Changes for page 07 Adjustments
Last modified by Iris on 2025/07/24 11:03
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Content
-
... ... @@ -593,36 +593,43 @@ 593 593 594 594 |=(% rowspan="2" style="text-align:center; vertical-align:middle; width:120px" %)**P02-13**|=(% style="width:150px" %)Parameter name|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Setting method**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Effective time**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Default**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Set range**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Application category**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Unit** 595 595 |(% style="text-align:center; width:150px" %)Delay Time for Gain Switching|(% style="text-align:center" %)Operation setting|(% style="text-align:center" %)Effective immediately|(% style="text-align:center" %)20|(% style="text-align:center" %)0 to 10000|(% style="text-align:center" %)Gain control|(% style="text-align:center" %)0.1ms 596 -|(% colspan=" 8"style="text-align:center; vertical-align:middle"%)(((596 +|(% colspan="6" %)((( 597 597 The duration of the switching condition required for the second gain to switch back to the first gain. 598 598 599 -[[image:image-20230515140953-9.png]] 600 - 599 +(% style="text-align:center;vertical-align:middle" %)[[image:image-20230515140953-9.png]] 601 601 **✎**Note: This parameter is only valid when the second gain is switched back to the first gain. 602 602 ))) 603 603 604 604 |=(% rowspan="2" style="text-align:center; vertical-align:middle; width:120px" %)**P02-14**|=(% style="width:150px" %)Parameter name|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Setting method**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Effective time**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Default**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Set range**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Application category**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Unit** 605 605 |(% style="text-align:center; width:150px" %)Gain switching grade|(% style="text-align:center" %)Operation setting|(% style="text-align:center" %)Effective immediately|(% style="text-align:center" %)50|(% style="text-align:center" %)0 to 20000|(% style="text-align:center" %)Gain control|(% style="text-align:center" %)According to the switching conditions 606 -|(% colspan="8" style="text-align:center; vertical-align:middle"%)(((605 +|(% colspan="8" %)((( 607 607 Set the grade of the gain condition. The generation of the actual switching action is affected by the two conditions of grade and hysteresis. 608 608 609 -[[image:image-20230515140953-10.png]] 608 +(% style="text-align:center" %) 609 +((( 610 +(% class="wikigeneratedid img-thumbnail" style="display:inline-block" %) 611 +[[image:image-20230515140953-10.png||id="image-20230515140953-10.png"]] 610 610 ))) 613 +))) 611 611 612 612 |=(% rowspan="2" style="text-align:center; vertical-align:middle; width:120px" %)**P02-15**|=(% style="width:150px" %)Parameter name|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Setting method**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Effective time**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Default**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Set range**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Application category**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Unit** 613 613 |(% style="text-align:center; width:150px" %)Gain switching hysteresis|(% style="text-align:center" %)Operation setting|(% style="text-align:center" %)Effective immediately|(% style="text-align:center" %)20|(% style="text-align:center" %)0 to 20000|(% style="text-align:center" %)Gain control|(% style="text-align:center" %)According to the switching conditions 614 -|(% colspan="8" style="text-align:center; vertical-align:middle"%)(((617 +|(% colspan="8" %)((( 615 615 Set the hysteresis to meet the gain switching condition. 616 616 617 -[[image:image-20230515140953-11.png]] 620 +(% style="text-align:center" %) 621 +((( 622 +(% class="wikigeneratedid img-thumbnail" style="display:inline-block" %) 623 +[[image:image-20230515140953-11.png||id="image-20230515140953-11.png"]] 618 618 ))) 625 +))) 619 619 620 620 |=(% rowspan="2" style="text-align:center; vertical-align:middle; width:120px" %)**P02-16**|=(% style="width:150px" %)Parameter name|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Setting method**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Effective time**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Default**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Set range**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Application category**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Unit** 621 621 |(% style="text-align:center; width:150px" %)Position loop gain switching time|(% style="text-align:center" %)Operation setting|(% style="text-align:center" %)Effective immediately|(% style="text-align:center" %)30|(% style="text-align:center" %)0 to 10000|(% style="text-align:center" %)Gain control|(% style="text-align:center" %)0.1ms 622 -|(% colspan="8" style="text-align:center; vertical-align:middle"%)(((629 +|(% colspan="8" %)((( 623 623 Set the time for switching from the first position loop (P02-01) to the second position loop (P02-04) in the position control mode. 624 624 625 -[[image:image-20230515140953-12.png]]| 632 +|(% style="text-align:center; vertical-align:middle" %)[[image:image-20230515140953-12.png]]| 626 626 627 627 If P02-04≤P02-01, then P02-16 is invalid, and the second gain is switched from the first gain immediately. 628 628 ))) ... ... @@ -1178,13 +1178,3 @@ 1178 1178 1179 1179 Table 7-11 Notch filter function code parameters 1180 1180 ~)~)~) 1181 - 1182 -**Low frequency vibration suppression** 1183 - 1184 -Low-frequency vibration suppression is suitable for working conditions where the motor vibrates during deceleration and shutdown after the position command is sent, and the vibration amplitude gradually decreases. The use of the low-frequency vibration suppression function is effective in reducing the time to complete positioning due to vibration effects. 1185 - 1186 -(% style="text-align:center" %) 1187 -((( 1188 -(% class="wikigeneratedid img-thumbnail" style="display:inline-block" %) 1189 -[[**Figure 7-13 Applicable working conditions for low-frequency vibration suppression**>>image:20230516-0713.png||id="20230516-0713.png"]] 1190 -)))
- 20230516-0713.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Karen - Size
-
... ... @@ -1,1 +1,0 @@ 1 -8.4 KB - Content