Changes for page 07 Adjustments
Last modified by Iris on 2025/07/24 11:03
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Content
-
... ... @@ -743,65 +743,12 @@ 743 743 [[**Figure 7-13 Applicable working conditions for low-frequency vibration suppression**>>image:20230516-0713.png||id="20230516-0713.png"]] 744 744 ))) 745 745 746 -|=(% scope="row" style="text-align: center; vertical-align: middle; width: 120px;" %)**Function code**|=(% style="text-align: center; vertical-align: middle; width: 155px;" %)**Name**|=(% style="text-align:37px;" %)(((746 +|=(% scope="row" style="text-align: center; vertical-align: middle; width: 120px;" %)**Function code**|=(% style="text-align: center; vertical-align: middle; width: 250px;" %)**Name**|=(% style="text-align:center; vertical-align:middle; width:150px" %)((( 747 747 **Setting method** 748 -)))|=(% style="text-align: 15px;" %)(((748 +)))|=(% style="text-align:center; vertical-align:middle; width:128px" %)((( 749 749 **Effective time** 750 -)))|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Default value**|=(% style="text-align: center; vertical-align: middle; width: 100px;" %)**Range**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Definition**|=(% style="text-align: center; vertical-align: middle; width: 96px;" %)**Unit** 751 -|=(% style="text-align:center; vertical-align:middle" %)P4-11|(% style="width:294px" %)Enable low-frequency vibration suppression function|(% style="text-align:center; vertical-align:middle; width:137px" %)((( 752 -Operation setting 753 -)))|(% style="text-align:center; vertical-align:middle; width:156px" %)((( 754 -Effective immediately 755 -)))|(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle; width:126px" %)0 to 1|(% style="width:448px" %)When the function code is set to 1, enable the low-frequency vibration suppression function.|(% style="width:96px" %) 756 -|=(% style="text-align:center; vertical-align:middle" %)P4-12|(% style="width:294px" %)Low-frequency vibration suppression frequency|(% style="text-align:center; vertical-align:middle; width:137px" %)((( 757 -Operation setting 758 -)))|(% style="text-align:center; vertical-align:middle; width:156px" %)((( 759 -Effective immediately 760 -)))|(% style="text-align:center; vertical-align:middle" %)800|(% style="text-align:center; vertical-align:middle; width:126px" %)10 to 2000|(% style="width:448px" %)Set the vibration frequency when vibration occurs at the load end.|(% style="text-align:center; vertical-align:middle; width:96px" %)0.1HZ 761 -|=(% style="text-align:center; vertical-align:middle" %)P4-14|(% style="width:294px" %)Shutdown vibration detection amplitude|(% style="text-align:center; vertical-align:middle; width:137px" %)((( 762 -Operation setting 763 -)))|(% style="text-align:center; vertical-align:middle; width:156px" %)((( 764 -Effective immediately 765 -)))|(% style="text-align:center; vertical-align:middle" %)100|(% style="text-align:center; vertical-align:middle; width:126px" %)0 to 1000|(% style="width:448px" %)When the vibration amplitude is greater than (P5-12*P4-14 detection amplitude ratio), the low-frequency vibration frequency can be recognized and updated to the U0-16 monitor quantity.|(% style="text-align:center; vertical-align:middle; width:96px" %)0.001 766 - 767 -**Vibration frequency detection:** 768 - 769 -* Users can measure vibration by measuring equipment such as laser displacement. 770 -* If no measuring equipment, the user can also read the position deviation waveform to confirm the vibration frequency through the "waveform" function of the PC debugging software. 771 -* Low-frequency vibration detection needs to be coordinated by the two parameters of completion positioning threshold and vibration detection amplitude. When the vibration amplitude is greater than (P5-12*P4-14 detection amplitude ratio), the low-frequency vibration frequency can be recognized and updated to U0-16 monitoring quantity. For example, when the vibration amplitude is greater than (P5-12*P4-14*0.001) detection amplitude ratio. For example, in P05-12=800, P04_14=50, the vibration amplitude is greater than P5-12*P4-14*0.001=800*50*0.001=40 pulses, stop vibration frequency can be identified in U0-16. 772 - 773 -**Debugging method:** 774 - 775 -* Set the appropriate positioning completion thresholds P5-12 and P4-14 to help the software detect the vibration frequency. 776 -* Run the position curve command to obtain the vibration frequency, and obtain the frequency through the speed curve of oscilloscope or U0-16. 777 -* Set P4-12 vibration frequency and enable low frequency vibration suppression function P4-11. 778 -* Run again to observe the speed waveform and determine whether to eliminate the vibration. If the vibration is not eliminated, please manually modify the vibration frequency and try again. 