Changes for page 07 Adjustments
Last modified by Iris on 2025/07/24 11:03
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -593,36 +593,43 @@ 593 593 594 594 |=(% rowspan="2" style="text-align:center; vertical-align:middle; width:120px" %)**P02-13**|=(% style="width:150px" %)Parameter name|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Setting method**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Effective time**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Default**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Set range**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Application category**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Unit** 595 595 |(% style="text-align:center; width:150px" %)Delay Time for Gain Switching|(% style="text-align:center" %)Operation setting|(% style="text-align:center" %)Effective immediately|(% style="text-align:center" %)20|(% style="text-align:center" %)0 to 10000|(% style="text-align:center" %)Gain control|(% style="text-align:center" %)0.1ms 596 -|(% colspan="8" style="text-align:center; vertical-align:middle"%)(((596 +|(% colspan="8" %)((( 597 597 The duration of the switching condition required for the second gain to switch back to the first gain. 598 598 599 -[[image:image-20230515140953-9.png]] 600 - 599 +(% style="text-align:center;vertical-align:middle" %)[[image:image-20230515140953-9.png]] 601 601 **✎**Note: This parameter is only valid when the second gain is switched back to the first gain. 602 602 ))) 603 603 604 604 |=(% rowspan="2" style="text-align:center; vertical-align:middle; width:120px" %)**P02-14**|=(% style="width:150px" %)Parameter name|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Setting method**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Effective time**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Default**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Set range**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Application category**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Unit** 605 605 |(% style="text-align:center; width:150px" %)Gain switching grade|(% style="text-align:center" %)Operation setting|(% style="text-align:center" %)Effective immediately|(% style="text-align:center" %)50|(% style="text-align:center" %)0 to 20000|(% style="text-align:center" %)Gain control|(% style="text-align:center" %)According to the switching conditions 606 -|(% colspan="8" style="text-align:center; vertical-align:middle"%)(((605 +|(% colspan="8" %)((( 607 607 Set the grade of the gain condition. The generation of the actual switching action is affected by the two conditions of grade and hysteresis. 608 608 609 -[[image:image-20230515140953-10.png]] 608 +(% style="text-align:center" %) 609 +((( 610 +(% class="wikigeneratedid img-thumbnail" style="display:inline-block" %) 611 +[[image:image-20230515140953-10.png||id="image-20230515140953-10.png"]] 610 610 ))) 613 +))) 611 611 612 612 |=(% rowspan="2" style="text-align:center; vertical-align:middle; width:120px" %)**P02-15**|=(% style="width:150px" %)Parameter name|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Setting method**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Effective time**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Default**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Set range**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Application category**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Unit** 613 613 |(% style="text-align:center; width:150px" %)Gain switching hysteresis|(% style="text-align:center" %)Operation setting|(% style="text-align:center" %)Effective immediately|(% style="text-align:center" %)20|(% style="text-align:center" %)0 to 20000|(% style="text-align:center" %)Gain control|(% style="text-align:center" %)According to the switching conditions 614 -|(% colspan="8" style="text-align:center; vertical-align:middle"%)(((617 +|(% colspan="8" %)((( 615 615 Set the hysteresis to meet the gain switching condition. 616 616 617 -[[image:image-20230515140953-11.png]] 620 +(% style="text-align:center" %) 621 +((( 622 +(% class="wikigeneratedid img-thumbnail" style="display:inline-block" %) 623 +[[image:image-20230515140953-11.png||id="image-20230515140953-11.png"]] 618 618 ))) 625 +))) 619 619 620 620 |=(% rowspan="2" style="text-align:center; vertical-align:middle; width:120px" %)**P02-16**|=(% style="width:150px" %)Parameter name|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Setting method**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Effective time**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Default**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Set range**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Application category**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Unit** 621 621 |(% style="text-align:center; width:150px" %)Position loop gain switching time|(% style="text-align:center" %)Operation setting|(% style="text-align:center" %)Effective immediately|(% style="text-align:center" %)30|(% style="text-align:center" %)0 to 10000|(% style="text-align:center" %)Gain control|(% style="text-align:center" %)0.1ms 622 -|(% colspan="8" style="text-align:center; vertical-align:middle"%)(((629 +|(% colspan="8" %)((( 623 623 Set the time for switching from the first position loop (P02-01) to the second position loop (P02-04) in the position control mode. 624 624 625 -[[image:image-20230515140953-12.png]]| 632 +|(% style="text-align:center; vertical-align:middle" %)[[image:image-20230515140953-12.png]]| 626 626 627 627 If P02-04≤P02-01, then P02-16 is invalid, and the second gain is switched from the first gain immediately. 628 628 )))