627 627  If P02-04≤P02-01, then P02-16 is invalid, and the second gain is switched from the first gain immediately.
628 628  )))
629 629  
630 -== **Gain switching** ==
631 -
632 -Gain switching function:
633 -
634 -●Switch to a lower gain in the motor stationary (servo enabled)state to suppress vibration;
635 -
636 -●Switch to a higher gain in the motor stationary state to shorten the positioning time;
637 -
638 -●Switch to a higher gain in the motor running state to get better command tracking performance;
639 -
640 -●Switch different gain settings by external signals depending on the load connected.
641 -
642 -(1) Gain switching parameter setting
643 -
644 -①When P02-07=0
645 -
646 -Fixed use of the first gain (using P02-01~~P02-03), and the switching of P/PI (proportional/proportional integral) control could be realized through DI function 10 (GAIN-SEL, gain switching).
647 -
648 -(% style="text-align:center" %)
649 -[[image:20230515-8.png]]
650 -
651 -② When P02-07=1
652 -
653 -The switching conditions can be set through parameter P02-08 to realize switching between the first gain (P02-01~~P02-03) and the second gain (P02-04~~P02-06).
654 -
655 -(% style="text-align:center" %)
656 -[[image:20230515-9.png]]
657 -
658 -Figure 7-9 Flow chart of gain switching when P02-07=1
659 -
660 -|(% style="width:72px" %)**P02-08**|(% style="width:146px" %)**Content**|**Diagram**
661 -|(% style="width:72px" %)0|(% style="width:146px" %)Fixed use of the first gain|~-~-
662 -|(% style="width:72px" %)1|(% style="width:146px" %)Switching with DI|~-~-
663 -|(% style="width:72px" %)(((
664 -
665 -
666 -
667 -
668 -
669 -
670 -2
671 -)))|(% style="width:146px" %)(((
672 -
673 -
674 -
675 -
676 -
677 -
678 -Large torque command
679 -)))|[[image:image-20230515140641-1.png]]
680 -|(% style="width:72px" %)(((
681 -
682 -
683 -
684 -
685 -
686 -
687 -
688 -3
689 -)))|(% style="width:146px" %)Large actual torque|[[image:image-20230515140641-2.png]]
690 -|(% style="width:72px" %)(((
691 -
692 -
693 -
694 -
695 -
696 -
697 -4
698 -)))|(% style="width:146px" %)(((
699 -
700 -
701 -
702 -
703 -
704 -
705 -Large speed command
706 -)))|[[image:image-20230515140641-3.png]]
707 -
708 -|(% style="width:74px" %)**P02-08**|(% style="width:176px" %)**Content**|**Diagram**
709 -|(% style="width:74px" %)(((
710 -
711 -
712 -
713 -
714 -
715 -5
716 -)))|(% style="width:176px" %)(((
717 -
718 -
719 -
720 -
721 -
722 -Fast actual speed
723 -)))|(((
724 -
725 -
726 -[[image:image-20230515140641-4.png]]
727 -)))
728 -|(% style="width:74px" %)(((
729 -
730 -
731 -
732 -
733 -
734 -
735 -
736 -6
737 -)))|(% style="width:176px" %)(((
738 -
739 -
740 -
741 -
742 -
743 -
744 -
745 -Speed command change rate is large
746 -)))|[[image:image-20230515140641-5.png]]
747 -|(% style="width:74px" %)(((
748 -
749 -
750 -
751 -
752 -
753 -
754 -7
755 -
756 -
757 -)))|(% style="width:176px" %)(((
758 -
759 -
760 -
761 -
762 -
763 -
764 -Large position deviation
765 -)))|[[image:image-20230515140641-6.png]]
766 -|(% style="width:74px" %)(((
767 -
768 -
769 -
770 -
771 -
772 -8
773 -)))|(% style="width:176px" %)(((
774 -
775 -
776 -
777 -
778 -
779 -Position command
780 -)))|[[image:image-20230515140641-7.png]]
781 -
782 -|(% style="width:73px" %)(((
783 -
784 -
785 -
786 -
787 -
788 -
789 -9
790 -)))|(% style="width:154px" %)(((
791 -
792 -
793 -
794 -
795 -
796 -
797 -Positioning completed
798 -)))|[[image:image-20230515140641-8.png]]
799 -|(% style="width:73px" %)(((
800 -
801 -
802 -10
803 -
804 -
805 -)))|(% style="width:154px" %)(((
806 -
807 -
808 -Position command + actual speed
809 -)))|(((
810 -
811 -
812 -Refer to the chart below
813 -)))
814 -
815 -(% style="text-align:center" %)
816 -[[image:20230515-10.png]]
817 -
818 -Figure 7-10 P02-08=10 Position command + actual speed gain description
819 -
820 -(2) Description of related parameters
821 -
822 -|(% rowspan="2" style="width:68px" %)
823 -**P02-07**|(% style="width:150px" %)**Parameter name**|**Setting method**|**Effective time**|**Default**|**Set range**|**Application category**|**Unit**
824 -|(% style="width:150px" %)The second gain switching mode|Operation setting|Effective immediately|0|0 to 1|Gain control|
825 -|(% colspan="8" %)(((
826 -Set the switching mode of the second gain.
