... ... @@ -174,18 +174,20 @@
174 174  After the servo drive is powered on or the servo enable is ON, you can press the "Mode" key to enter the monitor display mode.
175 175  
176 176  (% class="table-bordered" %)
177 -|(% style="text-align:center; vertical-align:middle" %)**Display**|(% style="text-align:center; vertical-align:middle; width:202px" %)(((
177 +|(% style="text-align:center; vertical-align:middle; width:320px" %)**Display**|(% style="text-align:center; vertical-align:middle; width:107px" %)(((
178 178  **Monitoring volume**
179 -)))|(% style="text-align:center; vertical-align:middle; width:179px" %)**Name**|(% style="text-align:center; vertical-align:middle; width:159px" %)**Unit**|(% style="text-align:center; vertical-align:middle; width:753px" %)**Meaning**
180 -|(% style="text-align:center; vertical-align:middle" %)(((
181 -[[image:Wecon VD2 SA Series Servo Drives Manual (Full V1.1)_html_fed555ae469c643d.gif]]
179 +)))|(% style="text-align:center; vertical-align:middle; width:168px" %)**Name**|(% style="text-align:center; vertical-align:middle; width:77px" %)**Unit**|(% style="text-align:center; vertical-align:middle; width:438px" %)**Meaning**
180 +|(% style="text-align:center; vertical-align:middle; width:320px" %)(((
181 +
182 182  
183 -[[image:Wecon VD2 SA Series Servo Drives Manual (Full V1.1)_html_acb651c29bc239bf.gif]]
184 -)))|(% style="text-align:center; vertical-align:middle; width:202px" %)U0-02|(% style="text-align:center; vertical-align:middle; width:179px" %)Servo motor speed|(% style="text-align:center; vertical-align:middle; width:159px" %)rpm|(% style="width:753px" %)Indicates the actual operating speed of servo motor, expressed in decimal.
185 -|(% style="text-align:center; vertical-align:middle" %)[[image:Wecon VD2 SA Series Servo Drives Manual (Full V1.1)_html_cfc3d1a6717e72f0.gif]]|(% style="text-align:center; vertical-align:middle; width:202px" %)U0-31|(% style="text-align:center; vertical-align:middle; width:179px" %)Bus voltage|(% style="text-align:center; vertical-align:middle; width:159px" %)V|(% style="width:753px" %)Indicates the voltage value between P+ and - of the drive, the DC bus voltage
186 -|(% style="text-align:center; vertical-align:middle" %)[[image:Wecon VD2 SA Series Servo Drives Manual (Full V1.1)_html_80f9014fcbb17741.gif]]|(% style="text-align:center; vertical-align:middle; width:202px" %)U0-17|(% style="text-align:center; vertical-align:middle; width:179px" %)Input signal status|(% style="text-align:center; vertical-align:middle; width:159px" %)-|(% style="width:753px" %)Indicates the level status corresponding to the 8 DI terminals. The upper half of the LED light indicates high level, and the lower half light indicates low level. **(The VD2F model has only 4 DI ports)**
187 -|(% style="text-align:center; vertical-align:middle" %)[[image:Wecon VD2 SA Series Servo Drives Manual (Full V1.1)_html_d032ad3556119999.gif]]|(% style="text-align:center; vertical-align:middle; width:202px" %)U0-19|(% style="text-align:center; vertical-align:middle; width:179px" %)Output signal status|(% style="text-align:center; vertical-align:middle; width:159px" %)-|(% style="width:753px" %)Indicates the level status corresponding to the 4 DO terminals. The upper half of the LED light indicates high level, and the lower half light indicates low level.
183 +[[image:image-20220706144943-5.jpeg]]
188 188  
185 +[[image:image-20220706144956-6.jpeg]]
186 +)))|(% style="text-align:center; vertical-align:middle; width:107px" %)U0-02|(% style="text-align:center; vertical-align:middle; width:168px" %)Servo motor speed|(% style="text-align:center; vertical-align:middle; width:77px" %)rpm|(% style="width:438px" %)Indicates the actual operating speed of servo motor, expressed in decimal.
187 +|(% style="text-align:center; vertical-align:middle; width:320px" %)[[image:Wecon VD2 SA Series Servo Drives Manual (Full V1.1)_html_cfc3d1a6717e72f0.gif]]|(% style="text-align:center; vertical-align:middle; width:107px" %)U0-31|(% style="text-align:center; vertical-align:middle; width:168px" %)Bus voltage|(% style="text-align:center; vertical-align:middle; width:77px" %)V|(% style="width:438px" %)Indicates the voltage value between P+ and - of the drive, the DC bus voltage
188 +|(% style="text-align:center; vertical-align:middle; width:320px" %)[[image:Wecon VD2 SA Series Servo Drives Manual (Full V1.1)_html_80f9014fcbb17741.gif]]|(% style="text-align:center; vertical-align:middle; width:107px" %)U0-17|(% style="text-align:center; vertical-align:middle; width:168px" %)Input signal status|(% style="text-align:center; vertical-align:middle; width:77px" %)-|(% style="width:438px" %)Indicates the level status corresponding to the 8 DI terminals. The upper half of the LED light indicates high level, and the lower half light indicates low level. **(The VD2F model has only 4 DI ports)**
189 +|(% style="text-align:center; vertical-align:middle; width:320px" %)[[image:image-20220706145041-7.jpeg]]|(% style="text-align:center; vertical-align:middle; width:107px" %)U0-19|(% style="text-align:center; vertical-align:middle; width:168px" %)Output signal status|(% style="text-align:center; vertical-align:middle; width:77px" %)-|(% style="width:438px" %)Indicates the level status corresponding to the 4 DO terminals. The upper half of the LED light indicates high level, and the lower half light indicates low level.
