Changes for page 07 Adjustments

Last modified by Iris on 2025/07/24 11:03

From version 55.7
edited by Karen
on 2023/05/16 11:34
Change comment: There is no comment for this version
To version 55.5
edited by Karen
on 2023/05/16 11:31
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -743,27 +743,39 @@
743 743  [[**Figure 7-13 Applicable working conditions for low-frequency vibration suppression**>>image:20230516-0713.png||id="20230516-0713.png"]]
744 744  )))
745 745  
746 -|=(% scope="row" style="text-align: center; vertical-align: middle; width: 120px;" %)**Function code**|=(% style="text-align: center; vertical-align: middle; width: 294px;" %)**Name**|=(% style="text-align: center; vertical-align: middle; width: 137px;" %)(((
746 +|=(% scope="row" style="text-align: center; vertical-align: middle; width: 120px;" %)**Function code**|=(% style="text-align: center; vertical-align: middle; width: 250px;" %)**Name**|=(% style="text-align:center; vertical-align:middle; width:180px" %)(((
747 747  **Setting method**
748 -)))|=(% style="text-align: center; vertical-align: middle; width: 156px;" %)(((
748 +)))|=(% style="text-align:center; vertical-align:middle; width:150px" %)(((
749 749  **Effective time**
750 -)))|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Default value**|=(% style="text-align: center; vertical-align: middle; width: 126px;" %)**Range**|=(% style="text-align: center; vertical-align: middle; width: 448px;" %)**Definition**|=(% style="text-align: center; vertical-align: middle; width: 96px;" %)**Unit**
751 -|=(% style="text-align:center; vertical-align:middle" %)P4-11|(% style="width:294px" %)Enable low-frequency vibration suppression function|(% style="width:137px" %)(((
752 -Operation setting
753 -)))|(% style="width:156px" %)(((
754 -Effective immediately
755 -)))|0|(% style="width:126px" %)0 to 1|(% style="width:448px" %)When the function code is set to 1, enable the low-frequency vibration suppression function.|(% style="width:96px" %)
756 -|P4-12|(% style="width:294px" %)Low-frequency vibration suppression frequency|(% style="width:137px" %)(((
757 -Operation setting
758 -)))|(% style="width:156px" %)(((
759 -Effective immediately
760 -)))|800|(% style="width:126px" %)10 to 2000|(% style="width:448px" %)Set the vibration frequency when vibration occurs at the load end.|(% style="width:96px" %)0.1HZ
761 -|P4-14|(% style="width:294px" %)Shutdown vibration detection amplitude|(% style="width:137px" %)(((
762 -Operation setting
763 -)))|(% style="width:156px" %)(((
764 -Effective immediately
765 -)))|100|(% style="width:126px" %)0 to 1000|(% style="width:448px" %)When the vibration amplitude is greater than (P5-12*P4-14 detection amplitude ratio), the low-frequency vibration frequency can be recognized and updated to the U0-16 monitor quantity.|(% style="width:96px" %)0.001
750 +)))|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Default value**|=(% style="text-align: center; vertical-align: middle; width: 110px;" %)**Range**|=(% style="text-align: center; vertical-align: middle; width: 400px;" %)**Definition**|=(% style="text-align: center; vertical-align: middle;" %)**Unit**
751 +|P4-11|Enable low-frequency vibration suppression function|(((
752 +Operation
766 766  
754 +setting
755 +)))|(((
756 +Effective
757 +
758 +immediately
759 +)))|0|0 to 1|When the function code is set to 1, enable the low-frequency vibration suppression function.|
760 +|P4-12|Low-frequency vibration suppression frequency|(((
761 +Operation
762 +
763 +setting
764 +)))|(((
765 +Effective
766 +
767 +immediately
768 +)))|800|10 to 2000|Set the vibration frequency when vibration occurs at the load end.|0.1HZ
769 +|P4-14|Shutdown vibration detection amplitude|(((
770 +Operation
771 +
772 +setting
773 +)))|(((
774 +Effective
775 +
776 +immediately
777 +)))|100|0 to 1000|When the vibration amplitude is greater than (P5-12*P4-14 detection amplitude ratio), the low-frequency vibration frequency can be recognized and updated to the U0-16 monitor quantity.|0.001
778 +
767 767  **(1) Vibration frequency detection:**
768 768  
769 769  * Users can measure vibration by measuring equipment such as laser displacement.