Changes for page 07 Adjustments
Last modified by Iris on 2025/07/24 11:03
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -591,12 +591,16 @@ 591 591 ))) 592 592 ))) 593 593 594 -|=(% rowspan="2" style="text-align:center; vertical-align:middle; width:120px" %) 594 +|=(% rowspan="2" style="text-align:center; vertical-align:middle; width:120px" %)**P02-13**|=(% style="width:150px" %)Parameter name|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Setting method**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Effective time**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Default**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Set range**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Application category**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Unit** 595 595 |(% style="text-align:center; width:150px" %)Delay Time for Gain Switching|(% style="text-align:center" %)Operation setting|(% style="text-align:center" %)Effective immediately|(% style="text-align:center" %)20|(% style="text-align:center" %)0 to 10000|(% style="text-align:center" %)Gain control|(% style="text-align:center" %)0.1ms 596 596 |(% colspan="8" %)((( 597 597 The duration of the switching condition required for the second gain to switch back to the first gain. 598 598 599 -[[image:image-20230515140953-9.png]] 599 +(% style="text-align:center" %) 600 +((( 601 +(% class="wikigeneratedid img-thumbnail" style="display:inline-block" %) 602 +[[image:image-20230515140953-9.png||id="image-20230515140953-9.png"]] 603 +))) 600 600 601 601 (% class="box infomessage" %) 602 602 ((( ... ... @@ -604,8 +604,7 @@ 604 604 ))) 605 605 ))) 606 606 607 -|(% rowspan="2" %) 608 -**P02-14**|**Parameter name**|**Setting method**|**Effective time**|**Default**|**Set range**|**Application category**|**Unit** 611 +|=(% rowspan="2" style="text-align:center; vertical-align:middle; width:120px" %)**P02-14**|=(% style="width:150px" %)Parameter name|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Setting method**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Effective time**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Default**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Set range**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Application category**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Unit** 609 609 |Gain switching grade|Operation setting|Effective immediately|50|0 to 20000|Gain control|According to the switching conditions 610 610 |(% colspan="8" %)((( 611 611 Set the grade of the gain condition. The generation of the actual switching action is affected by the two conditions of grade and hysteresis. ... ... @@ -613,8 +613,7 @@ 613 613 [[image:image-20230515140953-10.png]] 614 614 ))) 615 615 616 -|(% rowspan="2" %) 617 -**P02-15**|**Parameter name**|**Setting method**|**Effective time**|**Default**|**Set range**|**Application category**|**Unit** 619 +|=(% rowspan="2" style="text-align:center; vertical-align:middle; width:120px" %)**P02-15**|=(% style="width:150px" %)Parameter name|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Setting method**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Effective time**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Default**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Set range**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Application category**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Unit** 618 618 |Gain switching hysteresis|Operation setting|Effective immediately|20|0 to 20000|Gain control|According to the switching conditions 619 619 |(% colspan="8" %)((( 620 620 Set the hysteresis to meet the gain switching condition. ... ... @@ -622,9 +622,7 @@ 622 622 [[image:image-20230515140953-11.png]] 623 623 ))) 624 624 625 -|(% rowspan="2" %) 626 -**P02-16**|**Parameter name**|**Setting method**|**Effective time**|**Default**|**Set range**|**Application category**|**Unit** 627 -|Position loop gain switching time|Operation setting|Effective immediately|30|0 to 10000|Gain control|0.1ms 627 +|=(% rowspan="2" style="text-align:center; vertical-align:middle; width:120px" %)**P02-16**|=(% style="width:150px" %)Parameter name|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Setting method**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Effective time**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Default**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Set range**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Application category**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Unit**|Position loop gain switching time|Operation setting|Effective immediately|30|0 to 10000|Gain control|0.1ms 628 628 |(% colspan="8" %)((( 629 629 Set the time for switching from the first position loop (P02-01) to the second position loop (P02-04) in the position control mode. 630 630