Changes for page 07 Adjustments

Last modified by Iris on 2025/07/24 11:03

From version 40.15
edited by Karen
on 2023/05/16 09:40
Change comment: There is no comment for this version
To version 40.13
edited by Karen
on 2023/05/16 09:38
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -547,50 +547,52 @@
547 547  
548 548  DI logic is valid: the second gain (P02-04~~P02-06).
549 549  )))
550 -|=(% style="text-align: center; vertical-align: middle" %)2|(% style="text-align:center; vertical-align:middle" %)Large torque command|
551 -(((
550 +|=(% style="text-align: center; vertical-align: middle" %)2|(% style="text-align:center; vertical-align:middle" %)Large torque command|(((
552 552  In the previous first gain, when the absolute value of torque command is greater than (grade + hysteresis), the second gain is switched;
553 553  
554 554  In the previous second gain, when the absolute value of torque command is less than the value of (grade - hysteresis) and the duration is greater than [P02-13], the first gain is returned.
554 +
555 +
555 555  )))
556 -|=(% style="text-align: center; vertical-align: middle" %)3|(% style="text-align:center; vertical-align:middle" %)Large actual torque|
557 -(((
557 +|=(% style="text-align: center; vertical-align: middle" %)3|(% style="text-align:center; vertical-align:middle" %)Large actual torque|(((
558 558  In the previous first gain, when the absolute value of actual torque is greater than ( grade + hysteresis ), the second gain is switched;
559 559  
560 560  In the previous second gain, when the absolute value of actual torque is less than the value of (grade - hysteresis) and the duration is greater than [P02-13], the first gain is returned.
561 +
562 +
561 561  )))
562 -|=(% style="text-align: center; vertical-align: middle" %)4|(% style="text-align:center; vertical-align:middle" %)Large speed command|
563 -(((
564 +|=(% style="text-align: center; vertical-align: middle" %)4|(% style="text-align:center; vertical-align:middle" %)Large speed command|(((
564 564  In the previous first gain, when the absolute value of speed command is greater than (grade + hysteresis), the second gain is switched;
565 565  
566 566  In the previous second gain, when the absolute value of speed command is less than the value of (grade - hysteresis) and the duration is greater than [P02-13], the first gain is returned.
568 +
569 +
567 567  )))
568 -|=(% style="text-align: center; vertical-align: middle" %)5|(% style="text-align:center; vertical-align:middle" %)Large actual speed|
569 -(((
571 +|=(% style="text-align: center; vertical-align: middle" %)5|(% style="text-align:center; vertical-align:middle" %)Large actual speed|(((
570 570  In the previous first gain, when the absolute value of actual speed is greater than (grade + hysteresis), the second gain is switched;
571 571  
572 572  In the previous second gain, when the absolute value of actual speed is less than the value of (grade - hysteresis) and the duration is greater than [P02-13], the first gain is returned.
575 +
576 +
573 573  )))
574 -|=(% style="text-align: center; vertical-align: middle" %)6|(% style="text-align:center; vertical-align:middle" %)Large rate of change in speed command|
575 -(((
578 +|=(% style="text-align: center; vertical-align: middle" %)6|(% style="text-align:center; vertical-align:middle" %)Large rate of change in speed command|(((
576 576  In the previous first gain, when the absolute value of the rate of change in speed command is greater than (grade + hysteresis), the second gain is switched;
577 577  
578 -In the previous second gain, switch to the first gain when the absolute value of the rate of change in speed command is less than the value of (grade - hysteresis) and the duration is greater than [P02-13], the first gain is returned.
581 +In the previous second gain, switch to the first gain when the absolute value of the rate of change in speed command is less than the value of (grade - hysteresis) and the duration is greater than [P02-13], the first gain is returned.
582 +
583 +
579 579  )))
580 -|=(% style="text-align: center; vertical-align: middle" %)7|(% style="text-align:center; vertical-align:middle" %)Large position deviation|
581 -(((
585 +|=(% style="text-align: center; vertical-align: middle" %)7|(% style="text-align:center; vertical-align:middle" %)Large position deviation|(((
582 582  In the previous first gain, when the absolute value of position deviation is greater than (grade + hysteresis), the second gain is switched;
583 583  
584 584  In the previous second gain, switch to the first gain when the absolute value of position deviation is less than the value of (grade - hysteresis) and the duration is greater than [P02-13], the first gain is returned.
585 585  )))
586 -|=(% style="text-align: center; vertical-align: middle" %)8|(% style="text-align:center; vertical-align:middle" %)Position command|
587 -(((
590 +|=(% style="text-align: center; vertical-align: middle" %)8|(% style="text-align:center; vertical-align:middle" %)Position command|(((
588 588  In the previous first gain, if the position command is not 0, switch to the second gain;
589 589  
590 590  In the previous second gain, if the position command is 0 and the duration is greater than [P02-13], the first gain is returned.
591 591  )))
592 -|=(% style="text-align: center; vertical-align: middle" %)9|(% style="text-align:center; vertical-align:middle" %)Positioning complete|
593 -(((
595 +|=(% style="text-align: center; vertical-align: middle" %)9|(% style="text-align:center; vertical-align:middle" %)Positioning complete|(((
594 594  In the previous first gain, if the positioning is not completed, the second gain is switched; In the previous second gain, if the positioning is not completed and the duration is greater than [P02-13], the first gain is returned.
595 595  )))
596 596  |=(% style="text-align: center; vertical-align: middle" %)10|(% style="text-align:center; vertical-align:middle" %)Position command + actual speed|
... ... @@ -598,8 +598,9 @@
598 598  In the previous first gain, if the position command is not 0, the second gain is switched;
599 599  
600 600  In the previous second gain, if the position command is 0, the duration is greater than [P02-13] and the absolute value of actual speed is less than ( grade - hysteresis).
603 +
604 +)))
601 601  )))
602 -)))
603 603  
604 604  |(% rowspan="2" %)
605 605  **P02-13**|**Parameter name**|**Setting method**|**Effective time**|**Default**|**Set range**|**Application category**|**Unit**