827 -
828 -|**Setting value**|**Function**
829 -|0|(((
830 -The first gain is used by default. Switching using DI function 10 (GAIN-SEL, gain switching):
831 -
832 -DI logic invalid: PI control;
833 -
834 -DI logic valid: PI control.
835 -)))
836 -|1|The first gain and the second gain are switched by the setting value of P02-08.
837 -)))
838 -
839 -|(% rowspan="2" %)
840 -**P02-08**|**Parameter name**|**Setting method**|**Effective time**|**Default**|**Set range**|**Application category**|**Unit**
841 -|Gain switching condition selection|Operation setting|Effective immediately|0|0 to 10|Gain control|
842 -|(% colspan="8" %)(((
843 -Set the conditions for gain switching.
844 -
845 -|Setting value|Gain switching conditions|Details
846 -|0|The default is the first gain|Fixed use of the first gain
847 -|1|Switch by DI port|(((
848 -Use DI function 10 (GAIN-SEL, gain switching);
849 -
850 -DI logic is invalid: the first gain (P02-01~~P02-03);
851 -
852 -DI logic is valid: the second gain (P02-04~~P02-06).
853 -)))
854 -|2|Large torque command|(((
855 -In the previous first gain, when the absolute value of torque command is greater than (grade + hysteresis), the second gain is switched;
856 -
857 -In the previous second gain, when the absolute value of torque command is less than the value of (grade - hysteresis) and the duration is greater than [P02-13], the first gain is returned.
858 -
859 -
860 -)))
861 -|3|Large actual torque|(((
862 -In the previous first gain, when the absolute value of actual torque is greater than ( grade + hysteresis ), the second gain is switched;
863 -
864 -In the previous second gain, when the absolute value of actual torque is less than the value of (grade - hysteresis) and the duration is greater than [P02-13], the first gain is returned .
865 -
866 -
867 -)))
868 -|4|Large speed command|(((
869 -In the previous first gain, when the absolute value of speed command is greater than (grade + hysteresis), the second gain is switched;
870 -
871 -In the previous second gain, when the absolute value of speed command is less than the value of (grade - hysteresis) and the duration is greater than [P02-13], the first gain is returned .
872 -
873 -
874 -)))
875 -|5|Large actual speed|(((
876 -In the previous first gain, when the absolute value of actual speed is greater than (grade + hysteresis), the second gain is switched;
877 -
878 -In the previous second gain, when the absolute value of actual speed is less than the value of (grade - hysteresis) and the duration is greater than [P02-13], the first gain is returned .
879 -
880 -
881 -)))
882 -|(((
883 -
884 -
885 -6
886 -)))|(((
887 -
888 -
889 -Large rate of change in speed command
890 -)))|(((
891 -In the previous first gain, when the absolute value of the rate of change in speed command is greater than (grade + hysteresis), the second gain is switched;
892 -
893 -In the previous second gain, switch to the first gain when the absolute value of the rate of change in speed command is less than the value of (grade - hysteresis) and the duration is greater than [P02-13], the first gain is returned .
894 -
895 -
896 -)))
897 -|(((
898 -
899 -
900 -7
901 -)))|(((
902 -
903 -
904 -Large position deviation
905 -)))|(((
906 -In the previous first gain, when the absolute value of position deviation is greater than (grade + hysteresis), the second gain is switched;
907 -
908 -In the previous second gain, switch to the first gain when the absolute value of position deviation is less than the value of (grade - hysteresis) and the duration is greater than [P02-13], the first gain is returned .
909 -)))
910 -|8|Position command|(((
911 -In the previous first gain, if the position command is not 0, switch to the second gain;
912 -
913 -In the previous second gain, if the position command is 0 and the duration is greater than [P02-13], the first gain is returned.
914 -)))
915 -|(((
916 -
917 -
918 -9
919 -)))|(((
920 -
921 -
922 -Positioning complete
923 -)))|(((
924 -In the previous first gain, if the positioning is not completed, the second gain is switched; In the previous second gain, if the positioning is not completed and the duration is greater than [P02-13], the first gain is returned.
925 -
926 -
927 -)))
928 -|(((
929 -
930 -
931 -10
932 -)))|(((
933 -
934 -
935 -Position command + actual speed
936 -)))|(((
937 -In the previous first gain, if the position command is not 0, the second gain is switched;
938 -
939 -In the previous second gain, if the position command is 0, the duration is greater than [P02-13] and the absolute value of actual speed is less than ( grade - hysteresis).
