539 539  
540 540  |=(% style="text-align: center; vertical-align: middle; width:120px" %)Setting value|=(% style="text-align: center; vertical-align: middle" %)Gain switching conditions|=(% style="text-align: center; vertical-align: middle" %)Details
541 541  |=(% style="text-align: center; vertical-align: middle" %)0|(% style="text-align:center; vertical-align:middle" %)The default is the first gain|Fixed use of the first gain
542 -|=(% style="text-align: center; vertical-align: middle" %)1|(% style="text-align:center; vertical-align:middle" %)Switch by DI port|
543 -(((
542 +|=(% style="text-align: center; vertical-align: middle" %)1|(% style="text-align:center; vertical-align:middle" %)Switch by DI port|(((
544 544  Use DI function 10 (GAIN-SEL, gain switching);
545 545  
546 546  DI logic is invalid: the first gain (P02-01~~P02-03);
... ... @@ -547,7 +547,6 @@
547 547  
548 548  DI logic is valid: the second gain (P02-04~~P02-06).
549 549  )))
550 -
551 551  |=(% style="text-align: center; vertical-align: middle" %)2|(% style="text-align:center; vertical-align:middle" %)Large torque command|(((
552 552  In the previous first gain, when the absolute value of torque command is greater than (grade + hysteresis), the second gain is switched;
553 553