Changes for page 07 Adjustments

Last modified by Iris on 2025/07/24 11:03

From version 41.10
edited by Karen
on 2023/05/16 10:10
Change comment: There is no comment for this version
To version 40.18
edited by Karen
on 2023/05/16 09:44
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -463,14 +463,10 @@
463 463  2
464 464  )))|(% style="text-align:center; vertical-align:middle; width:464px" %)(((
465 465  Large torque command
466 -)))|(% style="text-align:center" %)(((
467 -(% class="wikigeneratedid img-thumbnail" style="display:inline-block" %)
468 -[[image:image-20230515140641-1.png||id="image-20230515140641-1.png"]]
469 -)))
466 +)))|(% style="width:946px" %)[[image:image-20230515140641-1.png]]
470 470  |=(% style="text-align:center; vertical-align:middle" %)(((
471 471  3
472 -)))|(% style="text-align:center; vertical-align:middle; width:464px" %)Large actual torque|
473 -(% style="width:946px" %)[[image:image-20230515140641-2.png]]
469 +)))|(% style="text-align:center; vertical-align:middle; width:464px" %)Large actual torque|(% style="width:946px" %)[[image:image-20230515140641-2.png]]
474 474  |=(% style="text-align:center; vertical-align:middle" %)(((
475 475  4
476 476  )))|(% style="text-align:center; vertical-align:middle; width:464px" %)(((
... ... @@ -595,16 +595,12 @@
595 595  )))
596 596  )))
597 597  
598 -|=(% rowspan="2" style="text-align:center; vertical-align:middle; width:120px" %)**P02-13**|=(% style="width:150px" %)Parameter name|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Setting method**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Effective time**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Default**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Set range**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Application category**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Unit**
594 +|=(% rowspan="2" style="text-align:center; vertical-align:middle; width:120px" %) **P02-13**|=(% style="width:150px" %)Parameter name|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Setting method**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Effective time**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Default**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Set range**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Application category**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Unit**
599 599  |(% style="text-align:center; width:150px" %)Delay Time for Gain Switching|(% style="text-align:center" %)Operation setting|(% style="text-align:center" %)Effective immediately|(% style="text-align:center" %)20|(% style="text-align:center" %)0 to 10000|(% style="text-align:center" %)Gain control|(% style="text-align:center" %)0.1ms
600 600  |(% colspan="8" %)(((
601 601  The duration of the switching condition required for the second gain to switch back to the first gain.
602 602  
603 -(% style="text-align:center" %)
604 -(((
605 -(% class="wikigeneratedid img-thumbnail" style="display:inline-block" %)
606 -[[image:image-20230515140953-9.png||id="image-20230515140953-9.png"]]
607 -)))
599 +[[image:image-20230515140953-9.png]]
608 608  
609 609  (% class="box infomessage" %)
610 610  (((
... ... @@ -612,40 +612,31 @@
612 612  )))
613 613  )))
614 614  
615 -|=(% rowspan="2" style="text-align:center; vertical-align:middle; width:120px" %)**P02-14**|=(% style="width:150px" %)Parameter name|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Setting method**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Effective time**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Default**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Set range**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Application category**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Unit**
616 -|(% style="text-align:center; width:150px" %)Gain switching grade|(% style="text-align:center" %)Operation setting|(% style="text-align:center" %)Effective immediately|(% style="text-align:center" %)50|(% style="text-align:center" %)0 to 20000|(% style="text-align:center" %)Gain control|(% style="text-align:center" %)According to the switching conditions
607 +|(% rowspan="2" %)
608 +**P02-14**|**Parameter name**|**Setting method**|**Effective time**|**Default**|**Set range**|**Application category**|**Unit**
609 +|Gain switching grade|Operation setting|Effective immediately|50|0 to 20000|Gain control|According to the switching conditions
617 617  |(% colspan="8" %)(((
618 618  Set the grade of the gain condition. The generation of the actual switching action is affected by the two conditions of grade and hysteresis.
619 619  
620 -(% style="text-align:center" %)
621 -(((
622 -(% class="wikigeneratedid img-thumbnail" style="display:inline-block" %)
623 -[[image:image-20230515140953-10.png||id="image-20230515140953-10.png"]]
613 +[[image:image-20230515140953-10.png]]
624 624  )))
625 -)))
626 626  
627 -|=(% rowspan="2" style="text-align:center; vertical-align:middle; width:120px" %)**P02-15**|=(% style="width:150px" %)Parameter name|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Setting method**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Effective time**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Default**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Set range**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Application category**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Unit**
628 -|(% style="text-align:center; width:150px" %)Gain switching hysteresis|(% style="text-align:center" %)Operation setting|(% style="text-align:center" %)Effective immediately|(% style="text-align:center" %)20|(% style="text-align:center" %)0 to 20000|(% style="text-align:center" %)Gain control|(% style="text-align:center" %)According to the switching conditions
616 +|(% rowspan="2" %)
617 +**P02-15**|**Parameter name**|**Setting method**|**Effective time**|**Default**|**Set range**|**Application category**|**Unit**
618 +|Gain switching hysteresis|Operation setting|Effective immediately|20|0 to 20000|Gain control|According to the switching conditions
629 629  |(% colspan="8" %)(((
630 630  Set the hysteresis to meet the gain switching condition.
631 631  
632 -(% style="text-align:center" %)
633 -(((
634 -(% class="wikigeneratedid img-thumbnail" style="display:inline-block" %)
635 -[[image:image-20230515140953-11.png||id="image-20230515140953-11.png"]]
622 +[[image:image-20230515140953-11.png]]
636 636  )))
637 -)))
638 638  
639 -|=(% rowspan="2" style="text-align:center; vertical-align:middle; width:120px" %)**P02-16**|=(% style="width:150px" %)Parameter name|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Setting method**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Effective time**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Default**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Set range**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Application category**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Unit**
640 -|(% style="text-align:center; width:150px" %)Position loop gain switching time|(% style="text-align:center" %)Operation setting|(% style="text-align:center" %)Effective immediately|(% style="text-align:center" %)30|(% style="text-align:center" %)0 to 10000|(% style="text-align:center" %)Gain control|(% style="text-align:center" %)0.1ms
625 +|(% rowspan="2" %)
626 +**P02-16**|**Parameter name**|**Setting method**|**Effective time**|**Default**|**Set range**|**Application category**|**Unit**
627 +|Position loop gain switching time|Operation setting|Effective immediately|30|0 to 10000|Gain control|0.1ms
641 641  |(% colspan="8" %)(((
642 642  Set the time for switching from the first position loop (P02-01) to the second position loop (P02-04) in the position control mode.
643 643  
644 -(% style="text-align:center" %)
645 -(((
646 -(% class="wikigeneratedid img-thumbnail" style="display:inline-block" %)
647 -[[image:image-20230515140953-12.png||id="image-20230515140953-12.png"]]
648 -)))
631 +[[image:image-20230515140953-12.png]]
649 649  
650 650  If P02-04≤P02-01, then P02-16 is invalid, and the second gain is switched from the first gain immediately.
651 651  )))