940 -
941 -
942 -)))
943 -
944 -
945 -)))
946 -
947 -|(% rowspan="2" %)
948 -**P02-13**|**Parameter name**|**Setting method**|**Effective time**|**Default**|**Set range**|**Application category**|**Unit**
949 -|Delay Time for Gain Switching|Operation setting|Effective immediately|20|0 to 10000|Gain control|0.1ms
950 -|(% colspan="8" %)(((
951 -The duration of the switching condition required for the second gain to switch back to the first gain.
952 -
953 -[[image:image-20230515140953-9.png]]
954 -
955 -**✎**Note: This parameter is only valid when the second gain is switched back to the first gain.
956 -)))
957 -
958 -|(% rowspan="2" %)
959 -**P02-14**|**Parameter name**|**Setting method**|**Effective time**|**Default**|**Set range**|**Application category**|**Unit**
960 -|Gain switching grade|Operation setting|Effective immediately|50|0 to 20000|Gain control|According to the switching conditions
961 -|(% colspan="8" %)(((
962 -Set the grade of the gain condition. The generation of the actual switching action is affected by the two conditions of grade and hysteresis.
963 -
964 -[[image:image-20230515140953-10.png]]
965 -)))
966 -
967 -|(% rowspan="2" %)
968 -**P02-15**|**Parameter name**|**Setting method**|**Effective time**|**Default**|**Set range**|**Application category**|**Unit**
969 -|Gain switching hysteresis|Operation setting|Effective immediately|20|0 to 20000|Gain control|According to the switching conditions
970 -|(% colspan="8" %)(((
971 -Set the hysteresis to meet the gain switching condition.
972 -
973 -[[image:image-20230515140953-11.png]]
974 -)))
975 -
976 -|(% rowspan="2" %)
977 -**P02-16**|**Parameter name**|**Setting method**|**Effective time**|**Default**|**Set range**|**Application category**|**Unit**
978 -|Position loop gain switching time|Operation setting|Effective immediately|30|0 to 10000|Gain control|0.1ms
979 -|(% colspan="8" %)(((
980 -Set the time for switching from the first position loop (P02-01) to the second position loop (P02-04) in the position control mode.
981 -
982 -[[image:image-20230515140953-12.png]]
983 -
984 -If P02-04≤P02-01, then P02-16 is invalid, and the second gain is switched from the first gain immediately.
985 -)))
986 -
987 987  = **Mechanical resonance suppression** =
988 988  
989 989  == Mechanical resonance suppression methods ==
... ... @@ -1100,46 +1100,34 @@
1100 1100  [[**Figure 7-13 Applicable working conditions for low-frequency vibration suppression**>>image:20230516-0713.png||id="20230516-0713.png"]]
1101 1101  )))
1102 1102  
1103 -|=(% scope="row" style="text-align: center; vertical-align: middle; width: 120px;" %)**Function code**|=(% style="text-align: center; vertical-align: middle; width: 250px;" %)**Name**|=(% style="text-align:center; vertical-align:middle; width:150px" %)(((
746 +|=(% scope="row" style="text-align: center; vertical-align: middle; width: 120px;" %)**Function code**|=(% style="text-align: center; vertical-align: middle; width: 155px;" %)**Name**|=(% style="text-align: center; vertical-align: middle; width: 137px;" %)(((
1104 1104  **Setting method**
1105 -)))|=(% style="text-align:center; vertical-align:middle; width:128px" %)(((
1106 -**Effective time**
1107 -)))|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Default value**|=(% style="text-align: center; vertical-align: middle; width: 107px;" %)**Range**|=(% style="text-align: center; vertical-align: middle; width: 350px;" %)**Definition**|=(% style="text-align: center; vertical-align: middle;" %)**Unit**
1108 -|P4-11|Enable low-frequency vibration suppression function|(((
1109 -Operation
748 +)))|=(% style="text-align: center; vertical-align: middle; width: 115px;" %)(((
749 +**Effective time**
750 +)))|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Default value**|=(% style="text-align: center; vertical-align: middle; width: 100px;" %)**Range**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Definition**|=(% style="text-align: center; vertical-align: middle; width: 96px;" %)**Unit**
751 +|=(% style="text-align:center; vertical-align:middle" %)P4-11|(% style="width:294px" %)Enable low-frequency vibration suppression function|(% style="text-align:center; vertical-align:middle; width:137px" %)(((
752 +Operation setting
753 +)))|(% style="text-align:center; vertical-align:middle; width:156px" %)(((
754 +Effective immediately
755 +)))|(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle; width:126px" %)0 to 1|(% style="width:448px" %)When the function code is set to 1, enable the low-frequency vibration suppression function.|(% style="width:96px" %)
