05 Panel

Last modified by Mora Zhou on 2024/07/15 15:05

Panel composition

The panel composition of the VD2 series servo drive is shown in Figure 5-1 (take VD2A servo drive as an example).

image-20220608150147-1.png

Figure 5-1 The exterior of VD2A servo drive panel

The panel of the VD2 series servo drive consists of a display (5-digit LED nixie tube) and keys, which can be used for the execution of various displays, parameter settings and other functions of the servo drive. Taking parameter setting as an example, the general functions of the keys are shown in Table 5-1.

IconNameFunction
image-20220611124230-1.pngMode
  1. Mode switching
  2. Return to the previous menu
image-20220611124236-2.pngIncreaseIncrease the value of the LED flashing bit
image-20220611124240-3.pngDecreaseDecrease the value of the LED flashing bit
image-20220611124245-4.pngSHIFT key
  1. Change the LED flashing bit
  2. View the high-bit value of data with a length greater than 4-bit
image-20220611124250-5.pngEnter (OK)
  1. Enter the next menu
  2. Execute commands such as storing parameter setting values

Table 5-1 key functions

Panel display

When servo drive is in operation, the panel could be used for status display, parameter display, fault display and monitoring display of the servo.

  • Status display: Display the current operating status of servo drive.
  • Parameter display: Display the function codes corresponding to different functions and the set values of the function codes.
  • Fault display: Display the fault code of servo drive.
  • Monitor display: Display the current operating parameter values of servo drive.

Display switching

image-20220608151534-2.png

Figure 5-2 Switch between display types on the panel

Illustrate:

  1. The power is turned on, and the panel display of the servo drive enters “Status Display Mode”.
  2. After an operation failure occurs, the panel immediately switches to the bit failure display mode. At this time, all the nixie tubes flash synchronously. Press the "mode" key to switch to the parameter display mode.
  3. Press the "Mode" key to switch between different display modes, and the switching conditions are shown in Figure 5-2.

Status display

DisplayDisplay occasionMeaning
image-20220611124534-6.jpegServo drive is powered on within 1 secondServo drive is in initialization status
image-20220611124804-7.jpegVery short time after displaying "88888"Initialization is complete
image-20220611124808-8.jpeg1 second after servo drive is powered on, servo is readyThe servo is ready, waiting for the enable signal given by servo drive
image-20220611124813-9.jpegServo enable signal is validThe servo drive is in an operational status, waiting for the instructions from host computer
image-20220706140058-1.jpeg

 

Servo drive is in jog operationJog operation settings

Table 5-2 Status display example

Parameter display

VD2 series servo drives are divided into 13 groups of function codes according to different parameter functions, which could quickly locate the position of function codes according to the function code groups. For the specific parameters refer to “9 Parameters".

Parameter group display

The parameter display is the display of different function codes. The format of the function code is “PXX.YY”. “PXX” indicates the group number of function code, and “YY” indicates the number within the function code group.

DisplayNameContent
PXX.YYFunction code group numberNumber in function code group

For example: The function code P00.01 is displayed as follows.

DisplayNameContent
image-20220706143908-1.jpegFunction code P00.01
  • 00: Function code group number
  • 01: Number in the function code group

Display of different length data

Display Data with four bits and below

  • Using single page display, if it is a signed number, the highest bit of the data is "-".
  • For example: The monitoring volume U0-02 is displayed as follows.
DisplayNameContent
image-20220706144048-2.jpegMonitoring volume U0-02Servo motor speed

Display Data more than five bits

  • Display in pages from low to high bits, and each 4 bits is a page. Display method: current page + current value.as shown in Figure 5-3 and Figure 5-4, switch current page by pressing the "Shift" key.
  • For example: 2147483646 is displayed as follows:
image-20220611155447-1.png

Figure 5-3 2147483646 display operation

For example: -2147483647 is displayed as follows:

Wecon VD2 SA Series Servo Drives Manual (Full V1.1)_html_c63bc504c89e53a8.png

Figure 5-4 -2147483647 display operation

Decimal point display

The "." of the one-digit indicates the decimal point, and it does not flash. The example is as follows.

