... ... @@ -538,8 +538,8 @@
538 538  Set the conditions for gain switching.
539 539  
540 540  |=(% style="text-align: center; vertical-align: middle; width:120px" %)Setting value|=(% style="text-align: center; vertical-align: middle" %)Gain switching conditions|=(% style="text-align: center; vertical-align: middle" %)Details
541 -|=(% style="text-align: center; vertical-align: middle" %)0|(% style="text-align: center; vertical-align: middle" %)The default is the first gain|Fixed use of the first gain
542 -|=(% style="text-align: center; vertical-align: middle" %)1|(% style="text-align: center; vertical-align: middle" %)Switch by DI port|(((
541 +|=(% style="text-align: center; vertical-align: middle" %)0|(% style="text-align:center; vertical-align:middle" %)The default is the first gain|Fixed use of the first gain
542 +|=(% style="text-align: center; vertical-align: middle" %)1|(% style="text-align:center; vertical-align:middle" %)Switch by DI port|(((
543 543  Use DI function 10 (GAIN-SEL, gain switching);
544 544  
545 545  DI logic is invalid: the first gain (P02-01~~P02-03);
... ... @@ -546,7 +546,7 @@
546 546  
547 547  DI logic is valid: the second gain (P02-04~~P02-06).
548 548  )))
549 -|=(% style="text-align: center; vertical-align: middle" %)2|(% style="text-align: center; vertical-align: middle" %)Large torque command|(((
549 +|=(% style="text-align: center; vertical-align: middle" %)2|(% style="text-align:center; vertical-align:middle" %)Large torque command|(((
550 550  In the previous first gain, when the absolute value of torque command is greater than (grade + hysteresis), the second gain is switched;
551 551  
552 552  In the previous second gain, when the absolute value of torque command is less than the value of (grade - hysteresis) and the duration is greater than [P02-13], the first gain is returned.
... ... @@ -553,7 +553,7 @@
553 553  
554 554  
555 555  )))
556 -|=(% style="text-align: center; vertical-align: middle" %)3|(% style="text-align: center; vertical-align: middle" %)Large actual torque|(((
556 +|=(% style="text-align: center; vertical-align: middle" %)3|(% style="text-align:center; vertical-align:middle" %)Large actual torque|(((
557 557  In the previous first gain, when the absolute value of actual torque is greater than ( grade + hysteresis ), the second gain is switched;
558 558  
559 559  In the previous second gain, when the absolute value of actual torque is less than the value of (grade - hysteresis) and the duration is greater than [P02-13], the first gain is returned.
... ... @@ -560,7 +560,7 @@
560 560  
561 561  
562 562  )))
563 -|=(% style="text-align: center; vertical-align: middle" %)4|(% style="text-align: center; vertical-align: middle" %)Large speed command|(((
563 +|=(% style="text-align: center; vertical-align: middle" %)4|(% style="text-align:center; vertical-align:middle" %)Large speed command|(((
564 564  In the previous first gain, when the absolute value of speed command is greater than (grade + hysteresis), the second gain is switched;
565 565  
566 566  In the previous second gain, when the absolute value of speed command is less than the value of (grade - hysteresis) and the duration is greater than [P02-13], the first gain is returned.
... ... @@ -567,7 +567,7 @@
567 567  
568 568  
569 569  )))
570 -|=(% style="text-align: center; vertical-align: middle" %)5|(% style="text-align: center; vertical-align: middle" %)Large actual speed|(((
570 +|=(% style="text-align: center; vertical-align: middle" %)5|(% style="text-align:center; vertical-align:middle" %)Large actual speed|(((
571 571  In the previous first gain, when the absolute value of actual speed is greater than (grade + hysteresis), the second gain is switched;
572 572  
573 573  In the previous second gain, when the absolute value of actual speed is less than the value of (grade - hysteresis) and the duration is greater than [P02-13], the first gain is returned.
... ... @@ -574,11 +574,7 @@
574 574  
575 575  
576 576  )))
577 -|=(% style="text-align: center; vertical-align: middle" %)6|(((
578 -
579 -
580 -Large rate of change in speed command
581 -)))|(((
577 +|=(% style="text-align: center; vertical-align: middle" %)6|(% style="text-align:center; vertical-align:middle" %)Large rate of change in speed command|(((
582 582  In the previous first gain, when the absolute value of the rate of change in speed command is greater than (grade + hysteresis), the second gain is switched;
583 583  
584 584  In the previous second gain, switch to the first gain when the absolute value of the rate of change in speed command is less than the value of (grade - hysteresis) and the duration is greater than [P02-13], the first gain is returned.
... ... @@ -585,31 +585,19 @@
585 585  
586 586  
587 587  )))
588 -|(((
589 -
590 -
591 -7
592 -)))|(((
593 -
594 -
595 -Large position deviation
596 -)))|(((
584 +|=(% style="text-align: center; vertical-align: middle" %)7|(% style="text-align:center; vertical-align:middle" %)Large position deviation|(((
597 597  In the previous first gain, when the absolute value of position deviation is greater than (grade + hysteresis), the second gain is switched;
598 598  
599 -In the previous second gain, switch to the first gain when the absolute value of position deviation is less than the value of (grade - hysteresis) and the duration is greater than [P02-13], the first gain is returned .
587 +In the previous second gain, switch to the first gain when the absolute value of position deviation is less than the value of (grade - hysteresis) and the duration is greater than [P02-13], the first gain is returned.
600 600  )))
601 -|8|Position command|(((
589 +|=(% style="text-align: center; vertical-align: middle" %)8|(% style="text-align:center; vertical-align:middle" %)Position command|(((
602 602  In the previous first gain, if the position command is not 0, switch to the second gain;
603 603  
604 604  In the previous second gain, if the position command is 0 and the duration is greater than [P02-13], the first gain is returned.
605 605  )))
606 -|(((
594 +|=(% style="text-align: center; vertical-align: middle" %)9|(((
607 607  
608 608  
609 -9
610 -)))|(((
611 -
612 -
613 613  Positioning complete
614 614  )))|(((
615 615  In the previous first gain, if the positioning is not completed, the second gain is switched; In the previous second gain, if the positioning is not completed and the duration is greater than [P02-13], the first gain is returned.
... ... @@ -616,25 +616,14 @@
616 616  
617 617  
618 618  )))
619 -|(((
620 -
621 -
622 -10
623 -)))|(((
624 -
625 -
626 -Position command + actual speed
627 -)))|(((
603 +|=(% style="text-align: center; vertical-align: middle" %)10|(% style="text-align:center; vertical-align:middle" %)Position command + actual speed|(((
628 628  In the previous first gain, if the position command is not 0, the second gain is switched;
629 629  
630 630  In the previous second gain, if the position command is 0, the duration is greater than [P02-13] and the absolute value of actual speed is less than ( grade - hysteresis).
631 -
632 632  
608 +)))
633 633  )))
634 634  
635 -
636 -)))
637 -
638 638  |(% rowspan="2" %)
639 639  **P02-13**|**Parameter name**|**Setting method**|**Effective time**|**Default**|**Set range**|**Application category**|**Unit**
640 640  |Delay Time for Gain Switching|Operation setting|Effective immediately|20|0 to 10000|Gain control|0.1ms