756 +|=(% style="text-align:center; vertical-align:middle" %)P4-12|(% style="width:294px" %)Low-frequency vibration suppression frequency|(% style="text-align:center; vertical-align:middle; width:137px" %)(((
757 +Operation setting
758 +)))|(% style="text-align:center; vertical-align:middle; width:156px" %)(((
759 +Effective immediately
760 +)))|(% style="text-align:center; vertical-align:middle" %)800|(% style="text-align:center; vertical-align:middle; width:126px" %)10 to 2000|(% style="width:448px" %)Set the vibration frequency when vibration occurs at the load end.|(% style="text-align:center; vertical-align:middle; width:96px" %)0.1HZ
761 +|=(% style="text-align:center; vertical-align:middle" %)P4-14|(% style="width:294px" %)Shutdown vibration detection amplitude|(% style="text-align:center; vertical-align:middle; width:137px" %)(((
762 +Operation setting
763 +)))|(% style="text-align:center; vertical-align:middle; width:156px" %)(((
764 +Effective immediately
765 +)))|(% style="text-align:center; vertical-align:middle" %)100|(% style="text-align:center; vertical-align:middle; width:126px" %)0 to 1000|(% style="width:448px" %)When the vibration amplitude is greater than (P5-12*P4-14 detection amplitude ratio), the low-frequency vibration frequency can be recognized and updated to the U0-16 monitor quantity.|(% style="text-align:center; vertical-align:middle; width:96px" %)0.001
1110 1110  
1111 -setting
1112 -)))|(((
1113 -Effective
767 +**Vibration frequency detection:**
1114 1114  
1115 -immediately
1116 -)))|0|0 to 1|When the function code is set to 1, enable the low-frequency vibration suppression function.|
1117 -|P4-12|Low-frequency vibration suppression frequency|(((
1118 -Operation
1119 -
1120 -setting
1121 -)))|(((
1122 -Effective
1123 -
1124 -immediately
1125 -)))|800|10 to 2000|Set the vibration frequency when vibration occurs at the load end.|0.1HZ
1126 -|P4-14|Shutdown vibration detection amplitude|(((
1127 -Operation
1128 -
1129 -setting
1130 -)))|(((
1131 -Effective
1132 -
1133 -immediately
1134 -)))|100|0 to 1000|When the vibration amplitude is greater than (P5-12*P4-14 detection amplitude ratio), the low-frequency vibration frequency can be recognized and updated to the U0-16 monitor quantity.|0.001
1135 -
1136 -**(1) Vibration frequency detection:**
1137 -
1138 1138  * Users can measure vibration by measuring equipment such as laser displacement.
1139 1139  * If no measuring equipment, the user can also read the position deviation waveform to confirm the vibration frequency through the "waveform" function of the PC debugging software.
1140 1140  * Low-frequency vibration detection needs to be coordinated by the two parameters of completion positioning threshold and vibration detection amplitude. When the vibration amplitude is greater than (P5-12*P4-14 detection amplitude ratio), the low-frequency vibration frequency can be recognized and updated to U0-16 monitoring quantity. For example, when the vibration amplitude is greater than (P5-12*P4-14*0.001) detection amplitude ratio. For example, in P05-12=800, P04_14=50, the vibration amplitude is greater than P5-12*P4-14*0.001=800*50*0.001=40 pulses, stop vibration frequency can be identified in U0-16.
1141 1141  
1142 -**(2) Debugging method:**
773 +**Debugging method:**
1143 1143  
1144 1144  * Set the appropriate positioning completion thresholds P5-12 and P4-14 to help the software detect the vibration frequency.
1145 1145  * Run the position curve command to obtain the vibration frequency, and obtain the frequency through the speed curve of oscilloscope or U0-16.
... ... @@ -1146,8 +1146,9 @@
1146 1146  * Set P4-12 vibration frequency and enable low frequency vibration suppression function P4-11.
1147 1147  * Run again to observe the speed waveform and determine whether to eliminate the vibration. If the vibration is not eliminated, please manually modify the vibration frequency and try again.
1148 1148  
1149 -|[[image:image-20230516105941-2.png]]
1150 -|Note: If there is a speed substantial vibration and the vibration increases during the debugging, it may be that the low-frequency vibration suppression is not suitable for the current working conditions, please immediately close the servo, or power down!
780 +(% class="table-bordered" style="margin-right:auto" %)
781 +(% class="warning" %)|(% style="text-align:center; vertical-align:middle" %)[[image:image-20230516105941-2.png]]
782 +|(% style="text-align:left; vertical-align:middle" %)Note: If there is a speed substantial vibration and the vibration increases during the debugging, it may be that the low-frequency vibration suppression is not suitable for the current working conditions, please immediately close the servo, or power down!
1151 1151  