Changes for page 07 Adjustments
Last modified by Iris on 2025/07/24 11:03
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -463,10 +463,12 @@ 463 463 2 464 464 )))|(% style="text-align:center; vertical-align:middle; width:464px" %)((( 465 465 Large torque command 466 -)))|(% style="width:946px" %)[[image:image-20230515140641-1.png]] 466 +)))|(% style="text-align:center; vertical-align:middle" %)[[image:image-20230515140641-1.png]] 467 + 467 467 |=(% style="text-align:center; vertical-align:middle" %)((( 468 468 3 469 -)))|(% style="text-align:center; vertical-align:middle; width:464px" %)Large actual torque|(% style="width:946px" %)[[image:image-20230515140641-2.png]] 470 +)))|(% style="text-align:center; vertical-align:middle; width:464px" %)Large actual torque| 471 +(% style="width:946px" %)[[image:image-20230515140641-2.png]] 470 470 |=(% style="text-align:center; vertical-align:middle" %)((( 471 471 4 472 472 )))|(% style="text-align:center; vertical-align:middle; width:464px" %)((( ... ... @@ -483,7 +483,11 @@ 483 483 6 484 484 )))|(% style="text-align:center; vertical-align:middle; width:464px" %)((( 485 485 Speed command change rate is large 486 -)))|(% style="width:946px" %)[[image:image-20230515140641-5.png]] 488 +)))| (% style="text-align:center" %) 489 +((( 490 +(% class="wikigeneratedid img-thumbnail" style="display:inline-block" %) 491 +[[image:image-20230515140641-5.png||id="image-20230515140641-5.png"]] 492 +)))(% style="width:946px" %)[[image:image-20230515140641-5.png]] 487 487 |=(% style="width:74px" %)((( 488 488 7 489 489 )))|(% style="text-align:center; vertical-align:middle; width:464px" %)((( ... ... @@ -609,27 +609,39 @@ 609 609 ))) 610 610 611 611 |=(% rowspan="2" style="text-align:center; vertical-align:middle; width:120px" %)**P02-14**|=(% style="width:150px" %)Parameter name|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Setting method**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Effective time**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Default**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Set range**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Application category**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Unit** 612 -|Gain switching grade|Operation setting|Effective immediately|50|0 to 20000|Gain control|According to the switching conditions 618 +|(% style="text-align:center; width:150px" %)Gain switching grade|(% style="text-align:center" %)Operation setting|(% style="text-align:center" %)Effective immediately|(% style="text-align:center" %)50|(% style="text-align:center" %)0 to 20000|(% style="text-align:center" %)Gain control|(% style="text-align:center" %)According to the switching conditions 613 613 |(% colspan="8" %)((( 614 614 Set the grade of the gain condition. The generation of the actual switching action is affected by the two conditions of grade and hysteresis. 615 615 616 -[[image:image-20230515140953-10.png]] 622 +(% style="text-align:center" %) 623 +((( 624 +(% class="wikigeneratedid img-thumbnail" style="display:inline-block" %) 625 +[[image:image-20230515140953-10.png||id="image-20230515140953-10.png"]] 617 617 ))) 627 +))) 618 618 619 619 |=(% rowspan="2" style="text-align:center; vertical-align:middle; width:120px" %)**P02-15**|=(% style="width:150px" %)Parameter name|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Setting method**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Effective time**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Default**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Set range**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Application category**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Unit** 620 -|Gain switching hysteresis|Operation setting|Effective immediately|20|0 to 20000|Gain control|According to the switching conditions 630 +|(% style="text-align:center; width:150px" %)Gain switching hysteresis|(% style="text-align:center" %)Operation setting|(% style="text-align:center" %)Effective immediately|(% style="text-align:center" %)20|(% style="text-align:center" %)0 to 20000|(% style="text-align:center" %)Gain control|(% style="text-align:center" %)According to the switching conditions 621 621 |(% colspan="8" %)((( 622 622 Set the hysteresis to meet the gain switching condition. 623 623 624 -[[image:image-20230515140953-11.png]] 634 +(% style="text-align:center" %) 635 +((( 636 +(% class="wikigeneratedid img-thumbnail" style="display:inline-block" %) 637 +[[image:image-20230515140953-11.png||id="image-20230515140953-11.png"]] 625 625 ))) 639 +))) 626 626 627 627 |=(% rowspan="2" style="text-align:center; vertical-align:middle; width:120px" %)**P02-16**|=(% style="width:150px" %)Parameter name|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Setting method**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Effective time**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Default**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Set range**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Application category**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Unit** 628 -|Position loop gain switching time|Operation setting|Effective immediately|30|0 to 10000|Gain control|0.1ms 642 +|(% style="text-align:center; width:150px" %)Position loop gain switching time|(% style="text-align:center" %)Operation setting|(% style="text-align:center" %)Effective immediately|(% style="text-align:center" %)30|(% style="text-align:center" %)0 to 10000|(% style="text-align:center" %)Gain control|(% style="text-align:center" %)0.1ms 629 629 |(% colspan="8" %)((( 630 630 Set the time for switching from the first position loop (P02-01) to the second position loop (P02-04) in the position control mode. 631 631 632 -[[image:image-20230515140953-12.png]] 646 +(% style="text-align:center" %) 647 +((( 648 +(% class="wikigeneratedid img-thumbnail" style="display:inline-block" %) 649 +[[image:image-20230515140953-12.png||id="image-20230515140953-12.png"]] 650 +))) 633 633 634 634 If P02-04≤P02-01, then P02-16 is invalid, and the second gain is switched from the first gain immediately. 635 635 )))