete the program page.
1206
1207 Rename: Rename the program page.
1208
1209 Program encryption: Encrypt and decrypt the program page.
1210
1211 * Encryption: select the program page to be encrypted and set the encryption password, After the encryption is executed, the program page is in the "encrypted" state, and the content of the program page is not displayed.
1212
1213 (% style="text-align:center" %)
1214 [[image:5-4.jpg]]
1215
1216 (% style="text-align:center" %)
1217 [[image:5-5.jpg]]
1218
1219 (% style="text-align:center" %)
1220 [[image:5-6.jpg]]
1221
1222 * Cancel encryption: After entering the correct password, cancel the encryption of the program page.
1223
1224 (% style="text-align:center" %)
1225 [[image:image-20220625140048-6.jpeg]]
1226
1227 (% style="text-align:center" %)
1228 [[image:image-20220625140150-7.jpeg]]
1229
1230 * Modify password: After entering the original program page password, set a new program page password.
1231
1232 (% style="text-align:center" %)
1233 [[image:image-20220625140231-9.jpeg]]
1234
1235 (% style="text-align:center" %)
1236 [[image:image-20220625140328-10.jpeg]]
1237
1238 * Display encrypted content: Display the encrypted program page content. This function is only used to temporarily display the content of the program page without canceling the encryption status of the program page, which is convenient for editing the encrypted program page.
1239
1240 (% style="text-align:center" %)
1241 [[image:5-11.jpg]]
1242
1243 (% style="text-align:center" %)
1244 [[image:image-20220625140706-11.jpeg]]
1245
1246 Set: Right-click it, and you could view the author, date of creation, and remarks on the program page.
1247
1248 (% style="text-align:center" %)
1249 [[image:image-20220625141015-13.jpeg]]
1250
1251 * Configuration: The time and interrupt program page can click the configuration button to set the trigger condition.
1252
1253 (% style="text-align:center" %)
1254 [[image:image-20220625142325-15.jpeg]]
1255
1256 Move up: Move the program page up, used to adjust the execution order of the program page.
1257
1258 [[image:5-15.jpg]] [[image:5-16.jpg]]
1259
1260 Move down: Move the program page down to adjust the execution order of the program page.
1261
1262 [[image:5-17.jpg]] [[image:5-18.jpg]]
1263
1264 == **Device comment** ==
1265
1266 Device comment module: A **.wcp2** file has one and only one module named "COMMENT" in "device comment".
1267
1268 Double-click "COMMENT" and shown as below.
1269
1270 [[image:image-20220625143125-16.jpeg]]
1271
1272 **Interface label description:**
1273
1274 * **Enter device name:** Input the correct device name and press "Enter" to confirm, the comment list will locate the input device and select it.
1275 * **The comment list is divided into 3 columns: **device name, device comment, and device alias. Click the comment list, and select the device row, and double-click the device comment or alias to pop up an edit box for editing. The device comment value allows 128 characters, and the device alias only allows input of 8 characters.
1276 * **Device interval selection: **Click to select the device interval and change the device displayed in the comment list. The blue device section indicates that the section is selected. The devices interval is as shown in the figure below:
1277
1278 (% style="text-align:center" %)
1279 [[image:image-20220625143652-17.jpeg]]
1280
1281 **Interface button description:**
1282
1283 * **Display commented devices:** The comment list displays all devices with comments or aliases.
1284 * **Import EXCEL:** select the ***.xls **file to be imported, and import all the correct device comments and aliases in the *.xls file into the software (supports *.csv file import).
1285 * **Export EXCEL: **Export and save all the devices information of edit devices comments or aliases as ***.xls** files to local disk.
1286
1287 == **Parameter** ==
1288
1289 You could set the latch range of the PLC devices and the COM port communications according to your needs. Click the "×" symbol in the upper right corner to close the dialog box and change without saving.
1290
1291 Double-click the "PLC Parameters" node and the interface is shown as below.
1292
1293 (% style="text-align:center" %)
1294 [[image:image-20220625144326-19.jpeg]]
1295
1296 **Interface button description:**
1297
1298 * Check: Check the configuration of the current settings, respectively check the "device latch", "COM1 " and "COM2". If the check fails, click the "OK" button to report an error.
