Changes for page 07 Adjustments
Last modified by Iris on 2025/07/24 11:03
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -539,8 +539,7 @@ 539 539 540 540 |=(% style="text-align: center; vertical-align: middle; width:120px" %)Setting value|=(% style="text-align: center; vertical-align: middle" %)Gain switching conditions|=(% style="text-align: center; vertical-align: middle" %)Details 541 541 |=(% style="text-align: center; vertical-align: middle" %)0|(% style="text-align:center; vertical-align:middle" %)The default is the first gain|Fixed use of the first gain 542 -|=(% style="text-align: center; vertical-align: middle" %)1|(% style="text-align:center; vertical-align:middle" %)Switch by DI port| 543 -((( 542 +|=(% style="text-align: center; vertical-align: middle" %)1|(% style="text-align:center; vertical-align:middle" %)Switch by DI port|((( 544 544 Use DI function 10 (GAIN-SEL, gain switching); 545 545 546 546 DI logic is invalid: the first gain (P02-01~~P02-03); ... ... @@ -551,36 +551,26 @@ 551 551 In the previous first gain, when the absolute value of torque command is greater than (grade + hysteresis), the second gain is switched; 552 552 553 553 In the previous second gain, when the absolute value of torque command is less than the value of (grade - hysteresis) and the duration is greater than [P02-13], the first gain is returned. 554 - 555 - 556 556 ))) 557 557 |=(% style="text-align: center; vertical-align: middle" %)3|(% style="text-align:center; vertical-align:middle" %)Large actual torque|((( 558 558 In the previous first gain, when the absolute value of actual torque is greater than ( grade + hysteresis ), the second gain is switched; 559 559 560 560 In the previous second gain, when the absolute value of actual torque is less than the value of (grade - hysteresis) and the duration is greater than [P02-13], the first gain is returned. 561 - 562 - 563 563 ))) 564 564 |=(% style="text-align: center; vertical-align: middle" %)4|(% style="text-align:center; vertical-align:middle" %)Large speed command|((( 565 565 In the previous first gain, when the absolute value of speed command is greater than (grade + hysteresis), the second gain is switched; 566 566 567 567 In the previous second gain, when the absolute value of speed command is less than the value of (grade - hysteresis) and the duration is greater than [P02-13], the first gain is returned. 568 - 569 - 570 570 ))) 571 571 |=(% style="text-align: center; vertical-align: middle" %)5|(% style="text-align:center; vertical-align:middle" %)Large actual speed|((( 572 572 In the previous first gain, when the absolute value of actual speed is greater than (grade + hysteresis), the second gain is switched; 573 573 574 574 In the previous second gain, when the absolute value of actual speed is less than the value of (grade - hysteresis) and the duration is greater than [P02-13], the first gain is returned. 575 - 576 - 577 577 ))) 578 578 |=(% style="text-align: center; vertical-align: middle" %)6|(% style="text-align:center; vertical-align:middle" %)Large rate of change in speed command|((( 579 579 In the previous first gain, when the absolute value of the rate of change in speed command is greater than (grade + hysteresis), the second gain is switched; 580 580 581 -In the previous second gain, switch to the first gain when the absolute value of the rate of change in speed command is less than the value of (grade - hysteresis) and the duration is greater than [P02-13], the first gain is returned. 582 - 583 - 572 +In the previous second gain, switch to the first gain when the absolute value of the rate of change in speed command is less than the value of (grade - hysteresis) and the duration is greater than [P02-13], the first gain is returned. 584 584 ))) 585 585 |=(% style="text-align: center; vertical-align: middle" %)7|(% style="text-align:center; vertical-align:middle" %)Large position deviation|((( 586 586 In the previous first gain, when the absolute value of position deviation is greater than (grade + hysteresis), the second gain is switched; ... ... @@ -595,17 +595,14 @@ 595 595 |=(% style="text-align: center; vertical-align: middle" %)9|(% style="text-align:center; vertical-align:middle" %)Positioning complete|((( 596 596 In the previous first gain, if the positioning is not completed, the second gain is switched; In the previous second gain, if the positioning is not completed and the duration is greater than [P02-13], the first gain is returned. 597 597 ))) 598 -|=(% style="text-align: center; vertical-align: middle" %)10|(% style="text-align:center; vertical-align:middle" %)Position command + actual speed| 599 -((( 587 +|=(% style="text-align: center; vertical-align: middle" %)10|(% style="text-align:center; vertical-align:middle" %)Position command + actual speed|((( 600 600 In the previous first gain, if the position command is not 0, the second gain is switched; 601 601 602 602 In the previous second gain, if the position command is 0, the duration is greater than [P02-13] and the absolute value of actual speed is less than ( grade - hysteresis). 603 - 604 -))) 605 605 ))) 592 +))) 606 606 607 -|(% rowspan="2" %) 608 -**P02-13**|**Parameter name**|**Setting method**|**Effective time**|**Default**|**Set range**|**Application category**|**Unit** 594 +|=(% rowspan="2" style="text-align:center; vertical-align:middle; width:120px" %) **P02-13**|=(% style="width:150px" %)Parameter name|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Setting method**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Effective time**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Default**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Set range**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Application category**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Unit** 609 609 |Delay Time for Gain Switching|Operation setting|Effective immediately|20|0 to 10000|Gain control|0.1ms 610 610 |(% colspan="8" %)((( 611 611 The duration of the switching condition required for the second gain to switch back to the first gain.