Changes for page 07 Adjustments
Last modified by Iris on 2025/07/24 11:03
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -538,8 +538,8 @@ 538 538 Set the conditions for gain switching. 539 539 540 540 |=(% style="text-align: center; vertical-align: middle; width:120px" %)Setting value|=(% style="text-align: center; vertical-align: middle" %)Gain switching conditions|=(% style="text-align: center; vertical-align: middle" %)Details 541 -|=(% style="text-align: center; vertical-align: middle" %)0|(% style="text-align: 542 -|=(% style="text-align: center; vertical-align: middle" %)1|(% style="text-align: 541 +|=(% style="text-align: center; vertical-align: middle" %)0|(% style="text-align:center; vertical-align:middle" %)The default is the first gain|Fixed use of the first gain 542 +|=(% style="text-align: center; vertical-align: middle" %)1|(% style="text-align:center; vertical-align:middle" %)Switch by DI port|((( 543 543 Use DI function 10 (GAIN-SEL, gain switching); 544 544 545 545 DI logic is invalid: the first gain (P02-01~~P02-03); ... ... @@ -546,7 +546,7 @@ 546 546 547 547 DI logic is valid: the second gain (P02-04~~P02-06). 548 548 ))) 549 -|=(% style="text-align: center; vertical-align: middle" %)2|(% style="text-align: 549 +|=(% style="text-align: center; vertical-align: middle" %)2|(% style="text-align:center; vertical-align:middle" %)Large torque command|((( 550 550 In the previous first gain, when the absolute value of torque command is greater than (grade + hysteresis), the second gain is switched; 551 551 552 552 In the previous second gain, when the absolute value of torque command is less than the value of (grade - hysteresis) and the duration is greater than [P02-13], the first gain is returned. ... ... @@ -553,7 +553,7 @@ 553 553 554 554 555 555 ))) 556 -|=(% style="text-align: center; vertical-align: middle" %)3|(% style="text-align: 556 +|=(% style="text-align: center; vertical-align: middle" %)3|(% style="text-align:center; vertical-align:middle" %)Large actual torque|((( 557 557 In the previous first gain, when the absolute value of actual torque is greater than ( grade + hysteresis ), the second gain is switched; 558 558 559 559 In the previous second gain, when the absolute value of actual torque is less than the value of (grade - hysteresis) and the duration is greater than [P02-13], the first gain is returned. ... ... @@ -560,7 +560,7 @@ 560 560 561 561 562 562 ))) 563 -|=(% style="text-align: center; vertical-align: middle" %)4|(% style="text-align: 563 +|=(% style="text-align: center; vertical-align: middle" %)4|(% style="text-align:center; vertical-align:middle" %)Large speed command|((( 564 564 In the previous first gain, when the absolute value of speed command is greater than (grade + hysteresis), the second gain is switched; 565 565 566 566 In the previous second gain, when the absolute value of speed command is less than the value of (grade - hysteresis) and the duration is greater than [P02-13], the first gain is returned. ... ... @@ -567,7 +567,7 @@ 567 567 568 568 569 569 ))) 570 -|=(% style="text-align: center; vertical-align: middle" %)5|(% style="text-align: 570 +|=(% style="text-align: center; vertical-align: middle" %)5|(% style="text-align:center; vertical-align:middle" %)Large actual speed|((( 571 571 In the previous first gain, when the absolute value of actual speed is greater than (grade + hysteresis), the second gain is switched; 572 572 573 573 In the previous second gain, when the absolute value of actual speed is less than the value of (grade - hysteresis) and the duration is greater than [P02-13], the first gain is returned. ... ... @@ -574,11 +574,7 @@ 574 574 575 575 576 576 ))) 577 -|=(% style="text-align: center; vertical-align: middle" %)6|((( 578 - 579 - 580 -Large rate of change in speed command 581 -)))|((( 577 +|=(% style="text-align: center; vertical-align: middle" %)6|(% style="text-align:center; vertical-align:middle" %)Large rate of change in speed command|((( 582 582 In the previous first gain, when the absolute value of the rate of change in speed command is greater than (grade + hysteresis), the second gain is switched; 583 583 584 584 In the previous second gain, switch to the first gain when the absolute value of the rate of change in speed command is less than the value of (grade - hysteresis) and the duration is greater than [P02-13], the first gain is returned. ... ... @@ -585,31 +585,19 @@ 585 585 586 586 587 587 ))) 588 -|((( 589 - 590 - 591 -7 592 -)))|((( 593 - 594 - 595 -Large position deviation 596 -)))|((( 584 +|=(% style="text-align: center; vertical-align: middle" %)7|(% style="text-align:center; vertical-align:middle" %)Large position deviation|((( 597 597 In the previous first gain, when the absolute value of position deviation is greater than (grade + hysteresis), the second gain is switched; 598 598 599 -In the previous second gain, switch to the first gain when the absolute value of position deviation is less than the value of (grade - hysteresis) and the duration is greater than [P02-13], the first gain is returned 587 +In the previous second gain, switch to the first gain when the absolute value of position deviation is less than the value of (grade - hysteresis) and the duration is greater than [P02-13], the first gain is returned. 600 600 ))) 601 -|8|Position command|((( 589 +|=(% style="text-align: center; vertical-align: middle" %)8|(% style="text-align:center; vertical-align:middle" %)Position command|((( 602 602 In the previous first gain, if the position command is not 0, switch to the second gain; 603 603 604 604 In the previous second gain, if the position command is 0 and the duration is greater than [P02-13], the first gain is returned. 605 605 ))) 606 -|((( 594 +|=(% style="text-align: center; vertical-align: middle" %)9|((( 607 607 608 608 609 -9 610 -)))|((( 611 - 612 - 613 613 Positioning complete 614 614 )))|((( 615 615 In the previous first gain, if the positioning is not completed, the second gain is switched; In the previous second gain, if the positioning is not completed and the duration is greater than [P02-13], the first gain is returned. ... ... @@ -616,25 +616,14 @@ 616 616 617 617 618 618 ))) 619 -|((( 620 - 621 - 622 -10 623 -)))|((( 624 - 625 - 626 -Position command + actual speed 627 -)))|((( 603 +|=(% style="text-align: center; vertical-align: middle" %)10|(% style="text-align:center; vertical-align:middle" %)Position command + actual speed|((( 628 628 In the previous first gain, if the position command is not 0, the second gain is switched; 629 629 630 630 In the previous second gain, if the position command is 0, the duration is greater than [P02-13] and the absolute value of actual speed is less than ( grade - hysteresis). 631 - 632 632 608 +))) 633 633 ))) 634 634 635 - 636 -))) 637 - 638 638 |(% rowspan="2" %) 639 639 **P02-13**|**Parameter name**|**Setting method**|**Effective time**|**Default**|**Set range**|**Application category**|**Unit** 640 640 |Delay Time for Gain Switching|Operation setting|Effective immediately|20|0 to 10000|Gain control|0.1ms