1299 * Reset: Click this button to restore the default settings.
1300 * OK: Complete the correct PLC parameter change and set it.
1301 * Cancel: Cancel the PLC parameter setting and keep the parameter setting before the change.
1302
1303 **Device latch**
1304
1305 The address range of various types of registers including PLC is set in the devices. You could set parameters in the white squares in the picture table, but not the gray ones (cannot be modified). By modifying the data at the beginning and end of the latch, the latch range of the register can be modified, and the modified data range must be within the latch range.
1306
1307 (% style="text-align:center" %)
1308 [[image:image-20220625145833-20.jpeg]]
1309
1310 **COM1 settings**
1311
1312 (% style="text-align:center" %)
1313 [[image:image-20220625145902-21.jpeg]]
1314
1315 * Whether to set: Whether to enable the COM1 port configuration.
1316 * Baud rate: Select the data transmission rate.
1317 * Data bit: Select the data length.
1318 * Stop bit: Select the number of stop bits.
1319 * Parity: Select the number of parity.
1320 * Station No.: Set the station number, ranging from 1 to 47.
1321
1322 **COM2 settings**
1323
1324 (% style="text-align:center" %)
1325 [[image:image-20220625150016-22.jpeg]]
1326
1327 Whether to set: whether to enable the COM1 port configuration.
1328
1329 * **Communication settings**
1330 ** Baud rate: Select the data transmission rate.
1331 ** Data bit: Select the data length.
1332 ** Stop bit: Select the number of stop bits.
1333 ** Parity: Select the check digit.
1334 ** Timeout: Set the timeout time, ranging from 0 to 32767.
1335 ** Sending interval: Set the sending interval, ranging from 0 to 32767.
1336 ** Protocol: Select the communication protocol.
1337 * **Protocol related**
1338 ** Station No.: Set the station number. According to different protocols, the station number setting range is different.
1339 ** Whether to enable the start character: used to customize the protocol.
1340 ** Starter: set the end character for custom protocol.
1341 ** Whether to enable terminator: used to customize the protocol.
1342 ** Terminator: Set the terminator to customize the agreement.
1343 ** Timeout between characters: used to customize the protocol.
1344
1345 **Ethernet settngs**
1346
1347 (% style="text-align:center" %)
1348 [[image:image-20220625150721-23.jpeg]]
1349
1350 **✎Note:** Currently Ethernet configuration is only supported by 5V-N series and 6V series.
1351
1352 * **Communication settings**
1353 ** Whether to set: Whether to enable communication configuration of Ethernet setttings.
1354 ** Whether to enable PLC automatic configuration IP (DHCP) function: automatic configuration IP (DHCP) function. **(only supported by 6V series currently)**
1355 ** IP address: Configure the IP address of PLC
1356 ** Subnet mask: Configure the subnet mack of PLC
1357 ** Default gateway: Configure the default gateway of PLC
1358 * **Protocol related**
1359 ** Whether to set: Whether to enable the protocol configuration of Ethernet settings.
1360 ** Maximum number of connections supported by modbusTCP server: Number of simultaneous connections available for other modbusTCP clients. **(only supported by 5V-N series currently)**
1361
1362 **Basic imformation settngs**
1363
1364 (% style="text-align:center" %)
1365 [[image:image-20220625152250-24.jpeg]]
1366
1367 It is used to configure sonme basic imformation.
1368
1369 * Whether to set: Whether to enable the basic imformation setttings.
1370 * PLC name: Used to set the name of PLC. The maximum number of characters allowed to be entered is 32; the range of illegal characters not allowed to be entered: /%$@&=~~`^<>? :{}[],;! *. \'"|
1371
1372 **✎Note:**
1373
1374 * the first one is a space, and a space is also an illegal character.
1375 * Currently, only PLCs with Ethernet function (5V-N series and 6V series) are supported.
1376
1377 == **Device memory** ==
1378
1379 It is used to set the data of PLC data block when PLC is downloaded, and the data of the read PLC data block is displayed when PLC is uploaded.
