Changes for page 07 Adjustments
Last modified by Iris on 2025/07/24 11:03
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -426,13 +426,13 @@ 426 426 427 427 Gain switching function: 428 428 429 -● 429 +●Switch to a lower gain in the motor stationary (servo enabled)state to suppress vibration; 430 430 431 -● 431 +●Switch to a higher gain in the motor stationary state to shorten the positioning time; 432 432 433 -● 433 +●Switch to a higher gain in the motor running state to get better command tracking performance; 434 434 435 -● 435 +●Switch different gain settings by external signals depending on the load connected. 436 436 437 437 (1) Gain switching parameter setting 438 438