190 +
189 189  Table 5-6 Monitoring volume display example
190 190  
191 191  = **Panel operation** =
... ... @@ -194,6 +194,14 @@
194 194  
195 195  Use the servo drive panel to set the parameters. For details about the parameters, please refer to __[[" 9 Parameters">>https://docs.we-con.com.cn/bin/view/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/09%20Parameters/]]__. Take P00.01 as an example to set the parameters to change the control mode of the servo drive from position control mode to speed control mode. The setting steps are shown in __[[Figure 5-5>>https://docs.we-con.com.cn/bin/download/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/05%20Panel/WebHome/image-20220608162758-1.png?rev=1.1]]__.
196 196  
199 +**Illustrate:**
200 +
201 +* The power supply is in Rdy state after power on.
202 +* Press "Mode" key to enter the function code parameter interface.
203 +* Press "Confirm" key to enter the function code value modification interface after completing the function code selection.
204 +* Press the "Up" and "Down" keys to modify the parameter value.
205 +* Press the "Confirm" key twice to complete the value modification.
206 +
197 197  (% style="text-align:center" %)
198 198  [[image:image-20220608162758-1.png]]
199 199  
... ... @@ -205,16 +205,15 @@
205 205  
206 206  **Illustrate:**
207 207  
208 -1. Adjust the function code to P10.01 after power on.
209 -1. Press the "Enter" key to enter the next menu to set the JOG jog speed.
210 -1. After the “JOG jog speed” setting is completed, press the "Enter" key, the panel displays “JOG” in a flashing state, press the "Enter" key again to enter the JOG mode.
211 -1. Long press the "Up" key and "Down" key to realize the forward and reverse rotation of the motor.
212 -1. Press the "Mode" key to exit the JOG mode.
218 +* Adjust the function code to P10.01 after power on.
219 +* Press the "Enter" key to enter the next menu to set the JOG jog speed.
220 +* After the “JOG jog speed” setting is completed, press the "Enter" key, the panel displays “JOG” in a flashing state, press the "Enter" key again to enter the JOG mode.
221 +* Long press the "Up" key and "Down" key to realize the forward and reverse rotation of the motor.
222 +* Press the "Mode" key to exit the JOG mode.
223 +* Reason for displaying Error: Please refer to[[ “10 Faults" >>path:#_Malfunctions]]according to the corresponding fault codes.
213 213  
214 -Reason for displaying Error: Please refer to __[[“10 Faults" >>https://docs.we-con.com.cn/bin/view/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/10%20Malfunctions/]]__according to the corresponding fault codes.
215 -
216 216  (% style="text-align:center" %)
217 -[[image:Wecon VD2 SA Series Servo Drives Manual (Full V1.1)_html_46d0c0afb3f9adbe.gif]]
226 +[[image:image-20220706145151-8.jpeg]]
218 218  
219 219  Figure 5-6 Jog operation setting steps
220 220  
... ... @@ -224,15 +224,13 @@
224 224  
225 225  **Illustrate:**
226 226  
227 -1. After power on, modify the function code to P10.02.
228 -1. Press the "Enter" key to enter the next menu to set the parameters.
229 -1. After the parameter setting is completed, press the "Enter" key to display “P.init”.
230 -1. Long press the "Enter" key for 3s, the panel digital tube will gradually light up from left to right until 88888 is displayed.
231 -1. When “done” is finally displayed, release the "Enter" key to indicate that the factory reset is complete.
236 +* After power on, modify the function code to P10.02.
237 +* Press the "Enter" key to enter the next menu to set the parameters.
238 +* Press the "Confirm" button after the parameter setting is finished, and the setting value will flash.
239 +* Press "Confirm" again, the panel digital tube will light up gradually from left to right until 8.8.8.8.8 is displayed.
240 +* Finally it displays “Done, the servo drive will be re-powered and the operation of factory reset is finished.
232 232  
233 -Error reason: When the parameter value of P10.02 exceeds the set range (0 to 1), “Error” will be displayed.
234 -
235 235  (% style="text-align:center" %)
236 -[[image:Wecon VD2 SA Series Servo Drives Manual (Full V1.1)_html_46722eeaa91a76f9.gif]]
243 +[[image:image-20220706150348-9.jpeg]]
237 237  
238 238  Figure 5-7 Steps for restoring factory settings
image-20220706144943-5.jpeg
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Stone
Size
... ... @@ -1,0 +1,1 @@
1 +8.2 KB
Content
image-20220706144956-6.jpeg
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Stone
Size
... ... @@ -1,0 +1,1 @@
1 +8.6 KB
Content
image-20220706145041-7.jpeg
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Stone
Size
... ... @@ -1,0 +1,1 @@