Summary

Details

Page properties
Content
... ... @@ -96,7 +96,7 @@
96 96  Power-on
97 97  
98 98  again
99 -)))|(% style="width:69px" %)0~~1|(((
99 +)))|(% style="width:69px" %)0-1|(((
100 100  Forward direction:viewed from the motor shaft.
101 101  
102 102  0: CW direction as the forward direction
... ... @@ -126,7 +126,7 @@
126 126  
127 127  **Time**
128 128  )))|=(% style="width: 83px;" %)**Range**|=(% style="width: 418px;" %)**Function**|=**Unit**|=**Default**
129 -|(% style="width:81px" %)P0-9|(% style="width:220px" %)Braking resistance|(% style="width:81px" %)At stop|(% style="width:83px" %)Immediate|(% style="width:83px" %)0~~3|(% style="width:418px" %)(((
129 +|(% style="width:81px" %)P0-9|(% style="width:220px" %)Braking resistance|(% style="width:81px" %)At stop|(% style="width:83px" %)Immediate|(% style="width:83px" %)0-3|(% style="width:418px" %)(((
130 130  0- Use built-in braking resistor.
131 131  
132 132  1- Use external braking resistor and natural cooling.
... ... @@ -135,18 +135,18 @@
135 135  
136 136  3- No braking resistors are used, all rely on capacitor absorption.
137 137  )))|-|0
138 -|(% style="width:81px" %)P0-10|(% style="width:220px" %)External braking resistance|(% style="width:81px" %)At stop|(% style="width:83px" %)Immediate|(% style="width:83px" %)0~~65535|(% style="width:418px" %)set the resistance value of the external braking resistor.|Ω|50
139 -|(% style="width:81px" %)P0-11|(% style="width:220px" %)External braking resistor power|(% style="width:81px" %)At stop|(% style="width:83px" %)Immediate|(% style="width:83px" %)0~~65535|(% style="width:418px" %)Used to set the power of external braking resistor.|W|100
138 +|(% style="width:81px" %)P0-10|(% style="width:220px" %)External braking resistance|(% style="width:81px" %)At stop|(% style="width:83px" %)Immediate|(% style="width:83px" %)0-65535|(% style="width:418px" %)set the resistance value of the external braking resistor.|Ω|50
139 +|(% style="width:81px" %)P0-11|(% style="width:220px" %)External braking resistor power|(% style="width:81px" %)At stop|(% style="width:83px" %)Immediate|(% style="width:83px" %)0-65535|(% style="width:418px" %)Used to set the power of external braking resistor.|W|100
140 140  
141 141  **Braking resistor selection process**
142 142  
143 143  (% style="text-align:center" %)
144 -[[image:Braking resistor.png||class="img-thumbnail" height="1197" width="800"]]
144 +[[image:Braking resistor.png||height="1197" width="800" class="img-thumbnail"]]
145 145  
146 146  
147 147  **VD1 750W drive brake resistance calculation formula**
148 148  
149 -750W motor inertia : 1.82*10^^-4^^ kg m^^2^^
149 +750W motor inertia: 1.82*10^^-4^^ kg m^^2^^
150 150  
151 151  Total load inertia J,,L,, = load inertia ratio * 1.82*10^^-4^^
152 152