Changes for page 07 Adjustments
Last modified by Iris on 2025/07/24 11:03
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -538,8 +538,8 @@ 538 538 Set the conditions for gain switching. 539 539 540 540 |=(% style="text-align: center; vertical-align: middle; width:120px" %)Setting value|=(% style="text-align: center; vertical-align: middle" %)Gain switching conditions|=(% style="text-align: center; vertical-align: middle" %)Details 541 -|=(% style="text-align: center; vertical-align: middle" %)0| =(% style="text-align:542 -|=(% style="text-align: center; vertical-align: middle" %)1| =(% style="text-align:541 +|=(% style="text-align: center; vertical-align: middle" %)0|(% style="text-align:center; vertical-align:middle" %)The default is the first gain|Fixed use of the first gain 542 +|=(% style="text-align: center; vertical-align: middle" %)1|(% style="text-align:center; vertical-align:middle" %)Switch by DI port|((( 543 543 Use DI function 10 (GAIN-SEL, gain switching); 544 544 545 545 DI logic is invalid: the first gain (P02-01~~P02-03); ... ... @@ -546,110 +546,63 @@ 546 546 547 547 DI logic is valid: the second gain (P02-04~~P02-06). 548 548 ))) 549 -| 2|=(% style="text-align: center; vertical-align: middle" %)Large torque command|(((549 +|=(% style="text-align: center; vertical-align: middle" %)2|(% style="text-align:center; vertical-align:middle" %)Large torque command|((( 550 550 In the previous first gain, when the absolute value of torque command is greater than (grade + hysteresis), the second gain is switched; 551 551 552 552 In the previous second gain, when the absolute value of torque command is less than the value of (grade - hysteresis) and the duration is greater than [P02-13], the first gain is returned. 553 - 554 - 555 555 ))) 556 -| 3|=(% style="text-align: center; vertical-align: middle" %)Large actual torque|(((554 +|=(% style="text-align: center; vertical-align: middle" %)3|(% style="text-align:center; vertical-align:middle" %)Large actual torque|((( 557 557 In the previous first gain, when the absolute value of actual torque is greater than ( grade + hysteresis ), the second gain is switched; 558 558 559 559 In the previous second gain, when the absolute value of actual torque is less than the value of (grade - hysteresis) and the duration is greater than [P02-13], the first gain is returned. 560 - 561 - 562 562 ))) 563 -| 4|=(% style="text-align: center; vertical-align: middle" %)Large speed command|(((559 +|=(% style="text-align: center; vertical-align: middle" %)4|(% style="text-align:center; vertical-align:middle" %)Large speed command|((( 564 564 In the previous first gain, when the absolute value of speed command is greater than (grade + hysteresis), the second gain is switched; 565 565 566 566 In the previous second gain, when the absolute value of speed command is less than the value of (grade - hysteresis) and the duration is greater than [P02-13], the first gain is returned. 567 - 568 - 569 569 ))) 570 -| 5|=(% style="text-align: center; vertical-align: middle" %)Large actual speed|(((564 +|=(% style="text-align: center; vertical-align: middle" %)5|(% style="text-align:center; vertical-align:middle" %)Large actual speed|((( 571 571 In the previous first gain, when the absolute value of actual speed is greater than (grade + hysteresis), the second gain is switched; 572 572 573 573 In the previous second gain, when the absolute value of actual speed is less than the value of (grade - hysteresis) and the duration is greater than [P02-13], the first gain is returned. 574 - 575 - 576 576 ))) 577 -|((( 578 - 579 - 580 -6 581 -)))|((( 582 -= (% style="text-align: center; vertical-align: middle" %) 583 - (%%) = 584 - 585 -Large rate of change in speed command 586 -)))|((( 569 +|=(% style="text-align: center; vertical-align: middle" %)6|(% style="text-align:center; vertical-align:middle" %)Large rate of change in speed command|((( 587 587 In the previous first gain, when the absolute value of the rate of change in speed command is greater than (grade + hysteresis), the second gain is switched; 588 588 589 -In the previous second gain, switch to the first gain when the absolute value of the rate of change in speed command is less than the value of (grade - hysteresis) and the duration is greater than [P02-13], the first gain is returned. 