Summary

Details

Page properties
Content
... ... @@ -613,8 +613,12 @@
613 613  |(% colspan="8" %)(((
614 614  Set the grade of the gain condition. The generation of the actual switching action is affected by the two conditions of grade and hysteresis.
615 615  
616 -[[image:image-20230515140953-10.png]]
616 +(% style="text-align:center" %)
617 +(((
618 +(% class="wikigeneratedid img-thumbnail" style="display:inline-block" %)
619 +[[image:image-20230515140953-10.png||id="image-20230515140953-10.png"]]
617 617  )))
621 +)))
618 618  
619 619  |=(% rowspan="2" style="text-align:center; vertical-align:middle; width:120px" %)**P02-15**|=(% style="width:150px" %)Parameter name|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Setting method**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Effective time**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Default**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Set range**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Application category**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Unit**
620 620  |Gain switching hysteresis|Operation setting|Effective immediately|20|0 to 20000|Gain control|According to the switching conditions
... ... @@ -621,14 +621,23 @@
621 621  |(% colspan="8" %)(((
622 622  Set the hysteresis to meet the gain switching condition.
623 623  
624 -[[image:image-20230515140953-11.png]]
628 +(% style="text-align:center" %)
629 +(((
630 +(% class="wikigeneratedid img-thumbnail" style="display:inline-block" %)
631 +[[image:image-20230515140953-11.png||id="image-20230515140953-11.png"]]
625 625  )))
633 +)))
626 626  
627 -|=(% rowspan="2" style="text-align:center; vertical-align:middle; width:120px" %)**P02-16**|=(% style="width:150px" %)Parameter name|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Setting method**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Effective time**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Default**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Set range**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Application category**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Unit**|Position loop gain switching time|Operation setting|Effective immediately|30|0 to 10000|Gain control|0.1ms
635 +|=(% rowspan="2" style="text-align:center; vertical-align:middle; width:120px" %)**P02-16**|=(% style="width:150px" %)Parameter name|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Setting method**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Effective time**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Default**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Set range**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Application category**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Unit**
636 +|Position loop gain switching time|Operation setting|Effective immediately|30|0 to 10000|Gain control|0.1ms
628 628  |(% colspan="8" %)(((
629 629  Set the time for switching from the first position loop (P02-01) to the second position loop (P02-04) in the position control mode.
630 630  
631 -[[image:image-20230515140953-12.png]]
640 +(% style="text-align:center" %)
641 +(((
642 +(% class="wikigeneratedid img-thumbnail" style="display:inline-block" %)
643 +[[image:image-20230515140953-12.png||id="image-20230515140953-12.png"]]
644 +)))
632 632  
633 633  If P02-04≤P02-01, then P02-16 is invalid, and the second gain is switched from the first gain immediately.
634 634  )))