1380
1381 New devices memory: Right-click and select the "device memory" → "New" to create a new device memory file (any character in the file name, up to 64 characters in length, and only one can be downloaded at a time). The interface is as follows:
1382
1383 [[image:image-20220625170448-1.jpeg]]
1384
1385 **Interface label description:**
1386
1387 * **Please enter:** Enter the device to be searched, and press "Enter" to locate the device to be searched.
1388 * **Device list:** Divided into 10 intervals: C, D, HSC, LC, M, R, S, T, V, Z.
1389
1390 (% style="text-align:center" %)
1391 [[image:image-20220625171055-2.jpeg]]
1392
1393 * **Device value display area**: Currently editing operations are prohibited.
1394
1395 (% style="text-align:center" %)
1396 [[image:image-20220625171109-3.jpeg]]
1397
1398 * **Cell format:** 7 data formats: binary, decimal, hexadecimal, octal, real number, character string, ASCII code. One format and one color:
1399 ** Binary: red
1400 ** Octal : pink
1401 ** Decimal: blue
1402 ** Hexadecimal: brown
1403 ** Real number: orange
1404 ** Character string: cyan
1405 ** ASCII code: green
1406
1407 (% style="text-align:center" %)
1408 [[image:image-20220627105818-1.jpeg]]
1409
1410 * **The data can be expressed in size:** 16 bits and 32 bits.
1411 * **The data size that each format can represent when the length is 16 bits:**
1412 ** Binary: 0000000000000000 to 1111111111111111;
1413 ** Octal: 0 to 1777777;
1414 ** Decimal: -32768 to 32767;
1415 ** Hexadecimal: 0 to FFFF;
1416 ** String: the size of 2 characters in length;
1417 ** ASCII: 2 ASCII code values.
1418 * **The data size that each format can represent when the length is 32 bits:**
1419 ** Binary: 00000000 00000000 00000000 00000000 to 11111111 11111111 11111111 11111111;
1420 ** Octal: 0 to 37777777777;
1421 ** Decimal: -2147483648 to 2147483647;
1422 ** Hexadecimal: 0 to FFFF FFFF FFFF FFFF;
1423 ** String: the size of the length of 4 strings;
1424 ** ASCII: 4 ASCII code values;
1425 ** Real number: ±1.175495E-38 to ±3.402823E+38.
1426
1427 == **Electronic cam** ==
1428
1429 In the project management window, right-click “electronic cam table” to create a new electronic cam table (ECAM table).
1430
1431 [[image:5-31.jpg]] [[image:5-32.jpg]]
1432
1433 Open the ECAM interface and set the data.
1434
1435 (% style="text-align:center" %)
1436 [[image:image-20220627110623-2.jpeg||height="723" width="1226"]]
1437
1438 Click the parameter setting to set the parameters, such as the starting device, which indicates the starting position of the download time.
1439
1440 (% style="text-align:center" %)
1441 [[image:image-20220627110657-3.jpeg]]
1442
1443 The ECAM table information written by other programs can be imported into the ECAM table through import and export.
1444
1445 You could download the ECAM to the PLC.
1446
1447 == **Instructions** ==
1448
1449 Available instructions are as follows: all instructions; basic instructions; step ladder instruction; program flow; transfer and compare; Arithmetic; cycle and shift; data processing; high-spped processing; common instruction; peripheral device IO; peripheral device SER; floating; contact compare; high-speed pulse output; clock calculation; floating contact comparison; data table; data block; communication instruction; electrionic CAM; other instructions; string control; Ethernet.
1450
1451 (% style="text-align:center" %)
1452 [[image:image-20220627112121-4.jpeg]]
1453
1454 == **PLCLINK table** ==
1455
1456 **New table: **After create a new table, you could view "PLCLINK" in project manager window. Right-click it to create a PLCLINK table.
1457
1458 [[image:image-20220627113003-5.jpeg]]
1459
1460 (% class="wikigeneratedid" %)
1461 **Starting address settings:** You can select D or R device as the area for storing PLCLINK table contents, and edit the starting device address, which will occupy 22+5*n devices starting from this device. This occupancy information reflects the tabular operation in the list of device used.
1462 **New command**: Click "New command" to generate a PLCLINK command.
