Changes for page 07 Adjustments
Last modified by Iris on 2025/07/24 11:03
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -539,7 +539,8 @@ 539 539 540 540 |=(% style="text-align: center; vertical-align: middle; width:120px" %)Setting value|=(% style="text-align: center; vertical-align: middle" %)Gain switching conditions|=(% style="text-align: center; vertical-align: middle" %)Details 541 541 |=(% style="text-align: center; vertical-align: middle" %)0|(% style="text-align:center; vertical-align:middle" %)The default is the first gain|Fixed use of the first gain 542 -|=(% style="text-align: center; vertical-align: middle" %)1|(% style="text-align:center; vertical-align:middle" %)Switch by DI port|((( 542 +|=(% style="text-align: center; vertical-align: middle" %)1|(% style="text-align:center; vertical-align:middle" %)Switch by DI port| 543 +((( 543 543 Use DI function 10 (GAIN-SEL, gain switching); 544 544 545 545 DI logic is invalid: the first gain (P02-01~~P02-03); ... ... @@ -546,6 +546,7 @@ 546 546 547 547 DI logic is valid: the second gain (P02-04~~P02-06). 548 548 ))) 550 + 549 549 |=(% style="text-align: center; vertical-align: middle" %)2|(% style="text-align:center; vertical-align:middle" %)Large torque command|((( 550 550 In the previous first gain, when the absolute value of torque command is greater than (grade + hysteresis), the second gain is switched; 551 551