Changes for page 07 Adjustments
Last modified by Iris on 2025/07/24 11:03
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -521,7 +521,7 @@ 521 521 |(% colspan="8" %)((( 522 522 Set the switching mode of the second gain. 523 523 524 -|=(% style="text-align: center; vertical-align: middle; width:120px" %)**Setting value**|=(% style="text-align: center; vertical-align: middle" %)**Function** 524 +|=(% style="text-align: center; vertical-align: middle; width:120px" %) **Setting value**|=(% style="text-align: center; vertical-align: middle" %)**Function** 525 525 |=(% style="text-align: center; vertical-align: middle" %)0|((( 526 526 The first gain is used by default. Switching using DI function 10 (GAIN-SEL, gain switching): 527 527 ... ... @@ -533,13 +533,13 @@ 533 533 ))) 534 534 535 535 |=(% rowspan="2" style="text-align: center; vertical-align: middle; width:120px" %)**P02-08**|=(% style="width:150px" %)Parameter name|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Setting method**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Effective time**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Default**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Set range**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Application category**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Unit** 536 -| (% style="text-align:center; width:150px" %)Gain switching condition selection|(% style="text-align:center" %)Operation setting|(% style="text-align:center" %)Effective immediately|(% style="text-align:center" %)0|(% style="text-align:center" %)0 to 10|(% style="text-align:center" %)Gain control|536 +|Gain switching condition selection|Operation setting|Effective immediately|0|0 to 10|Gain control| 537 537 |(% colspan="8" %)((( 538 538 Set the conditions for gain switching. 539 539 540 -| =(% style="text-align: center; vertical-align: middle; width:120px" %)Setting value|=(% style="text-align: center; vertical-align: middle" %)Gain switching conditions|=(% style="text-align: center; vertical-align: middle" %)Details541 -| =(% style="text-align: center; vertical-align: middle" %)0|(% style="text-align: center; vertical-align: middle" %)The default is the first gain|Fixed use of the first gain542 -| =(% style="text-align: center; vertical-align: middle" %)1|(% style="text-align: center; vertical-align: middle" %)Switch by DI port|(((540 +|Setting value|Gain switching conditions|Details 541 +|0|The default is the first gain|Fixed use of the first gain 542 +|1|Switch by DI port|((( 543 543 Use DI function 10 (GAIN-SEL, gain switching); 544 544 545 545 DI logic is invalid: the first gain (P02-01~~P02-03); ... ... @@ -546,7 +546,7 @@ 546 546 547 547 DI logic is valid: the second gain (P02-04~~P02-06). 548 548 ))) 549 -| =(% style="text-align: center; vertical-align: middle" %)2|(% style="text-align: center; vertical-align: middle" %)Large torque command|(((549 +|2|Large torque command|((( 550 550 In the previous first gain, when the absolute value of torque command is greater than (grade + hysteresis), the second gain is switched; 551 551 552 552 In the previous second gain, when the absolute value of torque command is less than the value of (grade - hysteresis) and the duration is greater than [P02-13], the first gain is returned. ... ... @@ -553,7 +553,7 @@ 553 553 554 554 555 555 ))) 556 -| =(% style="text-align: center; vertical-align: middle" %)3|(% style="text-align: center; vertical-align: middle" %)Large actual torque|(((556 +|3|Large actual torque|((( 557 557 In the previous first gain, when the absolute value of actual torque is greater than ( grade + hysteresis ), the second gain is switched; 558 558 559 559 In the previous second gain, when the absolute value of actual torque is less than the value of (grade - hysteresis) and the duration is greater than [P02-13], the first gain is returned. ... ... @@ -560,28 +560,32 @@ 560 560 561 561 562 562 ))) 563 -| =(% style="text-align: center; vertical-align: middle" %)4|(% style="text-align: center; vertical-align: middle" %)Large speed command|(((563 +|4|Large speed command|((( 564 564 In the previous first gain, when the absolute value of speed command is greater than (grade + hysteresis), the second gain is switched; 565 565 566 -In the previous second gain, when the absolute value of speed command is less than the value of (grade - hysteresis) and the duration is greater than [P02-13], the first gain is returned. 566 +In the previous second gain, when the absolute value of speed command is less than the value of (grade - hysteresis) and the duration is greater than [P02-13], the first gain is returned . 567 567 568 568 569 569 ))) 570 -| =(% style="text-align: center; vertical-align: middle" %)5|(% style="text-align: center; vertical-align: middle" %)Large actual speed|(((570 +|5|Large actual speed|((( 571 571 In the previous first gain, when the absolute value of actual speed is greater than (grade + hysteresis), the second gain is switched; 572 572 573 -In the previous second gain, when the absolute value of actual speed is less than the value of (grade - hysteresis) and the duration is greater than [P02-13], the first gain is returned. 573 +In the previous second gain, when the absolute value of actual speed is less than the value of (grade - hysteresis) and the duration is greater than [P02-13], the first gain is returned . 574 574 575 575 576 576 ))) 577 -| =(% style="text-align: center; vertical-align: middle" %)6|(((577 +|((( 578 578 579 579 580 +6 581 +)))|((( 582 + 583 + 580 580 Large rate of change in speed command 581 581 )))|((( 582 582 In the previous first gain, when the absolute value of the rate of change in speed command is greater than (grade + hysteresis), the second gain is switched; 583 583 584 -In the previous second gain, switch to the first gain when the absolute value of the rate of change in speed command is less than the value of (grade - hysteresis) and the duration is greater than [P02-13], the first gain is returned. 588 +In the previous second gain, switch to the first gain when the absolute value of the rate of change in speed command is less than the value of (grade - hysteresis) and the duration is greater than [P02-13], the first gain is returned . 585 585 586 586 587 587 )))