593 593  
594 594  |=(% rowspan="2" style="text-align:center; vertical-align:middle; width:120px" %)**P02-13**|=(% style="width:150px" %)Parameter name|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Setting method**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Effective time**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Default**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Set range**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Application category**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Unit**
595 595  |(% style="text-align:center; width:150px" %)Delay Time for Gain Switching|(% style="text-align:center" %)Operation setting|(% style="text-align:center" %)Effective immediately|(% style="text-align:center" %)20|(% style="text-align:center" %)0 to 10000|(% style="text-align:center" %)Gain control|(% style="text-align:center" %)0.1ms
596 -|(% colspan="8" %)(((
596 +|(% colspan="6" %)(((
597 597  The duration of the switching condition required for the second gain to switch back to the first gain.
598 598  
599 -(% style="text-align:center" %)
600 -(((
601 -(% class="wikigeneratedid img-thumbnail" style="display:inline-block" %)
602 -[[image:image-20230515140953-9.png||id="image-20230515140953-9.png"]]
603 -)))
604 -
605 -(% class="box infomessage" %)
606 -(((
599 +(% style="text-align:center;vertical-align:middle" %)[[image:image-20230515140953-9.png]]
607 607  **✎**Note: This parameter is only valid when the second gain is switched back to the first gain.
608 608  )))
609 -)))
610 610  
611 611  |=(% rowspan="2" style="text-align:center; vertical-align:middle; width:120px" %)**P02-14**|=(% style="width:150px" %)Parameter name|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Setting method**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Effective time**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Default**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Set range**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Application category**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Unit**
612 612  |(% style="text-align:center; width:150px" %)Gain switching grade|(% style="text-align:center" %)Operation setting|(% style="text-align:center" %)Effective immediately|(% style="text-align:center" %)50|(% style="text-align:center" %)0 to 20000|(% style="text-align:center" %)Gain control|(% style="text-align:center" %)According to the switching conditions
... ... @@ -637,7 +637,7 @@
637 637  |(% colspan="8" %)(((
638 638  Set the time for switching from the first position loop (P02-01) to the second position loop (P02-04) in the position control mode.
639 639  
640 -|(% style="text-align:center; vertical-align:middle" %)[[image:image-20230515140953-12.png]]|
632 +|(% style="text-align:center; vertical-align:middle" %)[[image:image-20230515140953-12.png]]|
641 641  
642 642  If P02-04≤P02-01, then P02-16 is invalid, and the second gain is switched from the first gain immediately.
643 643  )))