1463
1464 (% style="text-align:center" %)
1465 [[image:image-20220627115343-6.jpeg]]
1466
1467 (% class="wikigeneratedid" %)
1468 **Delete: **Select the PLCLINK command to be deleted to delete the command.
1469 **Modify station NO.:** You select the station number in the drop-list. The station numbers of station No.1 and station number No.2 cannot be the same. Range: 1 to 31.
1470
1471 (% style="text-align:center" %)
1472 [[image:image-20220627115946-7.jpeg||height="638" width="399"]]
1473
1474 (% class="wikigeneratedid" %)
1475 **Modify device name:** Select device name in the drop-list, note that the soft component type of station number (1) and station number (2) need to be the same.
1476 **Modify device address:** Edit the start address edit box and enter the value within the range of the device.
1477 **Modify the number of device:** Edit the number of device edit box, and enter the number of device.The number of double-word device ranges from 1 to 64. Device ranges from 1 to 128, and bit device ranges from 1 to 1024.
1478 **Modify instruction enable status:** Click "Station No. Enable" to edit the parameters of the two stations of this instruction. The master station is always enabled and cannot be modified.
1479
1480 * For example:
1481 ** click "New Command" to create a PLCLINK command.
1482 ** Sstation NO.1 is selected as 2, station number NO.2 is selected as 3.
1483 ** Click 'Station NO. Enable". If station number NO.1 is checked to enable, but station NO.2 is not checked to enable, the command enable is invalid. Only when both station numbers are checked to enable, the command enable is valid.
1484
1485 (% style="text-align:center" %)
1486 [[image:image-20220627134639-8.jpeg]]
1487
1488 (% class="wikigeneratedid" %)
1489 **PLCLINK operation**
1490
1491 * **Check: **Check whether the data of PLCLINK is legal.
1492 * **Save:** Enabled under the condition that the program is consistent in monitoring mode, and it will compare once automatically when entering.
1493 * **Check Slave:** Send command to PLC to check slave information.
1494 * **Monitor Read:** Get PLCLINK table information from PLC.
1495 * **Monitor Write:** Write PLCLINK table to PLC
1496
1497 == **Ethernet** ==
1498
1499 Interface: Click "Project manager" -> "Extened funtion", and right-click "Ethernet" to open the "New-Ethernet configuration" window.
1500
1501 (% style="text-align:center" %)
1502 [[image:image-20220627141744-9.jpeg]]
1503
1504 (% class="wikigeneratedid" %)
1505 Description: Ethernet socket configuration, with Ethernet SOC series instruction can implement modbusTCP client, TCP free protocol and UDP free protocol.
1506 Through the configuration of the corresponding properties to achieve the corresponding functions, and download the program to the PLC through the download interface. Please refer to the PLC programming manual for specific usage rules and configuration methods
1507
1508 (% class="wikigeneratedid" %)
1509 The introdution of parameters:
1510
1511 (% style="text-align:center" %)
1512 [[image:image-20220627153819-1.jpeg]]
1513
1514 * **Whethern to enable: **Whethern to enable the Ethernet configuration
1515 * **socket ID: **The number of socket supports a total of 6 ranging from K0 to K5. The socket ID is used to specify the link. Each ID is used for one link and cannot be defined repeatedly.
1516 * **Communication protocal: **TCP protocol and UDP proctocol are supported.
1517 * **Operating mode: **For TCP, you could sleect client and server. For UDP, this does not work.
1518 * **Local port:**
1519 ** For TCP client mode, the local port will be automatically allocated by PLC without setting.
1520 ** For TCP server mode, the local port could be set within the range of 1 to 65,535. Port 502 is used by internal modbusTCP and cannot be set.
1521 ** For UDP mode, the local port could be set within the range of 1 to 65,535. Port 1092 is used by scanning protocol and cannot be set.
1522 * **Target ID: **Valid in TCP client mode or UDP mode, specifying the peer device IP to be linked.
1523 * **Target port: **Valid in TCP client mode or UDP mode, specifying the peer device port number to be linked.
1524 * **Receive timeout: **After PLC sending data, if the response of the peer device exceeds this timeout, the network is considered abnormal and the error flag bit is set.
