Function differences between LX6 series PLCs?

Version 11.1 by Jiahao Lai on 2026/01/17 10:25

LX6V/S series

ModelDigital tube displayRecommended EtherCAT axisHigh speed InputHigh speed OutputEtherNet/IPOPC UAModbus RTU/TCPMCCNCROBOTICWebvisu
LX6S-0808MT-DANone8

8*150K Hz single phase

4*150K Hz AB phase

4*200K HzSupportSupportSupportSupportNoneNoneNone
LX6S-0808MT-DB16
LX6V-0808MT-DBSupport16
LX6V-0808MT-DC32
LX6V-0808MT-DD64
LX6V-0808MT-DE128

AC60 series

Information

The following function description is only for versions after January 2025

ModelDigital tube displayRecommended EtherCAT axisHigh speed InputHigh speed OutputEtherNet/IPOPC UAModbus RTU/TCPMCCNCROBOTICWebvisu
AC60-0808MT-D0NoneNone

4*200K Hz single phase

4*150K Hz AB phase

4*200K HzSupportNoneSupportSupportNoneNoneNone
AC60-0808MT-DANone8NoneNoneNoneNone
AC60-0808MT-DBSupport16NoneSupportSupportNone
AC60-0808MT-DC32NoneSupportSupportSupport
AC60-0808MT-DD64SupportSupportSupportSupport