Changes for page 07 Adjustments
Last modified by Iris on 2025/07/24 11:03
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -463,42 +463,42 @@ 463 463 2 464 464 )))|(% style="text-align:center; vertical-align:middle; width:464px" %)((( 465 465 Large torque command 466 -)))|(% style=" width:946px" %)[[image:image-20230515140641-1.png]]466 +)))|(% style="text-align:center; vertical-align:middle" %)[[image:image-20230515140641-1.png||height="310" width="543"]] 467 467 |=(% style="text-align:center; vertical-align:middle" %)((( 468 468 3 469 -)))|(% style="text-align:center; vertical-align:middle; width:464px" %)Large actual torque|(% style="width:946px" %)[[image:image-20230515140641-2.png]] 469 +)))|(% style="text-align:center; vertical-align:middle; width:464px" %)((( 470 +Large actual torque 471 +)))|(% style="text-align:center; vertical-align:middle" %)[[image:image-20230515140641-2.png||height="252" width="550"]] 470 470 |=(% style="text-align:center; vertical-align:middle" %)((( 471 471 4 472 472 )))|(% style="text-align:center; vertical-align:middle; width:464px" %)((( 473 473 Large speed command 474 -)))|(% style=" width:946px" %)[[image:image-20230515140641-3.png]]476 +)))|(% style="text-align:center; vertical-align:middle" %)[[image:image-20230515140641-3.png||height="212" width="558"]] 475 475 |=(% style="text-align:center; vertical-align:middle" %)((( 476 476 5 477 477 )))|(% style="text-align:center; vertical-align:middle; width:464px" %)((( 478 478 Fast actual speed 479 -)))|(% style="width:946px" %)((( 480 -[[image:image-20230515140641-4.png]] 481 -))) 481 +)))|(% style="text-align:center; vertical-align:middle" %)[[image:image-20230515140641-4.png||height="223" width="561"]] 482 482 |=(% style="text-align:center; vertical-align:middle" %)((( 483 483 6 484 484 )))|(% style="text-align:center; vertical-align:middle; width:464px" %)((( 485 485 Speed command change rate is large 486 -)))|(% style=" width:946px" %)[[image:image-20230515140641-5.png]]487 -|=(% style="width:74px" %)((( 486 +)))|(% style="text-align:center; vertical-align:middle" %)[[image:image-20230515140641-5.png||height="327" width="570"]] 487 +|=(% style="text-align:center; vertical-align:middle;width:74px" %)((( 488 488 7 489 489 )))|(% style="text-align:center; vertical-align:middle; width:464px" %)((( 490 490 Large position deviation 491 -)))|(% style=" width:946px" %)[[image:image-20230515140641-6.png]]491 +)))|(% style="text-align:center; vertical-align:middle" %)[[image:image-20230515140641-6.png||height="305" width="574"]] 492 492 |=(% style="text-align:center; vertical-align:middle;" %)((( 493 493 8 494 494 )))|(% style="text-align:center; vertical-align:middle; width:464px" %)((( 495 495 Position command 496 -)))|(% style=" width:946px" %)[[image:image-20230515140641-7.png]]496 +)))|(% style="text-align:center; vertical-align:middle" %)[[image:image-20230515140641-7.png||height="280" width="570"]] 497 497 |=(% style="text-align:center; vertical-align:middle; width:74px" %)((( 498 498 9 499 499 )))|(% style="text-align:center; vertical-align:middle; width:464px" %)((( 500 500 Positioning completed 501 -)))|(% style=" width:946px" %)[[image:image-20230515140641-8.png]]501 +)))|(% style="text-align:center; vertical-align:middle" %)[[image:image-20230515140641-8.png||height="302" width="553"]] 502 502 |=(% style="text-align:center; vertical-align:middle" %)((( 503 503 10 504 504 )))|(% style="text-align:center; vertical-align:middle; width:464px" %)((( ... ... @@ -550,36 +550,26 @@ 550 550 In the previous first gain, when the absolute value of torque command is greater than (grade + hysteresis), the second gain is switched; 551 551 552 552 In the previous second gain, when the absolute value of torque command is less than the value of (grade - hysteresis) and the duration is greater than [P02-13], the first gain is returned. 553 - 554 - 555 555 ))) 556 556 |=(% style="text-align: center; vertical-align: middle" %)3|(% style="text-align:center; vertical-align:middle" %)Large actual torque|((( 557 557 In the previous first gain, when the absolute value of actual torque is greater than ( grade + hysteresis ), the second gain is switched; 558 558 559 559 In the previous second gain, when the absolute value of actual torque is less than the value of (grade - hysteresis) and the duration is greater than [P02-13], the first gain is returned. 560 - 561 - 562 562 ))) 563 563 |=(% style="text-align: center; vertical-align: middle" %)4|(% style="text-align:center; vertical-align:middle" %)Large speed command|((( 564 564 In the previous first gain, when the absolute value of speed command is greater than (grade + hysteresis), the second gain is switched; 565 565 566 566 In the previous second gain, when the absolute value of speed command is less than the value of (grade - hysteresis) and the duration is greater than [P02-13], the first gain is returned. 