1525 * **TCP keep-alive mechanism: **When TCP protocal is used for communication, If the communication line is idle in most cases and only a small amount of data is sent and received, but the link needs to be kept open, or disconnected in time in case of a drop, crash or forced termination of the process at the communication end, you can use the keep-alive mechanism for communication.
1526
1527 = **6 Output window** =
1528
1529 == **Information output** ==
1530
1531 **Information output window: **Provide users with the results after the software performs operations including the execution result information of the three operations of compiling, communication, and switch.
1532
1533 (% style="text-align:center" %)
1534 [[image:image-20220628142118-1.jpeg]]
1535
1536 If there is an error in the program, the error will be listed in the "Information output" module at the bottom of the ladder diagram. Select the specified error item, and double-click to locate the error position of the ladder diagram.
1537
1538 = **7 Search&Replace** =
1539
1540 **Search and replace function: **Similar to the search and replace function of OFFICE, it can locate the data block specified by the user in a large amount of data, or perform batch addition, deletion, modification, and check, which can greatly improve efficiency.
1541
1542 **How to use: **Open the main program, after creating a new project, click “Ctrl+F” on the keyboard to pop up the search and replace interface, as shown in the following figure:
1543
1544 (% style="text-align:center" %)
1545 [[image:image-20220628142601-2.jpeg]]
1546
1547 Buttons are divided into 4 categories: devices, instruction, string, and result, as shown in the figure above; clicking any one will switch to the corresponding operation interface.
1548
1549 == **8 Modify device value** ==
1550
1551 **Modify device value**: modify the PLC internal register and coil value; modify the expansion device register value. As shown below:
1552
1553 (% style="text-align:center" %)
1554 [[image:image-20220628143453-3.jpeg]]
1555
1556 (% style="text-align:center" %)
1557 [[image:image-20220628143458-4.jpeg]]
1558
1559 **PLC internal devices:**
1560
1561 * **Devices:**
1562 ** "Devicess" are registers and coils (such as C0, M1, etc.) whose values need to be modified within the range of PLC.
1563 ** "Data type" includes Word (single word) , Bit (binary 0 or 1), double Word, float (single precision floating point number).
1564 ** "Value" is the specific value to be modified (corresponding to the number in the range of "Data Type"), such as -120.
1565 ** The data format can be decimal (single word: -32768 to 32767; double word:  -2147483648 to 2147483647) or hexadecimal (single word: 0 to FFFF; double word:  0 to FFFFFFFF).
1566 ** Click "Set" to write the set value within the correct range to the selected device.
1567 * **Execution result: **Record the successfully modified "device", "data type" and "set value" in the form of a list.
1568 * **Record list:**
1569 ** Click any one in the list, and click "Delete" to delete it.
1570 ** Click "Clear List" to clear the record list.
1571 ** Select any one in the record list and click "**Response to Input Field**" to reflect the items in "device" .
1572
1573 **PLC external expansion module:**
1574
1575 * "Module start" is the extension module number (such as module 0).
1576 * "Address" is the internal writable address of the expansion module, and the address type can be decimal or hexadecimal.
1577 * "Data type" includes Word (single word), Double Word, Float (single precision floating point number) .
1578 * "Value" is the specific value to be modified (corresponding to the number in the "data type" range), such as -120. The type can be decimal or hexadecimal.
1579 * The data can be decimal (single word: -32768 to 32767; double word: -2147483648 to 2147483647) or hexadecimal (single word: 0 to FFFF; double word: 0 to FFFFFFFF).
1580 * Click "Set" to write the set value within the correct range to the selected device.
1581
1582 **✎Note: **
1583
1584 1. Modification of the device value must be executed in the case of communication with the PLC.
1585 1. The device must be within the available range of the corresponding PLC model.
1586 1. The input value must be within the allowable range.
1587 1*. Decimal: single word (-32768 to 32767), double word (-2147483648 to 2147483647)
1588 1*. Hexadecimal: single word (0 to FFFF); double word (0to FFFFFFFF)
1589 1*. Floating: ±1.175495E-38 to 3.402823E+38
1590
1591 = **9 Print ladder diagram** =
1592
1593 The print function is divided into: print, print preview, and print settings.
1594
1595 **Preconditions for printing**
1596
1597 1. Open the project file (not the project file generated by the "Generate Download File" function).
