Changes for page 07 Adjustments
Last modified by Iris on 2025/07/24 11:03
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -743,34 +743,34 @@ 743 743 [[**Figure 7-13 Applicable working conditions for low-frequency vibration suppression**>>image:20230516-0713.png||id="20230516-0713.png"]] 744 744 ))) 745 745 746 -|=(% scope="row" style="text-align: center; vertical-align: middle; width: 120px;" %)**Function code**|=(% style="text-align: center; vertical-align: middle; width: 294px;" %)**Name**|=(% style="text-align: center; vertical-align: middle; width: 137px;" %)(((746 +|=(% scope="row" style="text-align: center; vertical-align: middle; width: 120px;" %)**Function code**|=(% style="text-align: center; vertical-align: middle; width: 155px;" %)**Name**|=(% style="text-align: center; vertical-align: middle; width: 137px;" %)((( 747 747 **Setting method** 748 -)))|=(% style="text-align: center; vertical-align: middle; width: 15 6px;" %)(((748 +)))|=(% style="text-align: center; vertical-align: middle; width: 115px;" %)((( 749 749 **Effective time** 750 -)))|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Default value**|=(% style="text-align: center; vertical-align: middle; width: 1 26px;" %)**Range**|=(% style="text-align: center; vertical-align: middle; width:448px;" %)**Definition**|=(% style="text-align: center; vertical-align: middle; width: 96px;" %)**Unit**750 +)))|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Default value**|=(% style="text-align: center; vertical-align: middle; width: 100px;" %)**Range**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Definition**|=(% style="text-align: center; vertical-align: middle; width: 96px;" %)**Unit** 751 751 |=(% style="text-align:center; vertical-align:middle" %)P4-11|(% style="width:294px" %)Enable low-frequency vibration suppression function|(% style="text-align:center; vertical-align:middle; width:137px" %)((( 752 752 Operation setting 753 753 )))|(% style="text-align:center; vertical-align:middle; width:156px" %)((( 754 754 Effective immediately 755 -)))|(% style="text-align:center; vertical-align:middle 755 +)))|(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle; width:126px" %)0 to 1|(% style="width:448px" %)When the function code is set to 1, enable the low-frequency vibration suppression function.|(% style="width:96px" %) 756 756 |=(% style="text-align:center; vertical-align:middle" %)P4-12|(% style="width:294px" %)Low-frequency vibration suppression frequency|(% style="text-align:center; vertical-align:middle; width:137px" %)((( 757 757 Operation setting 758 758 )))|(% style="text-align:center; vertical-align:middle; width:156px" %)((( 759 759 Effective immediately 760 760 )))|(% style="text-align:center; vertical-align:middle" %)800|(% style="text-align:center; vertical-align:middle; width:126px" %)10 to 2000|(% style="width:448px" %)Set the vibration frequency when vibration occurs at the load end.|(% style="text-align:center; vertical-align:middle; width:96px" %)0.1HZ 761 -|=(% style="text-align:center; vertical-align:middle" %)P4-14|(% style="width:294px" %)Shutdown vibration detection amplitude|(% style="width:137px" %)((( 761 +|=(% style="text-align:center; vertical-align:middle" %)P4-14|(% style="width:294px" %)Shutdown vibration detection amplitude|(% style="text-align:center; vertical-align:middle; width:137px" %)((( 762 762 Operation setting 763 -)))|(% style="width:156px" %)((( 763 +)))|(% style="text-align:center; vertical-align:middle; width:156px" %)((( 764 764 Effective immediately 765 765 )))|(% style="text-align:center; vertical-align:middle" %)100|(% style="text-align:center; vertical-align:middle; width:126px" %)0 to 1000|(% style="width:448px" %)When the vibration amplitude is greater than (P5-12*P4-14 detection amplitude ratio), the low-frequency vibration frequency can be recognized and updated to the U0-16 monitor quantity.|(% style="text-align:center; vertical-align:middle; width:96px" %)0.001 766 766 767 -** (1)Vibration frequency detection:**767 +**Vibration frequency detection:** 768 768 769 769 * Users can measure vibration by measuring equipment such as laser displacement. 770 770 * If no measuring equipment, the user can also read the position deviation waveform to confirm the vibration frequency through the "waveform" function of the PC debugging software. 771 771 * Low-frequency vibration detection needs to be coordinated by the two parameters of completion positioning threshold and vibration detection amplitude. When the vibration amplitude is greater than (P5-12*P4-14 detection amplitude ratio), the low-frequency vibration frequency can be recognized and updated to U0-16 monitoring quantity. For example, when the vibration amplitude is greater than (P5-12*P4-14*0.001) detection amplitude ratio. For example, in P05-12=800, P04_14=50, the vibration amplitude is greater than P5-12*P4-14*0.001=800*50*0.001=40 pulses, stop vibration frequency can be identified in U0-16. 772 772 773 -** (2)Debugging method:**773 +**Debugging method:** 774 774 775 775 * Set the appropriate positioning completion thresholds P5-12 and P4-14 to help the software detect the vibration frequency. 776 776 * Run the position curve command to obtain the vibration frequency, and obtain the frequency through the speed curve of oscilloscope or U0-16.