Changes for page 07 Adjustments
Last modified by Iris on 2025/07/24 11:03
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -550,36 +550,26 @@ 550 550 In the previous first gain, when the absolute value of torque command is greater than (grade + hysteresis), the second gain is switched; 551 551 552 552 In the previous second gain, when the absolute value of torque command is less than the value of (grade - hysteresis) and the duration is greater than [P02-13], the first gain is returned. 553 - 554 - 555 555 ))) 556 556 |=(% style="text-align: center; vertical-align: middle" %)3|(% style="text-align:center; vertical-align:middle" %)Large actual torque|((( 557 557 In the previous first gain, when the absolute value of actual torque is greater than ( grade + hysteresis ), the second gain is switched; 558 558 559 559 In the previous second gain, when the absolute value of actual torque is less than the value of (grade - hysteresis) and the duration is greater than [P02-13], the first gain is returned. 560 - 561 - 562 562 ))) 563 563 |=(% style="text-align: center; vertical-align: middle" %)4|(% style="text-align:center; vertical-align:middle" %)Large speed command|((( 564 564 In the previous first gain, when the absolute value of speed command is greater than (grade + hysteresis), the second gain is switched; 565 565 566 566 In the previous second gain, when the absolute value of speed command is less than the value of (grade - hysteresis) and the duration is greater than [P02-13], the first gain is returned. 567 - 568 - 569 569 ))) 570 570 |=(% style="text-align: center; vertical-align: middle" %)5|(% style="text-align:center; vertical-align:middle" %)Large actual speed|((( 571 571 In the previous first gain, when the absolute value of actual speed is greater than (grade + hysteresis), the second gain is switched; 572 572 573 573 In the previous second gain, when the absolute value of actual speed is less than the value of (grade - hysteresis) and the duration is greater than [P02-13], the first gain is returned. 574 - 575 - 576 576 ))) 577 577 |=(% style="text-align: center; vertical-align: middle" %)6|(% style="text-align:center; vertical-align:middle" %)Large rate of change in speed command|((( 578 578 In the previous first gain, when the absolute value of the rate of change in speed command is greater than (grade + hysteresis), the second gain is switched; 579 579 580 -In the previous second gain, switch to the first gain when the absolute value of the rate of change in speed command is less than the value of (grade - hysteresis) and the duration is greater than [P02-13], the first gain is returned. 581 - 582 - 572 +In the previous second gain, switch to the first gain when the absolute value of the rate of change in speed command is less than the value of (grade - hysteresis) and the duration is greater than [P02-13], the first gain is returned. 583 583 ))) 584 584 |=(% style="text-align: center; vertical-align: middle" %)7|(% style="text-align:center; vertical-align:middle" %)Large position deviation|((( 585 585 In the previous first gain, when the absolute value of position deviation is greater than (grade + hysteresis), the second gain is switched; ... ... @@ -598,12 +598,10 @@ 598 598 In the previous first gain, if the position command is not 0, the second gain is switched; 599 599 600 600 In the previous second gain, if the position command is 0, the duration is greater than [P02-13] and the absolute value of actual speed is less than ( grade - hysteresis). 601 - 602 -))) 603 603 ))) 592 +))) 604 604 605 -|(% rowspan="2" %) 606 -**P02-13**|**Parameter name**|**Setting method**|**Effective time**|**Default**|**Set range**|**Application category**|**Unit** 594 +|=(% rowspan="2" style="text-align:center; vertical-align:middle; width:120px" %) **P02-13**|=(% style="width:150px" %)Parameter name|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Setting method**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Effective time**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Default**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Set range**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Application category**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Unit** 607 607 |Delay Time for Gain Switching|Operation setting|Effective immediately|20|0 to 10000|Gain control|0.1ms 608 608 |(% colspan="8" %)((( 609 609 The duration of the switching condition required for the second gain to switch back to the first gain.