1598 1. The program has all been compiled.
1599 1. The program is in edit mode.
1600
1601 Only when the above three conditions are met, the print button can be clicked.
1602
1603 (% style="text-align:center" %)
1604 [[image:image-20220628145819-5.jpeg]]
1605
1606 == **Printing preview** ==
1607
1608 Before printing, you could preview the print on the screen. Click the "File" → "Print" → "Print Preview" to open the print preview window as shown in the figure below:
1609
1610 (% style="text-align:center" %)
1611 [[image:image-20220628145842-6.jpeg]]
1612
1613 **Print preview interface**
1614
1615 (% style="text-align:center" %)
1616 [[image:image-20220628145927-7.jpeg]]
1617
1618 == **Print** ==
1619
1620 When you need to print, please click the print button, and a standard print dialog box will pop up. You could set the print options here. After setting, you could click "OK" to output the current program to the printer.
1621
1622 (% style="text-align:center" %)
1623 [[image:image-20220628150306-8.jpeg]]
1624
1625 == **Printer settings** ==
1626
1627 Set print information. As shown below:
1628
1629 (% style="text-align:center" %)
1630 [[image:image-20220628150319-9.jpeg]]
1631
1632 = **10 Status bar** =
1633
1634 Indication: language, uppercase and lowercase status, digital keyboard lock status, rewrite/insert status, communication port, project model, current program steps/total program steps and other status information.
1635
1636 (% style="text-align:center" %)
1637 [[image:image-20220628150551-10.jpeg]]
1638
1639 * **Language: **The language type displayed by the software. Highlighted means enabled.
1640 * **Case state:** English input state.
1641 * **Numeric keypad lock:** Whether the numeric keypad is available.
1642 * **Rewrite/insert state:** ladder diagram editing mode.
1643 * **Communication port:** communication COM port. Click it to pop up the communication setting window.
1644 * **Project Type:** Display the PLC model of the current project.
1645 * **Current program steps/total program steps:** Program editing page, program steps of the currently selected instruction/total program steps.
1646
1647 = **11 Device usage list** =
1648
1649 The device usage list mainly displays the specified type of device. You could check the usage, and the corresponding comment and alias of the device.
1650
1651 (% style="text-align:center" %)
1652 [[image:image-20220628152232-11.jpeg]]
1653
1654 **Instructions for using the list of devices:**
1655
1656 * Device selection drop-down box: select the drop-down box option, search for and display the usage of the corresponding type of Device (starting from serial number 0).
1657
1658 (% style="text-align:center" %)
1659 [[image:image-20220628152301-12.jpeg]]
1660
1661 * Start devices drop-down box: You could enter the full name or serial number of the start devices, press the Enter key or press the "search" button to search and display the usage of this type of devices (starting from the initial serial number). Record the search record in the drop-down box. After selecting the record, you could perform the search again.
1662
1663 (% style="text-align:center" %)
1664 [[image:image-20220628152611-13.jpeg]]
1665
1666 * Search button: Perform a search operation. When the starting device is empty, it will prompt to input a device.
1667
1668 (% style="text-align:center" %)
1669 [[image:image-20220628152633-14.jpeg]]
1670
1671 * Search range: Specify the search range of the device.
1672 ** Current program page: Search only for the currently active program page.
1673 ** Current program type: Only for all program pages of the same type in the currently activated program page.
1674 ** Whole project: for all program pages of the current project. (The program page types are divided into: scan, event, subroutine, interrupt)
1675
1676 (% style="text-align:center" %)
1677 [[image:image-20220628152800-15.jpeg]]
1678
1679 * Expand and close the sub-items of the device usage list.
1680
1681 (% style="text-align:center" %)
1682 [[image:image-20220628153639-16.jpeg]]
1683
1684 * The sub-items of the devices usage list includes instruction, step number, type and other information of the devices in the program. Double-click the content of the sub-item to locate the corresponding position in the program.
