Changes for page 07 Adjustments

Last modified by Iris on 2025/07/24 11:03

From version 38.13
edited by Karen
on 2023/05/15 17:19
Change comment: There is no comment for this version
To version 39.3
edited by Karen
on 2023/05/15 17:30
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -517,12 +517,12 @@
517 517  
518 518  |=(% rowspan="2" style="text-align: center; vertical-align: middle; width:120px" %)
519 519  **P02-07**|=(% style="width:150px" %)**Parameter name**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Setting method**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Effective time**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Default**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Set range**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Application category**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Unit**
520 -|(% style="text-align: center; width:150px" %)The second gain switching mode|(% style="text-align: center" %)Operation setting|(% style="text-align: center" %)Effective immediately|(% style="text-align: center" %)0|(% style="text-align: center" %)0 to 1|(% style="text-align: center" %)Gain control|
520 +|(% style="text-align:center; width:150px" %)The second gain switching mode|(% style="text-align:center" %)Operation setting|(% style="text-align:center" %)Effective immediately|(% style="text-align:center" %)0|(% style="text-align:center" %)0 to 1|(% style="text-align:center" %)Gain control|
521 521  |(% colspan="8" %)(((
522 522  Set the switching mode of the second gain.
523 523  
524 524  |=(% style="text-align: center; vertical-align: middle; width:120px" %) **Setting value**|=(% style="text-align: center; vertical-align: middle" %)**Function**
525 -|0|(((
525 +|=(% style="text-align: center; vertical-align: middle" %)0|(((
526 526  The first gain is used by default. Switching using DI function 10 (GAIN-SEL, gain switching):
527 527  
528 528  DI logic invalid: PI control;
... ... @@ -529,11 +529,11 @@
529 529  
530 530  DI logic valid: PI control.
531 531  )))
532 -|1|The first gain and the second gain are switched by the setting value of P02-08.
532 +|=(% style="text-align: center; vertical-align: middle" %)1|The first gain and the second gain are switched by the setting value of P02-08.
533 533  )))
534 534  
535 -|(% rowspan="2" %)
536 -**P02-08**|**Parameter name**|**Setting method**|**Effective time**|**Default**|**Set range**|**Application category**|**Unit**
535 +|(% rowspan="2" %)\\
536 +|=(% style="text-align: center; vertical-align: middle; width:120px" %)**P02-08**|**Parameter name**|**Setting method**|**Effective time**|**Default**|**Set range**|**Application category**|**Unit**
537 537  |Gain switching condition selection|Operation setting|Effective immediately|0|0 to 10|Gain control|
538 538  |(% colspan="8" %)(((
539 539  Set the conditions for gain switching.