Changes for page 07 Adjustments
Last modified by Iris on 2025/07/24 11:03
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -539,7 +539,8 @@ 539 539 540 540 |=(% style="text-align: center; vertical-align: middle; width:120px" %)Setting value|=(% style="text-align: center; vertical-align: middle" %)Gain switching conditions|=(% style="text-align: center; vertical-align: middle" %)Details 541 541 |=(% style="text-align: center; vertical-align: middle" %)0|(% style="text-align:center; vertical-align:middle" %)The default is the first gain|Fixed use of the first gain 542 -|=(% style="text-align: center; vertical-align: middle" %)1|(% style="text-align:center; vertical-align:middle" %)Switch by DI port|((( 542 +|=(% style="text-align: center; vertical-align: middle" %)1|(% style="text-align:center; vertical-align:middle" %)Switch by DI port| 543 +((( 543 543 Use DI function 10 (GAIN-SEL, gain switching); 544 544 545 545 DI logic is invalid: the first gain (P02-01~~P02-03); ... ... @@ -550,26 +550,36 @@ 550 550 In the previous first gain, when the absolute value of torque command is greater than (grade + hysteresis), the second gain is switched; 551 551 552 552 In the previous second gain, when the absolute value of torque command is less than the value of (grade - hysteresis) and the duration is greater than [P02-13], the first gain is returned. 554 + 555 + 553 553 ))) 554 554 |=(% style="text-align: center; vertical-align: middle" %)3|(% style="text-align:center; vertical-align:middle" %)Large actual torque|((( 555 555 In the previous first gain, when the absolute value of actual torque is greater than ( grade + hysteresis ), the second gain is switched; 556 556 557 557 In the previous second gain, when the absolute value of actual torque is less than the value of (grade - hysteresis) and the duration is greater than [P02-13], the first gain is returned. 561 + 562 + 558 558 ))) 559 559 |=(% style="text-align: center; vertical-align: middle" %)4|(% style="text-align:center; vertical-align:middle" %)Large speed command|((( 560 560 In the previous first gain, when the absolute value of speed command is greater than (grade + hysteresis), the second gain is switched; 561 561 562 562 In the previous second gain, when the absolute value of speed command is less than the value of (grade - hysteresis) and the duration is greater than [P02-13], the first gain is returned. 568 + 569 + 563 563 ))) 564 564 |=(% style="text-align: center; vertical-align: middle" %)5|(% style="text-align:center; vertical-align:middle" %)Large actual speed|((( 565 565 In the previous first gain, when the absolute value of actual speed is greater than (grade + hysteresis), the second gain is switched; 566 566 567 567 In the previous second gain, when the absolute value of actual speed is less than the value of (grade - hysteresis) and the duration is greater than [P02-13], the first gain is returned. 575 + 576 + 568 568 ))) 569 569 |=(% style="text-align: center; vertical-align: middle" %)6|(% style="text-align:center; vertical-align:middle" %)Large rate of change in speed command|((( 570 570 In the previous first gain, when the absolute value of the rate of change in speed command is greater than (grade + hysteresis), the second gain is switched; 571 571 572 -In the previous second gain, switch to the first gain when the absolute value of the rate of change in speed command is less than the value of (grade - hysteresis) and the duration is greater than [P02-13], the first gain is returned. 581 +In the previous second gain, switch to the first gain when the absolute value of the rate of change in speed command is less than the value of (grade - hysteresis) and the duration is greater than [P02-13], the first gain is returned. 582 + 583 + 573 573 ))) 574 574 |=(% style="text-align: center; vertical-align: middle" %)7|(% style="text-align:center; vertical-align:middle" %)Large position deviation|((( 575 575 In the previous first gain, when the absolute value of position deviation is greater than (grade + hysteresis), the second gain is switched; ... ... @@ -584,31 +584,28 @@ 584 584 |=(% style="text-align: center; vertical-align: middle" %)9|(% style="text-align:center; vertical-align:middle" %)Positioning complete|((( 585 585 In the previous first gain, if the positioning is not completed, the second gain is switched; In the previous second gain, if the positioning is not completed and the duration is greater than [P02-13], the first gain is returned. 586 586 ))) 587 -|=(% style="text-align: center; vertical-align: middle" %)10|(% style="text-align:center; vertical-align:middle" %)Position command + actual speed|((( 598 +|=(% style="text-align: center; vertical-align: middle" %)10|(% style="text-align:center; vertical-align:middle" %)Position command + actual speed| 599 +((( 588 588 In the previous first gain, if the position command is not 0, the second gain is switched; 589 589 590 590 In the previous second gain, if the position command is 0, the duration is greater than [P02-13] and the absolute value of actual speed is less than ( grade - hysteresis). 