1685
1686 (% style="text-align:center" %)
1687 [[image:image-20220628153730-17.jpeg]]
1688
1689 * Device comment and alias column: (the background color is white) displays the comment or alias of the device.
1690
1691 (% style="text-align:center" %)
1692 [[image:image-20220628153741-18.jpeg]]
1693
1694 **Display options:**
1695
1696 * All devicess: After selecting, search all devicess of this type.
1697
1698 (% style="text-align:center" %)
1699 [[image:image-20220628154043-19.jpeg]]
1700
1701 * Used devices: After selecting, search for the used devices of this type according to the contact and coil options.
1702 ** Neither the contact nor the coil is selected, and all the devicess of this type that have been used in the program are displayed.
1703 ** Select the contact (coil) to display the type of devices as the contact (coil) in the program.
1704 ** Select both contacts and coils, and display the type of devices that are used as contacts and coils in the program.
1705
1706 (% style="text-align:center" %)
1707 [[image:image-20220628154051-20.jpeg]]
1708
1709 * Unused devices: After selecting, display all the devicess of this type that are not used in the program.
1710
1711 (% style="text-align:center" %)
1712 [[image:image-20220628154101-21.jpeg]]
1713
1714 = **12 Shortcut keys list** =
1715
1716 == **Universal shortcut keys** ==
1717
1718 The universal shortcut keys are as follows:
1719
1720 (% class="table-bordered" %)
1721 |(% style="width:129px" %)**hot key**|(% style="width:306px" %)**Corresponding menu (function name)**|(% style="width:641px" %)**summary**
1722 |(% style="width:129px" %)Ctrl + N|(% style="width:306px" %)New Project|(% style="width:641px" %)New Project
1723 |(% style="width:129px" %)Ctrl + O|(% style="width:306px" %)Open the project|(% style="width:641px" %)Open an existing project
1724 |(% style="width:129px" %)Ctrl + S|(% style="width:306px" %)Save the project|(% style="width:641px" %)Save the project
1725 |(% style="width:129px" %)Ctrl + X|(% style="width:306px" %)Cut|(% style="width:641px" %)Cut selected data and range
1726 |(% style="width:129px" %)Ctrl + C|(% style="width:306px" %)Copy|(% style="width:641px" %)Copy selected data and range
1727 |(% style="width:129px" %)Ctrl + V|(% style="width:306px" %)Paste|(% style="width:641px" %)Cut/paste the copied data at the cursor position
1728 |(% style="width:129px" %)Ctrl + Z|(% style="width:306px" %)Revoke|(% style="width:641px" %)Revoke the previous operation
1729 |(% style="width:129px" %)Ctrl + Y|(% style="width:306px" %)Restore|(% style="width:641px" %)Resume the operation cancelled by [Undo]
1730 |(% style="width:129px" %)Ctrl + F|(% style="width:306px" %)Search device|(% style="width:641px" %)Search device
1731 |(% style="width:129px" %)Ctrl + F1|(% style="width:306px" %)Display/hide menu toolbar|(% style="width:641px" %)Display/hide menu toolbar
1732 |(% style="width:129px" %)F3|(% style="width:306px" %)Start Monitoring|(% style="width:641px" %)Currently, start to monitor the window that is the target of the operation
1733 |(% style="width:129px" %)Ctrl + F3|(% style="width:306px" %)Monitoring stop|(% style="width:641px" %)Currently, stop monitoring the window that is the target of operation
1734 |(% style="width:129px" %)F4|(% style="width:306px" %)Compile|(% style="width:641px" %)Compile (switch) the program page currently being edited
1735 |(% style="width:129px" %)Ctrl+F4|(% style="width:306px" %)Compile all|(% style="width:641px" %)Compile (switch) all program pages in the current project
1736 |(% style="width:129px" %)Alt+F4|(% style="width:306px" %)Exit the software|(% style="width:641px" %)Exit the software
1737
1738 == **Shortcut keys for ladder editor** ==
1739
1740 The shortcut keys that can be used in the ladder diagram editor are as follows:
1741
1742 (% class="table-bordered" %)
1743 |(% style="width:150px" %)**Shortcut key**|(% style="width:353px" %)**Corresponding menu (function name)**|**Summary**
