Changes for page 07 Adjustments

Last modified by Iris on 2025/07/24 11:03

From version 45.5
edited by Karen
on 2023/05/16 10:35
Change comment: There is no comment for this version
To version 47.1
edited by Karen
on 2023/05/16 10:48
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -603,34 +603,26 @@
603 603  
604 604  |=(% rowspan="2" style="text-align:center; vertical-align:middle; width:120px" %)**P02-14**|=(% style="width:150px" %)Parameter name|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Setting method**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Effective time**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Default**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Set range**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Application category**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Unit**
605 605  |(% style="text-align:center; width:150px" %)Gain switching grade|(% style="text-align:center" %)Operation setting|(% style="text-align:center" %)Effective immediately|(% style="text-align:center" %)50|(% style="text-align:center" %)0 to 20000|(% style="text-align:center" %)Gain control|(% style="text-align:center" %)According to the switching conditions
606 -|(% colspan="8" %)(((
606 +|(% colspan="8" style="text-align:center; vertical-align:middle" %)(((
607 607  Set the grade of the gain condition. The generation of the actual switching action is affected by the two conditions of grade and hysteresis.
608 608  
609 -(% style="text-align:center" %)
610 -(((
611 -(% class="wikigeneratedid img-thumbnail" style="display:inline-block" %)
612 -[[image:image-20230515140953-10.png||id="image-20230515140953-10.png"]]
609 +[[image:image-20230515140953-10.png]]
613 613  )))
614 -)))
615 615  
616 616  |=(% rowspan="2" style="text-align:center; vertical-align:middle; width:120px" %)**P02-15**|=(% style="width:150px" %)Parameter name|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Setting method**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Effective time**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Default**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Set range**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Application category**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Unit**
617 617  |(% style="text-align:center; width:150px" %)Gain switching hysteresis|(% style="text-align:center" %)Operation setting|(% style="text-align:center" %)Effective immediately|(% style="text-align:center" %)20|(% style="text-align:center" %)0 to 20000|(% style="text-align:center" %)Gain control|(% style="text-align:center" %)According to the switching conditions
618 -|(% colspan="8" %)(((
614 +|(% colspan="8" style="text-align:center; vertical-align:middle" %)(((
619 619  Set the hysteresis to meet the gain switching condition.
620 620  
621 -(% style="text-align:center" %)
622 -(((
623 -(% class="wikigeneratedid img-thumbnail" style="display:inline-block" %)
624 -[[image:image-20230515140953-11.png||id="image-20230515140953-11.png"]]
617 +[[image:image-20230515140953-11.png]]
625 625  )))
626 -)))
627 627  
628 628  |=(% rowspan="2" style="text-align:center; vertical-align:middle; width:120px" %)**P02-16**|=(% style="width:150px" %)Parameter name|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Setting method**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Effective time**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Default**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Set range**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Application category**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Unit**
629 629  |(% style="text-align:center; width:150px" %)Position loop gain switching time|(% style="text-align:center" %)Operation setting|(% style="text-align:center" %)Effective immediately|(% style="text-align:center" %)30|(% style="text-align:center" %)0 to 10000|(% style="text-align:center" %)Gain control|(% style="text-align:center" %)0.1ms
630 -|(% colspan="8" %)(((
622 +|(% colspan="8" style="text-align:center; vertical-align:middle" %)(((
631 631  Set the time for switching from the first position loop (P02-01) to the second position loop (P02-04) in the position control mode.
632 632  
633 -|(% style="text-align:center; vertical-align:middle" %)[[image:image-20230515140953-12.png]]|
625 +[[image:image-20230515140953-12.png]]|
634 634  
635 635  If P02-04≤P02-01, then P02-16 is invalid, and the second gain is switched from the first gain immediately.
636 636  )))
... ... @@ -1186,3 +1186,13 @@
1186 1186  
1187 1187  Table 7-11 Notch filter function code parameters
1188 1188  ~)~)~)
1181 +
1182 +**Low frequency vibration suppression**
1183 +
1184 +Low-frequency vibration suppression is suitable for working conditions where the motor vibrates during deceleration and shutdown after the position command is sent, and the vibration amplitude gradually decreases. The use of the low-frequency vibration suppression function is effective in reducing the time to complete positioning due to vibration effects.
1185 +
1186 +(% style="text-align:center" %)
1187 +(((
1188 +(% class="wikigeneratedid img-thumbnail" style="display:inline-block" %)
1189 +[[**Figure 7-13 Applicable working conditions for low-frequency vibration suppression**>>image:20230516-0713.png||id="20230516-0713.png"]]
1190 +)))
20230516-0713.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Karen
Size
... ... @@ -1,0 +1,1 @@
1 +8.4 KB
Content