567 - 568 - 569 569 ))) 570 570 |=(% style="text-align: center; vertical-align: middle" %)5|(% style="text-align:center; vertical-align:middle" %)Large actual speed|((( 571 571 In the previous first gain, when the absolute value of actual speed is greater than (grade + hysteresis), the second gain is switched; 572 572 573 573 In the previous second gain, when the absolute value of actual speed is less than the value of (grade - hysteresis) and the duration is greater than [P02-13], the first gain is returned. 574 - 575 - 576 576 ))) 577 577 |=(% style="text-align: center; vertical-align: middle" %)6|(% style="text-align:center; vertical-align:middle" %)Large rate of change in speed command|((( 578 578 In the previous first gain, when the absolute value of the rate of change in speed command is greater than (grade + hysteresis), the second gain is switched; 579 579 580 -In the previous second gain, switch to the first gain when the absolute value of the rate of change in speed command is less than the value of (grade - hysteresis) and the duration is greater than [P02-13], the first gain is returned. 581 - 582 - 572 +In the previous second gain, switch to the first gain when the absolute value of the rate of change in speed command is less than the value of (grade - hysteresis) and the duration is greater than [P02-13], the first gain is returned. 583 583 ))) 584 584 |=(% style="text-align: center; vertical-align: middle" %)7|(% style="text-align:center; vertical-align:middle" %)Large position deviation|((( 585 585 In the previous first gain, when the absolute value of position deviation is greater than (grade + hysteresis), the second gain is switched; ... ... @@ -598,14 +598,12 @@ 598 598 In the previous first gain, if the position command is not 0, the second gain is switched; 599 599 600 600 In the previous second gain, if the position command is 0, the duration is greater than [P02-13] and the absolute value of actual speed is less than ( grade - hysteresis). 601 - 602 -))) 603 603 ))) 592 +))) 604 604 605 -|(% rowspan="2" %) 606 -**P02-13**|**Parameter name**|**Setting method**|**Effective time**|**Default**|**Set range**|**Application category**|**Unit** 607 -|Delay Time for Gain Switching|Operation setting|Effective immediately|20|0 to 10000|Gain control|0.1ms 608 -|(% colspan="8" %)((( 594 +|=(% rowspan="2" style="text-align:center; vertical-align:middle; width:120px" %)**P02-13**|=(% style="width:150px" %)Parameter name|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Setting method**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Effective time**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Default**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Set range**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Application category**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Unit** 595 +|(% style="text-align:center; width:150px" %)Delay Time for Gain Switching|(% style="text-align:center" %)Operation setting|(% style="text-align:center" %)Effective immediately|(% style="text-align:center" %)20|(% style="text-align:center" %)0 to 10000|(% style="text-align:center" %)Gain control|(% style="text-align:center" %)0.1ms 596 +|(% colspan="8" style="text-align:center; vertical-align:middle" %)((( 609 609 The duration of the switching condition required for the second gain to switch back to the first gain. 610 610 611 611 [[image:image-20230515140953-9.png]] ... ... @@ -613,31 +613,28 @@ 613 613 **✎**Note: This parameter is only valid when the second gain is switched back to the first gain. 614 614 ))) 615 615 616 -|(% rowspan="2" %) 617 -**P02-14**|**Parameter name**|**Setting method**|**Effective time**|**Default**|**Set range**|**Application category**|**Unit** 618 -|Gain switching grade|Operation setting|Effective immediately|50|0 to 20000|Gain control|According to the switching conditions 619 -|(% colspan="8" %)((( 604 +|=(% rowspan="2" style="text-align:center; vertical-align:middle; width:120px" %)**P02-14**|=(% style="width:150px" %)Parameter name|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Setting method**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Effective time**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Default**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Set range**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Application category**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Unit** 605 +|(% style="text-align:center; width:150px" %)Gain switching grade|(% style="text-align:center" %)Operation setting|(% style="text-align:center" %)Effective immediately|(% style="text-align:center" %)50|(% style="text-align:center" %)0 to 20000|(% style="text-align:center" %)Gain control|(% style="text-align:center" %)According to the switching conditions 606 +|(% colspan="8" style="text-align:center; vertical-align:middle" %)((( 620 620 Set the grade of the gain condition. The generation of the actual switching action is affected by the two conditions of grade and hysteresis. 