... ... @@ -291,6 +291,10 @@ 291 291 292 292 Table 7-7 Position loop gain parameters 293 293 294 +(% style="text-align:center" %) 295 +[[image:image-20220706153656-3.jpeg]] 296 + 297 + 294 294 **(4) Torque instruction filter time** 295 295 296 296 Selecting an appropriate torque filter time constant could suppress mechanical resonance. The larger the value of this parameter, the stronger the suppression ability. If the setting value is too large, it will decrease the current loop response frequency and cause needle movement. The related function codes are shown as below.