590 - 591 - 572 +In the previous second gain, switch to the first gain when the absolute value of the rate of change in speed command is less than the value of (grade - hysteresis) and the duration is greater than [P02-13], the first gain is returned. 592 592 ))) 593 -|((( 594 - 595 - 596 -7 597 -)))|((( 598 - 599 - 600 -Large position deviation 601 -)))|((( 574 +|=(% style="text-align: center; vertical-align: middle" %)7|(% style="text-align:center; vertical-align:middle" %)Large position deviation|((( 602 602 In the previous first gain, when the absolute value of position deviation is greater than (grade + hysteresis), the second gain is switched; 603 603 604 -In the previous second gain, switch to the first gain when the absolute value of position deviation is less than the value of (grade - hysteresis) and the duration is greater than [P02-13], the first gain is returned 577 +In the previous second gain, switch to the first gain when the absolute value of position deviation is less than the value of (grade - hysteresis) and the duration is greater than [P02-13], the first gain is returned. 605 605 ))) 606 -|8|Position command|((( 579 +|=(% style="text-align: center; vertical-align: middle" %)8|(% style="text-align:center; vertical-align:middle" %)Position command|((( 607 607 In the previous first gain, if the position command is not 0, switch to the second gain; 608 608 609 609 In the previous second gain, if the position command is 0 and the duration is greater than [P02-13], the first gain is returned. 610 610 ))) 611 -|((( 612 - 613 - 614 -9 615 -)))|((( 616 - 617 - 618 -Positioning complete 619 -)))|((( 584 +|=(% style="text-align: center; vertical-align: middle" %)9|(% style="text-align:center; vertical-align:middle" %)Positioning complete|((( 620 620 In the previous first gain, if the positioning is not completed, the second gain is switched; In the previous second gain, if the positioning is not completed and the duration is greater than [P02-13], the first gain is returned. 621 - 622 - 623 623 ))) 624 -|((( 625 - 626 - 627 -10 628 -)))|((( 629 - 630 - 631 -Position command + actual speed 632 -)))|((( 587 +|=(% style="text-align: center; vertical-align: middle" %)10|(% style="text-align:center; vertical-align:middle" %)Position command + actual speed|((( 633 633 In the previous first gain, if the position command is not 0, the second gain is switched; 634 634 635 635 In the previous second gain, if the position command is 0, the duration is greater than [P02-13] and the absolute value of actual speed is less than ( grade - hysteresis). 636 - 637 - 638 638 ))) 639 - 640 - 641 641 ))) 642 642 643 -|(% rowspan="2" %) 644 -**P02-13**|**Parameter name**|**Setting method**|**Effective time**|**Default**|**Set range**|**Application category**|**Unit** 645 -|Delay Time for Gain Switching|Operation setting|Effective immediately|20|0 to 10000|Gain control|0.1ms 594 +|=(% rowspan="2" style="text-align:center; vertical-align:middle; width:120px" %) **P02-13**|=(% style="width:150px" %)Parameter name|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Setting method**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Effective time**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Default**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Set range**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Application category**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Unit** 595 +|(% style="text-align:center; width:150px" %)Delay Time for Gain Switching|(% style="text-align:center" %)Operation setting|(% style="text-align:center" %)Effective immediately|(% style="text-align:center" %)20|(% style="text-align:center" %)0 to 10000|(% style="text-align:center" %)Gain control|(% style="text-align:center" %)0.1ms 646 646 |(% colspan="8" %)((( 647 647 The duration of the switching condition required for the second gain to switch back to the first gain. 648 648 649 649 [[image:image-20230515140953-9.png]] 650 650 601 +(% class="box infomessage" %) 602 +((( 651 651 **✎**Note: This parameter is only valid when the second gain is switched back to the first gain. 652 652 ))) 605 +))) 653 653 654 654 |(% rowspan="2" %) 655 655 **P02-14**|**Parameter name**|**Setting method**|**Effective time**|**Default**|**Set range**|**Application category**|**Unit**