Summary

Details

Page properties
Content
... ... @@ -539,7 +539,8 @@
539 539  
540 540  |=(% style="text-align: center; vertical-align: middle; width:120px" %)Setting value|=(% style="text-align: center; vertical-align: middle" %)Gain switching conditions|=(% style="text-align: center; vertical-align: middle" %)Details
541 541  |=(% style="text-align: center; vertical-align: middle" %)0|(% style="text-align:center; vertical-align:middle" %)The default is the first gain|Fixed use of the first gain
542 -|=(% style="text-align: center; vertical-align: middle" %)1|(% style="text-align:center; vertical-align:middle" %)Switch by DI port|(((
542 +|=(% style="text-align: center; vertical-align: middle" %)1|(% style="text-align:center; vertical-align:middle" %)Switch by DI port|
543 +(((
543 543  Use DI function 10 (GAIN-SEL, gain switching);
544 544  
545 545  DI logic is invalid: the first gain (P02-01~~P02-03);
... ... @@ -546,6 +546,7 @@
546 546  
547 547  DI logic is valid: the second gain (P02-04~~P02-06).
548 548  )))
550 +
549 549  |=(% style="text-align: center; vertical-align: middle" %)2|(% style="text-align:center; vertical-align:middle" %)Large torque command|(((
550 550  In the previous first gain, when the absolute value of torque command is greater than (grade + hysteresis), the second gain is switched;
551 551  
... ... @@ -594,7 +594,8 @@
594 594  |=(% style="text-align: center; vertical-align: middle" %)9|(% style="text-align:center; vertical-align:middle" %)Positioning complete|(((
595 595  In the previous first gain, if the positioning is not completed, the second gain is switched; In the previous second gain, if the positioning is not completed and the duration is greater than [P02-13], the first gain is returned.
596 596  )))
597 -|=(% style="text-align: center; vertical-align: middle" %)10|(% style="text-align:center; vertical-align:middle" %)Position command + actual speed|(((
599 +|=(% style="text-align: center; vertical-align: middle" %)10|(% style="text-align:center; vertical-align:middle" %)Position command + actual speed|
600 +(((
598 598  In the previous first gain, if the position command is not 0, the second gain is switched;
599 599  
600 600  In the previous second gain, if the position command is 0, the duration is greater than [P02-13] and the absolute value of actual speed is less than ( grade - hysteresis).