Changes for page 07 Adjustments
Last modified by Iris on 2025/07/24 11:03
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1198,3 +1198,13 @@ 1198 1198 (% class="wikigeneratedid img-thumbnail" style="display:inline-block" %) 1199 1199 [[**Figure 7-14 Applicable situations for type A vibration suppression**>>image:20230516-0714.png||id="20230516-0714.png"]] 1200 1200 ))) 1201 + 1202 +== Type A vibration suppression == 1203 + 1204 +Type A vibration suppression is suitable for durational vibration during motor operation or shutdown. Use Type A suppression to help reduce vibrations at specific frequencies that occur during motion (For the situation where the vibration continues to maintain and the vibration amplitude is almost constant after the command is completed.) As shown in [[Figure 7-14>>path:#F714]]. 1205 + 1206 +(% style="text-align:center" %) 1207 +((( 1208 +(% class="wikigeneratedid img-thumbnail" style="display:inline-block" %) 1209 +[[**Figure 7-14 Applicable situations for type A vibration suppression**>>image:20230516-0714.png||id="20230516-0714.png"]] 1210 +)))