Changes for page 07 Adjustments
Last modified by Iris on 2025/07/24 11:03
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -591,24 +591,18 @@ 591 591 ))) 592 592 ))) 593 593 594 -|=(% rowspan="2" style="text-align:center; vertical-align:middle; width:120px" %)**P02-13**|=(% style="width:150px" %)Parameter name|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Setting method**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Effective time**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Default**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Set range**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Application category**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Unit** 595 -| (% style="text-align:center; width:150px" %)Delay Time for Gain Switching|(% style="text-align:center" %)Operation setting|(% style="text-align:center" %)Effective immediately|(% style="text-align:center" %)20|(% style="text-align:center" %)0 to 10000|(% style="text-align:center" %)Gain control|(% style="text-align:center" %)0.1ms594 +|=(% rowspan="2" style="text-align:center; vertical-align:middle; width:120px" %) **P02-13**|=(% style="width:150px" %)Parameter name|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Setting method**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Effective time**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Default**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Set range**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Application category**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Unit** 595 +|Delay Time for Gain Switching|Operation setting|Effective immediately|20|0 to 10000|Gain control|0.1ms 596 596 |(% colspan="8" %)((( 597 597 The duration of the switching condition required for the second gain to switch back to the first gain. 598 598 599 -(% style="text-align:center" %) 600 -((( 601 -(% class="wikigeneratedid img-thumbnail" style="display:inline-block" %) 602 -[[image:image-20230515140953-9.png||id="image-20230515140953-9.png"]] 603 -))) 599 +[[image:image-20230515140953-9.png]] 604 604 605 -(% class="box infomessage" %) 606 -((( 607 607 **✎**Note: This parameter is only valid when the second gain is switched back to the first gain. 608 608 ))) 609 -))) 610 610 611 -|=(% rowspan="2" style="text-align:center; vertical-align:middle; width:120px" %)**P02-14**|=(% style="width:150px" %)Parameter name|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Setting method**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Effective time**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Default**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Set range**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Application category**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Unit** 604 +|(% rowspan="2" %) 605 +**P02-14**|**Parameter name**|**Setting method**|**Effective time**|**Default**|**Set range**|**Application category**|**Unit** 612 612 |Gain switching grade|Operation setting|Effective immediately|50|0 to 20000|Gain control|According to the switching conditions 613 613 |(% colspan="8" %)((( 614 614 Set the grade of the gain condition. The generation of the actual switching action is affected by the two conditions of grade and hysteresis. ... ... @@ -616,7 +616,8 @@ 616 616 [[image:image-20230515140953-10.png]] 617 617 ))) 618 618 619 -|=(% rowspan="2" style="text-align:center; vertical-align:middle; width:120px" %)**P02-15**|=(% style="width:150px" %)Parameter name|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Setting method**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Effective time**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Default**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Set range**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Application category**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Unit** 613 +|(% rowspan="2" %) 614 +**P02-15**|**Parameter name**|**Setting method**|**Effective time**|**Default**|**Set range**|**Application category**|**Unit** 620 620 |Gain switching hysteresis|Operation setting|Effective immediately|20|0 to 20000|Gain control|According to the switching conditions 621 621 |(% colspan="8" %)((( 622 622 Set the hysteresis to meet the gain switching condition. ... ... @@ -624,7 +624,8 @@ 624 624 [[image:image-20230515140953-11.png]] 625 625 ))) 626 626 627 -|=(% rowspan="2" style="text-align:center; vertical-align:middle; width:120px" %)**P02-16**|=(% style="width:150px" %)Parameter name|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Setting method**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Effective time**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Default**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Set range**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Application category**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Unit** 622 +|(% rowspan="2" %) 623 +**P02-16**|**Parameter name**|**Setting method**|**Effective time**|**Default**|**Set range**|**Application category**|**Unit** 628 628 |Position loop gain switching time|Operation setting|Effective immediately|30|0 to 10000|Gain control|0.1ms 629 629 |(% colspan="8" %)((( 630 630 Set the time for switching from the first position loop (P02-01) to the second position loop (P02-04) in the position control mode.