Changes for page 07 Adjustments
Last modified by Iris on 2025/07/24 11:03
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -743,35 +743,39 @@ 743 743 [[**Figure 7-13 Applicable working conditions for low-frequency vibration suppression**>>image:20230516-0713.png||id="20230516-0713.png"]] 744 744 ))) 745 745 746 -|=(% scope="row" style="text-align: center; vertical-align: middle; width: 120px;" %)**Function code**|=(% style="text-align: center; vertical-align: middle; width: 2 94px;" %)**Name**|=(% style="text-align:72px;" %)(((746 +|=(% scope="row" style="text-align: center; vertical-align: middle; width: 120px;" %)**Function code**|=(% style="text-align: center; vertical-align: middle; width: 250px;" %)**Name**|=(% style="text-align:center; vertical-align:middle; width:150px" %)((( 747 747 **Setting method** 748 -)))|=(% style="text-align: 6px;" %)(((748 +)))|=(% style="text-align:center; vertical-align:middle; width:128px" %)((( 749 749 **Effective time** 750 -)))|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Default value**|=(% style="text-align: center; vertical-align: middle; width: 126px;" %)**Range**|=(% style="text-align: center; vertical-align: middle; width: 448px;" %)**Definition**|=(% style="text-align: center; vertical-align: middle; width: 96px;" %)**Unit** 751 -|=(% style="text-align:center; vertical-align:middle" %)P4-11|(% style="width:294px" %)Enable low-frequency vibration suppression function|(% style="width:172px" %)((( 752 -Operation setting 753 -)))|(% style="width:126px" %)((( 754 -Effective immediately 755 -)))|0|(% style="width:126px" %)0 to 1|(% style="width:448px" %)When the function code is set to 1, enable the low-frequency vibration suppression function.|(% style="width:96px" %) 756 -|P4-12|(% style="width:294px" %)Low-frequency vibration suppression frequency|(% style="width:172px" %)((( 750 +)))|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Default value**|=(% style="text-align: center; vertical-align: middle; width: 107px;" %)**Range**|=(% style="text-align: center; vertical-align: middle; width: 350px;" %)**Definition**|=(% style="text-align: center; vertical-align: middle;" %)**Unit** 751 +|P4-11|Enable low-frequency vibration suppression function|((( 757 757 Operation 758 758 759 759 setting 760 -)))|( % style="width:126px" %)(((755 +)))|((( 761 761 Effective 762 762 763 763 immediately 764 -)))| 800|(%style="width:126px"%)10to2000|(%style="width:448px"%)Set thevibrationfrequencywhenvibrationoccursatthe load end.|(%style="width:96px" %)0.1HZ765 -|P4-1 4|(% style="width:294px" %)Shutdown vibrationdetectionamplitude|(% style="width:172px" %)(((759 +)))|0|0 to 1|When the function code is set to 1, enable the low-frequency vibration suppression function.| 760 +|P4-12|Low-frequency vibration suppression frequency|((( 766 766 Operation 767 767 768 768 setting 769 -)))|( % style="width:126px" %)(((764 +)))|((( 770 770 Effective 771 771 772 772 immediately 773 -)))|100|(% style="width:126px" %)0 to 1000|(% style="width:448px" %)When the vibration amplitude is greater than (P5-12*P4-14 detection amplitude ratio), the low-frequency vibration frequency can be recognized and updated to the U0-16 monitor quantity.|(% style="width:96px" %)0.001 768 +)))|800|10 to 2000|Set the vibration frequency when vibration occurs at the load end.|0.1HZ 769 +|P4-14|Shutdown vibration detection amplitude|((( 770 +Operation 774 774 772 +setting 773 +)))|((( 774 +Effective 775 + 776 +immediately 777 +)))|100|0 to 1000|When the vibration amplitude is greater than (P5-12*P4-14 detection amplitude ratio), the low-frequency vibration frequency can be recognized and updated to the U0-16 monitor quantity.|0.001 778 + 775 775 **(1) Vibration frequency detection:** 776 776 777 777 * Users can measure vibration by measuring equipment such as laser displacement.