621 621 622 622 [[image:image-20230515140953-10.png]] 623 623 ))) 624 624 625 -|(% rowspan="2" %) 626 -**P02-15**|**Parameter name**|**Setting method**|**Effective time**|**Default**|**Set range**|**Application category**|**Unit** 627 -|Gain switching hysteresis|Operation setting|Effective immediately|20|0 to 20000|Gain control|According to the switching conditions 628 -|(% colspan="8" %)((( 612 +|=(% rowspan="2" style="text-align:center; vertical-align:middle; width:120px" %)**P02-15**|=(% style="width:150px" %)Parameter name|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Setting method**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Effective time**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Default**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Set range**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Application category**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Unit** 613 +|(% style="text-align:center; width:150px" %)Gain switching hysteresis|(% style="text-align:center" %)Operation setting|(% style="text-align:center" %)Effective immediately|(% style="text-align:center" %)20|(% style="text-align:center" %)0 to 20000|(% style="text-align:center" %)Gain control|(% style="text-align:center" %)According to the switching conditions 614 +|(% colspan="8" style="text-align:center; vertical-align:middle" %)((( 629 629 Set the hysteresis to meet the gain switching condition. 630 630 631 631 [[image:image-20230515140953-11.png]] 632 632 ))) 633 633 634 -|(% rowspan="2" %) 635 -**P02-16**|**Parameter name**|**Setting method**|**Effective time**|**Default**|**Set range**|**Application category**|**Unit** 636 -|Position loop gain switching time|Operation setting|Effective immediately|30|0 to 10000|Gain control|0.1ms 637 -|(% colspan="8" %)((( 620 +|=(% rowspan="2" style="text-align:center; vertical-align:middle; width:120px" %)**P02-16**|=(% style="width:150px" %)Parameter name|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Setting method**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Effective time**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Default**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Set range**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Application category**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Unit** 621 +|(% style="text-align:center; width:150px" %)Position loop gain switching time|(% style="text-align:center" %)Operation setting|(% style="text-align:center" %)Effective immediately|(% style="text-align:center" %)30|(% style="text-align:center" %)0 to 10000|(% style="text-align:center" %)Gain control|(% style="text-align:center" %)0.1ms 622 +|(% colspan="8" style="text-align:center; vertical-align:middle" %)((( 638 638 Set the time for switching from the first position loop (P02-01) to the second position loop (P02-04) in the position control mode. 639 639 640 -[[image:image-20230515140953-12.png]] 625 +[[image:image-20230515140953-12.png]]| 641 641 642 642 If P02-04≤P02-01, then P02-16 is invalid, and the second gain is switched from the first gain immediately. 643 643 ))) ... ... @@ -1193,3 +1193,14 @@ 1193 1193 1194 1194 Table 7-11 Notch filter function code parameters 1195 1195 ~)~)~) 1181 + 1182 +**Low frequency vibration suppression** 1183 + 1184 +Low-frequency vibration suppression is suitable for working conditions where the motor vibrates during deceleration and shutdown after the position command is sent, and the vibration amplitude gradually decreases. The use of the low-frequency vibration suppression function is effective in reducing the time to complete positioning due to vibration effects. 1185 + 1186 +(% style="text-align:center" %) 1187 +((( 1188 +(% class="wikigeneratedid img-thumbnail" style="display:inline-block" %) 1189 +[[**Figure 7-13 Applicable working conditions for low-frequency vibration suppression**>>image:20230516-0713.png||id="20230516-0713.png"]] 1190 +))) 1191 +
- 20230516-0713.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Karen - Size
-
... ... @@ -1,0 +1,1 @@ 1 +8.4 KB - Content