Changes for page 07 Adjustments
Last modified by Iris on 2025/07/24 11:03
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -137,20 +137,14 @@ 137 137 138 138 When debugging with the host computer debugging software, automatic rigidity level measurement can be carried out, which is used to select a set of appropriate rigidity grades as operating parameters. The operation steps are as follows: 139 139 140 -Step1 Confirm that the servo is in the ready state, the panel displays “rdy”, and the communication line is connected; 140 +* Step1 Confirm that the servo is in the ready state, the panel displays “rdy”, and the communication line is connected; 141 +* Step2 Open the host computer debugging software, enter the trial run interface, set the corresponding parameters, and click "Servo on"; 142 +* Step3 Click the "forward rotation" or "reverse rotation" button to confirm the travel range of the servo operation; 143 +* Step4 After the "start recognition" of inertia recognition lights up, click "start recognition" to perform inertia recognition, and the load inertia can be measured. 144 +* Step5 After the inertia recognition test is completed, click "Save Inertia Value"; 145 +* Step6 Click "Next" at the bottom right to go to the parameter adjustment interface, and click "Parameter measurement" to start parameter measurement. 146 +* Step7 After the parameter measurement is completed, the host computer debugging software will pop up a confirmation window for parameter writing and saving. 141 141 142 -Step2 Open the host computer debugging software, enter the trial run interface, set the corresponding parameters, and click "Servo on"; 143 - 144 -Step3 Click the "forward rotation" or "reverse rotation" button to confirm the travel range of the servo operation; 145 - 146 -Step4 After the "start recognition" of inertia recognition lights up, click "start recognition" to perform inertia recognition, and the load inertia can be measured. 147 - 148 -Step5 After the inertia recognition test is completed, click "Save Inertia Value"; 149 - 150 -Step6 Click "Next" at the bottom right to go to the parameter adjustment interface, and click "Parameter measurement" to start parameter measurement. 151 - 152 -Step7 After the parameter measurement is completed, the host computer debugging software will pop up a confirmation window for parameter writing and saving. 153 - 154 154 (% class="table-bordered" %) 155 155 |(% style="text-align:center; vertical-align:middle" %)[[image:image-20220611152634-2.png]] 156 156 |(((