1744 |(% style="width:150px" %)F5|(% style="width:353px" %)Normally open contact|Write normally open contact to the cursor position
1745 |(% style="width:150px" %)Shift + F5|(% style="width:353px" %)Normally open contact OR|Write normally open contact OR to the cursor position
1746 |(% style="width:150px" %)F6|(% style="width:353px" %)Normally closed contact|Write normally closed contact to the cursor position
1747 |(% style="width:150px" %)Shift + F6|(% style="width:353px" %)Normally closed contact OR|Write normally closed contact OR to the cursor position
1748 |(% style="width:150px" %)F7|(% style="width:353px" %)Coil|Write coil to the cursor position
1749 |(% style="width:150px" %)F8|(% style="width:353px" %)Application instructions|Write application instructions to the cursor position
1750 |(% style="width:150px" %)F9|(% style="width:353px" %)Horizontal line input|Write horizontal line to cursor position
1751 |(% style="width:150px" %)F11|(% style="width:353px" %)Vertical line input|Write the vertical line to the cursor position
1752 |(% style="width:150px" %)Ctrl + F9|(% style="width:353px" %)Delete horizontal line|Delete the horizontal line at the cursor position
1753 |(% style="width:150px" %)Ctrl + F11|(% style="width:353px" %)Delete vertical line|Delete the vertical line at the cursor position
1754 |(% style="width:150px" %)Shift + F7|(% style="width:353px" %)Rising edge pulse|Write the rising edge pulse to the cursor position
1755 |(% style="width:150px" %)Shift + F8|(% style="width:353px" %)Falling edge pulse|Write the falling edge pulse to the cursor position
1756 |(% style="width:150px" %)Ctrl + Alt + F7|(% style="width:353px" %)Parallel rising edge pulse|Write the parallel rising edge pulse to the cursor position
1757 |(% style="width:150px" %)Ctrl + Alt + F8|(% style="width:353px" %)Parallel falling edge pulse|Write the parallel falling edge pulse to the cursor position
1758 |(% style="width:150px" %)Ctrl + Alt + F11|(% style="width:353px" %)Invert the result of the operation|Write the result of the calculation to the cursor position
1759 |(% style="width:150px" %)Ctrl + Shift + Insert|(% style="width:353px" %)Insert statement between lines|Insert the declaration line at the cursor position
1760 |(% style="width:150px" %)Shift + Insert|(% style="width:353px" %)Insert program row|Insert the  row at the cursor position
1761 |(% style="width:150px" %)Shift + Delete|(% style="width:353px" %)Delete row|Delete the row at the cursor position
1762 |(% style="width:150px" %)Ctrl + Insert|(% style="width:353px" %)Insert column|Insert the column at cursor position
1763 |(% style="width:150px" %)Ctrl + Delete|(% style="width:353px" %)Delete column|Delete the column at the cursor position
1764 |(% style="width:150px" %)Ctrl + →|(% style="width:353px" %)Enter/delete horizontal line in the right direction|Enter/delete horizontal line from the cursor position to the right
1765 |(% style="width:150px" %)Ctrl + ←|(% style="width:353px" %)Horizontal line input/delete in the left direction|Enter/delete horizontal line from the cursor position to the left
1766 |(% style="width:150px" %)Ctrl + ↓|(% style="width:353px" %)Enter/delete the vertical line in the downward direction|Enter/delete the vertical line from the cursor position down
1767 |(% style="width:150px" %)Ctrl + ↑|(% style="width:353px" %)Upward vertical line input/delete|Enter/delete the vertical line up from the cursor position
1768 |(% style="width:150px" %)Ctrl + /|(% style="width:353px" %)Normally open/normally closed contact switching|Switch between normally open contact and normally closed contact
1769 |(% style="width:150px" %)Ctrl + G|(% style="width:353px" %)Jump|Display jump to the instruction position corresponding to the specified number of steps
1770 |(% style="width:150px" %)Ctrl + F5|(% style="width:353px" %)Comment display|Display device comments and label comments
1771 |(% style="width:150px" %)Ctrl + F7|(% style="width:353px" %)Statement display|Display statement