Changes for page 07 Adjustments

Last modified by Iris on 2025/07/24 11:03

From version 40.14
edited by Karen
on 2023/05/16 09:38
Change comment: There is no comment for this version
To version 40.15
edited by Karen
on 2023/05/16 09:40
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -553,45 +553,44 @@
553 553  
554 554  In the previous second gain, when the absolute value of torque command is less than the value of (grade - hysteresis) and the duration is greater than [P02-13], the first gain is returned.
555 555  )))
556 -|=(% style="text-align: center; vertical-align: middle" %)3|(% style="text-align:center; vertical-align:middle" %)Large actual torque|(((
556 +|=(% style="text-align: center; vertical-align: middle" %)3|(% style="text-align:center; vertical-align:middle" %)Large actual torque|
557 +(((
557 557  In the previous first gain, when the absolute value of actual torque is greater than ( grade + hysteresis ), the second gain is switched;
558 558  
559 559  In the previous second gain, when the absolute value of actual torque is less than the value of (grade - hysteresis) and the duration is greater than [P02-13], the first gain is returned.
560 -
561 -
562 562  )))
563 -|=(% style="text-align: center; vertical-align: middle" %)4|(% style="text-align:center; vertical-align:middle" %)Large speed command|(((
562 +|=(% style="text-align: center; vertical-align: middle" %)4|(% style="text-align:center; vertical-align:middle" %)Large speed command|
563 +(((
564 564  In the previous first gain, when the absolute value of speed command is greater than (grade + hysteresis), the second gain is switched;
565 565  
566 566  In the previous second gain, when the absolute value of speed command is less than the value of (grade - hysteresis) and the duration is greater than [P02-13], the first gain is returned.
567 -
568 -
569 569  )))
570 -|=(% style="text-align: center; vertical-align: middle" %)5|(% style="text-align:center; vertical-align:middle" %)Large actual speed|(((
568 +|=(% style="text-align: center; vertical-align: middle" %)5|(% style="text-align:center; vertical-align:middle" %)Large actual speed|
569 +(((
571 571  In the previous first gain, when the absolute value of actual speed is greater than (grade + hysteresis), the second gain is switched;
572 572  
573 573  In the previous second gain, when the absolute value of actual speed is less than the value of (grade - hysteresis) and the duration is greater than [P02-13], the first gain is returned.
574 -
575 -
576 576  )))
577 -|=(% style="text-align: center; vertical-align: middle" %)6|(% style="text-align:center; vertical-align:middle" %)Large rate of change in speed command|(((
574 +|=(% style="text-align: center; vertical-align: middle" %)6|(% style="text-align:center; vertical-align:middle" %)Large rate of change in speed command|
575 +(((
578 578  In the previous first gain, when the absolute value of the rate of change in speed command is greater than (grade + hysteresis), the second gain is switched;
579 579  
580 -In the previous second gain, switch to the first gain when the absolute value of the rate of change in speed command is less than the value of (grade - hysteresis) and the duration is greater than [P02-13], the first gain is returned.
581 -
582 -
578 +In the previous second gain, switch to the first gain when the absolute value of the rate of change in speed command is less than the value of (grade - hysteresis) and the duration is greater than [P02-13], the first gain is returned.
583 583  )))
584 -|=(% style="text-align: center; vertical-align: middle" %)7|(% style="text-align:center; vertical-align:middle" %)Large position deviation|(((
580 +|=(% style="text-align: center; vertical-align: middle" %)7|(% style="text-align:center; vertical-align:middle" %)Large position deviation|
581 +(((
585 585  In the previous first gain, when the absolute value of position deviation is greater than (grade + hysteresis), the second gain is switched;
586 586  
587 587  In the previous second gain, switch to the first gain when the absolute value of position deviation is less than the value of (grade - hysteresis) and the duration is greater than [P02-13], the first gain is returned.
588 588  )))
589 -|=(% style="text-align: center; vertical-align: middle" %)8|(% style="text-align:center; vertical-align:middle" %)Position command|(((
586 +|=(% style="text-align: center; vertical-align: middle" %)8|(% style="text-align:center; vertical-align:middle" %)Position command|
587 +(((
590 590  In the previous first gain, if the position command is not 0, switch to the second gain;
591 591  
592 592  In the previous second gain, if the position command is 0 and the duration is greater than [P02-13], the first gain is returned.
593 593  )))
594 -|=(% style="text-align: center; vertical-align: middle" %)9|(% style="text-align:center; vertical-align:middle" %)Positioning complete|(((
592 +|=(% style="text-align: center; vertical-align: middle" %)9|(% style="text-align:center; vertical-align:middle" %)Positioning complete|
593 +(((
595 595  In the previous first gain, if the positioning is not completed, the second gain is switched; In the previous second gain, if the positioning is not completed and the duration is greater than [P02-13], the first gain is returned.
596 596  )))
597 597  |=(% style="text-align: center; vertical-align: middle" %)10|(% style="text-align:center; vertical-align:middle" %)Position command + actual speed|
... ... @@ -599,9 +599,8 @@
599 599  In the previous first gain, if the position command is not 0, the second gain is switched;
600 600  
601 601  In the previous second gain, if the position command is 0, the duration is greater than [P02-13] and the absolute value of actual speed is less than ( grade - hysteresis).
602 -
603 -)))
604 604  )))
602 +)))
605 605  
606 606  |(% rowspan="2" %)
607 607  **P02-13**|**Parameter name**|**Setting method**|**Effective time**|**Default**|**Set range**|**Application category**|**Unit**