DisplayNameContent
image-20220706144358-4.jpegDecimal point302.4

Parameter setting display

DisplayNameDisplay occasionMeaning
Wecon VD2 SA Series Servo Drives Manual (Full V1.1)_html_71833477b416faaf.gif

Done

Parameter setting completed

Parameter reset factoryThe servo drive is in the process of parameter factory reset
Wecon VD2 SA Series Servo Drives Manual (Full V1.1)_html_66661c97974ab485.gif

P.Init

Parameter reset factory

Parameter reset factoryThe servo drive is in the process of parameter factory reset
Wecon VD2 SA Series Servo Drives Manual (Full V1.1)_html_fe94062b992abf5a.gif

Error

Parameter error

Parameter setting exceeds the limit (or not allowed to exceed the limit)Prompt that the parameter setting exceeds the limit

Table 5-3 Parameter setting display

Fault display

The panel can display current or historical fault and warning codes. For analysis and troubleshooting of faults and warnings, please refer to "10 Malfuctions" .

When a single fault or warning occurs, the panel immediately displays the current fault or warning code;

when multiple faults or warnings occur, the highest fault code is displayed. When a fault occurs, when switching from the auxiliary function to the parameter display function, the corresponding fault or warning code will be displayed. You can view the current fault and warning codes and the past five fault and warning codes through the monitor display on the panel.

DisplayNameContent
Wecon VD2 SA Series Servo Drives Manual (Full V1.1)_html_b9eb712b45c52172.gifParameter modification that needs to be powered on againModified the parameters that need to be re-powered to take effect

Table 5-4 Warning display example

DisplayNameContent
Wecon VD2 SA Series Servo Drives Manual (Full V1.1)_html_b851b96afa7ab426.gifMotor overload protectionMotor overload protection

Table 5-5 Fault display example

Monitor display

After the servo drive is powered on or the servo enable is ON, you can press the "Mode" key to enter the monitor display mode.

Display

Monitoring volume

NameUnitMeaning

image-20220706144943-5.jpeg

image-20220706144956-6.jpeg

U0-02Servo motor speedrpmIndicates the actual operating speed of servo motor, expressed in decimal.
Wecon VD2 SA Series Servo Drives Manual (Full V1.1)_html_cfc3d1a6717e72f0.gifU0-31Bus voltageVIndicates the voltage value between P+ and - of the drive, the DC bus voltage
Wecon VD2 SA Series Servo Drives Manual (Full V1.1)_html_80f9014fcbb17741.gifU0-17Input signal status-Indicates the level status corresponding to the 8 DI terminals. The upper half of the LED light indicates high level, and the lower half light indicates low level. (The VD2F model has only 4 DI ports)
image-20220706145041-7.jpegU0-19Output signal status-Indicates the level status corresponding to the 4 DO terminals. The upper half of the LED light indicates high level, and the lower half light indicates low level.

Table 5-6 Monitoring volume display example

Panel operation

Parameter setting

Use the servo drive panel to set the parameters. For details about the parameters, please refer to " 9 Parameters". Take P00.01 as an example to set the parameters to change the control mode of the servo drive from position control mode to speed control mode. The setting steps are shown in Figure 5-5.

Illustrate:

  • The power supply is in Rdy state after power on.
  • Press "Mode" key to enter the function code parameter interface.
  • Press "Confirm" key to enter the function code value modification interface after completing the function code selection.
  • Press the "Up" and "Down" keys to modify the parameter value.
  • Press the "Confirm" key twice to complete the value modification.
image-20220608162758-1.png

Figure 5-5 Schematic diagram of parameter setting steps.

Jog operation

In order to test run the servo motor and the servo drive, you can use the jog running function. The operation steps are shown in Figure 5-6.

Illustrate:

  • Adjust the function code to P10.01 after power on.
  • Press the "Enter" key to enter the next menu to set the JOG jog speed.
  • After the “JOG jog speed” setting is completed, press the "Enter" key, the panel displays “JOG” in a flashing state, press the "Enter" key again to enter the JOG mode.
  • Long press the "Up" key and "Down" key to realize the forward and reverse rotation of the motor.
  • Press the "Mode" key to exit the JOG mode.
  • Reason for displaying Error: Please refer to “10 Malfunctions" according to the corresponding fault codes.
image-20220706145151-8.jpeg

Figure 5-6 Jog operation setting steps

Factory reset

The factory settings can be restored through the servo drive panel. The specific operation steps are shown in Figure 5-7.

Illustrate:

  • After power on, modify the function code to P10.02.
  • Press the "Enter" key to enter the next menu to set the parameters.
  • Press the "Confirm" button after the parameter setting is finished, and the setting value will flash.
  • Press "Confirm" again, the panel digital tube will light up gradually from left to right until 8.8.8.8.8 is displayed.
  • Finally it displays “Done”, the servo drive will be re-powered and the operation of factory reset is finished.
image-20220706150348-9.jpeg

Figure 5-7 Steps for restoring factory settings