603 + 604 +))) 591 591 ))) 592 -))) 593 593 594 -|=(% rowspan="2" style="text-align:center; vertical-align:middle; width:120px" %)**P02-13**|=(% style="width:150px" %)Parameter name|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Setting method**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Effective time**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Default**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Set range**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Application category**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Unit** 595 -|(% style="text-align:center; width:150px" %)Delay Time for Gain Switching|(% style="text-align:center" %)Operation setting|(% style="text-align:center" %)Effective immediately|(% style="text-align:center" %)20|(% style="text-align:center" %)0 to 10000|(% style="text-align:center" %)Gain control|(% style="text-align:center" %)0.1ms 607 +|(% rowspan="2" %) 608 +**P02-13**|**Parameter name**|**Setting method**|**Effective time**|**Default**|**Set range**|**Application category**|**Unit** 609 +|Delay Time for Gain Switching|Operation setting|Effective immediately|20|0 to 10000|Gain control|0.1ms 596 596 |(% colspan="8" %)((( 597 597 The duration of the switching condition required for the second gain to switch back to the first gain. 598 598 599 -(% style="text-align:center" %) 600 -((( 601 -(% class="wikigeneratedid img-thumbnail" style="display:inline-block" %) 602 -[[image:image-20230515140953-9.png||id="image-20230515140953-9.png"]] 603 -))) 613 +[[image:image-20230515140953-9.png]] 604 604 605 -(% class="box infomessage" %) 606 -((( 607 607 **✎**Note: This parameter is only valid when the second gain is switched back to the first gain. 608 608 ))) 609 -))) 610 610 611 -|=(% rowspan="2" style="text-align:center; vertical-align:middle; width:120px" %)**P02-14**|=(% style="width:150px" %)Parameter name|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Setting method**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Effective time**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Default**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Set range**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Application category**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Unit** 618 +|(% rowspan="2" %) 619 +**P02-14**|**Parameter name**|**Setting method**|**Effective time**|**Default**|**Set range**|**Application category**|**Unit** 612 612 |Gain switching grade|Operation setting|Effective immediately|50|0 to 20000|Gain control|According to the switching conditions 613 613 |(% colspan="8" %)((( 614 614 Set the grade of the gain condition. The generation of the actual switching action is affected by the two conditions of grade and hysteresis. ... ... @@ -616,7 +616,8 @@ 616 616 [[image:image-20230515140953-10.png]] 617 617 ))) 618 618 619 -|=(% rowspan="2" style="text-align:center; vertical-align:middle; width:120px" %)**P02-15**|=(% style="width:150px" %)Parameter name|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Setting method**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Effective time**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Default**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Set range**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Application category**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Unit** 627 +|(% rowspan="2" %) 628 +**P02-15**|**Parameter name**|**Setting method**|**Effective time**|**Default**|**Set range**|**Application category**|**Unit** 620 620 |Gain switching hysteresis|Operation setting|Effective immediately|20|0 to 20000|Gain control|According to the switching conditions 621 621 |(% colspan="8" %)((( 622 622 Set the hysteresis to meet the gain switching condition. ... ... @@ -624,7 +624,9 @@ 624 624 [[image:image-20230515140953-11.png]] 625 625 ))) 626 626 627 -|=(% rowspan="2" style="text-align:center; vertical-align:middle; width:120px" %)**P02-16**|=(% style="width:150px" %)Parameter name|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Setting method**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Effective time**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Default**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Set range**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Application category**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Unit**|Position loop gain switching time|Operation setting|Effective immediately|30|0 to 10000|Gain control|0.1ms 636 +|(% rowspan="2" %) 637 +**P02-16**|**Parameter name**|**Setting method**|**Effective time**|**Default**|**Set range**|**Application category**|**Unit** 638 +|Position loop gain switching time|Operation setting|Effective immediately|30|0 to 10000|Gain control|0.1ms 628 628 |(% colspan="8" %)((( 629 629 Set the time for switching from the first position loop (P02-01) to the second position loop (P02-04) in the position control mode. 630 630