Changes for page 07 Adjustments
Last modified by Iris on 2025/07/24 11:03
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -743,39 +743,27 @@ 743 743 [[**Figure 7-13 Applicable working conditions for low-frequency vibration suppression**>>image:20230516-0713.png||id="20230516-0713.png"]] 744 744 ))) 745 745 746 -|=(% scope="row" style="text-align: center; vertical-align: middle; width: 120px;" %)**Function code**|=(% style="text-align: center; vertical-align: middle; width: 2 50px;" %)**Name**|=(% style="text-align:center; vertical-align:middle; width:180px" %)(((746 +|=(% scope="row" style="text-align: center; vertical-align: middle; width: 120px;" %)**Function code**|=(% style="text-align: center; vertical-align: middle; width: 294px;" %)**Name**|=(% style="text-align: center; vertical-align: middle; width: 137px;" %)((( 747 747 **Setting method** 748 -)))|=(% style="text-align:center; vertical-align:middle; width:15 0px" %)(((748 +)))|=(% style="text-align: center; vertical-align: middle; width: 156px;" %)((( 749 749 **Effective time** 750 -)))|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Default value**|=(% style="text-align: center; vertical-align: middle; width: 110px;" %)**Range**|=(% style="text-align: center; vertical-align: middle; width: 400px;" %)**Definition**|=(% style="text-align: center; vertical-align: middle;" %)**Unit** 751 -|P4-11|Enable low-frequency vibration suppression function|((( 752 -Operation 750 +)))|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Default value**|=(% style="text-align: center; vertical-align: middle; width: 126px;" %)**Range**|=(% style="text-align: center; vertical-align: middle; width: 448px;" %)**Definition**|=(% style="text-align: center; vertical-align: middle; width: 96px;" %)**Unit** 751 +|=(% style="text-align:center; vertical-align:middle" %)P4-11|(% style="width:294px" %)Enable low-frequency vibration suppression function|(% style="text-align:center; vertical-align:middle; width:137px" %)((( 752 +Operation setting 753 +)))|(% style="text-align:center; vertical-align:middle;width:156px" %)((( 754 +Effective immediately 755 +)))|0|(% style="text-align:center; vertical-align:middle;width:126px" %)0 to 1|(% style="width:448px" %)When the function code is set to 1, enable the low-frequency vibration suppression function.|(% style="width:96px" %) 756 +|=(% style="text-align:center; vertical-align:middle" %)P4-12|(% style="width:294px" %)Low-frequency vibration suppression frequency|(% style="text-align:center; vertical-align:middle;width:137px" %)((( 757 +Operation setting 758 +)))|(% style="text-align:center; vertical-align:middle;width:156px" %)((( 759 +Effective immediately 760 +)))|800|(% style="text-align:center; vertical-align:middle;width:126px" %)10 to 2000|(% style="width:448px" %)Set the vibration frequency when vibration occurs at the load end.|(% style="text-align:center; vertical-align:middle;width:96px" %)0.1HZ 761 +|=(% style="text-align:center; vertical-align:middle" %)P4-14|(% style="width:294px" %)Shutdown vibration detection amplitude|(% style="width:137px" %)((( 762 +Operation setting 763 +)))|(% style="width:156px" %)((( 764 +Effective immediately 765 +)))|(% style="text-align:center; vertical-align:middle" %)100|(% style="text-align:center; vertical-align:middle;width:126px" %)0 to 1000|(% style="text-align:center; vertical-align:middle;width:448px" %)When the vibration amplitude is greater than (P5-12*P4-14 detection amplitude ratio), the low-frequency vibration frequency can be recognized and updated to the U0-16 monitor quantity.|(% style="text-align:center; vertical-align:middle;width:96px" %)0.001 753 753 754 -setting 755 -)))|((( 756 -Effective 757 - 758 -immediately 759 -)))|0|0 to 1|When the function code is set to 1, enable the low-frequency vibration suppression function.| 760 -|P4-12|Low-frequency vibration suppression frequency|((( 761 -Operation 762 - 763 -setting 764 -)))|((( 765 -Effective 766 - 767 -immediately 768 -)))|800|10 to 2000|Set the vibration frequency when vibration occurs at the load end.|0.1HZ 769 -|P4-14|Shutdown vibration detection amplitude|((( 770 -Operation 771 - 772 -setting 773 -)))|((( 774 -Effective 775 - 776 -immediately 777 -)))|100|0 to 1000|When the vibration amplitude is greater than (P5-12*P4-14 detection amplitude ratio), the low-frequency vibration frequency can be recognized and updated to the U0-16 monitor quantity.|0.001 778 - 779 779 **(1) Vibration frequency detection:** 780 780 781 781 * Users can measure vibration by measuring equipment such as laser displacement.