779 - 780 -(% class="table-bordered" style="margin-right:auto" %) 781 -(% class="warning" %)|(% style="text-align:center; vertical-align:middle" %)[[image:image-20230516105941-2.png]] 782 -|(% style="text-align:left; vertical-align:middle" %)Note: If there is a speed substantial vibration and the vibration increases during the debugging, it may be that the low-frequency vibration suppression is not suitable for the current working conditions, please immediately close the servo, or power down! 783 - 784 -== Type A vibration suppression == 785 - 786 -Type A vibration suppression is suitable for durational vibration during motor operation or shutdown. Use Type A suppression to help reduce vibrations at specific frequencies that occur during motion (For the situation where the vibration continues to maintain and the vibration amplitude is almost constant after the command is completed.) As shown in Figure 7-14. 787 - 788 -(% style="text-align:center" %) 789 -((( 790 -(% class="wikigeneratedid img-thumbnail" style="display:inline-block" %) 791 -[[**Figure 7-14 Applicable situations for type A vibration suppression**>>image:20230516-0714.png]] 792 -))) 793 - 794 - 795 -|**Function code**|**Name**|((( 796 -**Setting** 797 - 798 -**method** 799 -)))|((( 800 -**Effective** 801 - 802 -**time** 803 -)))|**Default**|**Range**|**Definition**|**Unit** 804 -|P4-19|Enable the type A suppression function|((( 750 +)))|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Default value**|=(% style="text-align: center; vertical-align: middle; width: 107px;" %)**Range**|=(% style="text-align: center; vertical-align: middle; width: 350px;" %)**Definition**|=(% style="text-align: center; vertical-align: middle;" %)**Unit** 751 +|P4-11|Enable low-frequency vibration suppression function|((( 805 805 Operation 806 806 807 807 setting ... ... @@ -809,8 +809,8 @@ 809 809 Effective 810 810 811 811 immediately 812 -)))|0|0 to 1|When the function code is set to 1, enable the typeAsuppression function.|813 -|P4-2 0|TypeAsuppression frequency|(((759 +)))|0|0 to 1|When the function code is set to 1, enable the low-frequency vibration suppression function.| 760 +|P4-12|Low-frequency vibration suppression frequency|((( 814 814 Operation 815 815 816 816 setting ... ... @@ -818,8 +818,8 @@ 818 818 Effective 819 819 820 820 immediately 821 -)))| 1000|100to0|Set the frequencyof TypeAsuppression.|0.1HZ822 -|P4- 21|Type A suppressiongaincorrection|(((768 +)))|800|10 to 2000|Set the vibration frequency when vibration occurs at the load end.|0.1HZ 769 +|P4-14|Shutdown vibration detection amplitude|((( 823 823 Operation 824 824 825 825 setting ... ... @@ -827,38 +827,30 @@ 827 827 Effective 828 828 829 829 immediately 830 -)))|100|0 to 1000|Correct the load inertia ratio size.|0.01 831 -|P4-22|Type A suppression damping gain|((( 832 -Operation 777 +)))|100|0 to 1000|When the vibration amplitude is greater than (P5-12*P4-14 detection amplitude ratio), the low-frequency vibration frequency can be recognized and updated to the U0-16 monitor quantity.|0.001 833 833 834 -setting 835 -)))|((( 836 -Effective 779 +**(1) Vibration frequency detection:** 837 837 838 -immediately 839 -)))|0|0 to 500|The type A rejection compensation value is gradually increased until the vibration is reduced to the acceptable range.|0.01 840 -|P4-23|Type A suppression phase correction|((( 841 -Operation 781 +* Users can measure vibration by measuring equipment such as laser displacement. 782 +* If no measuring equipment, the user can also read the position deviation waveform to confirm the vibration frequency through the "waveform" function of the PC debugging software. 783 +* Low-frequency vibration detection needs to be coordinated by the two parameters of completion positioning threshold and vibration detection amplitude. When the vibration amplitude is greater than (P5-12*P4-14 detection amplitude ratio), the low-frequency vibration frequency can be recognized and updated to U0-16 monitoring quantity. For example, when the vibration amplitude is greater than (P5-12*P4-14*0.001) detection amplitude ratio. For example, in P05-12=800, P04_14=50, the vibration amplitude is greater than P5-12*P4-14*0.001=800*50*0.001=40 pulses, stop vibration frequency can be identified in U0-16. 842 842 843 -setting 844 -)))|((( 845 -Effective 785 +**(2) Debugging method:** 846 846 847 -immediately 848 -)))|200|0 to 900|Type A suppression phase compensation.|0.1 degree 787 +* Set the appropriate positioning completion thresholds P5-12 and P4-14 to help the software detect the vibration frequency. 788 +* Run the position curve command to obtain the vibration frequency, and obtain the frequency through the speed curve of oscilloscope or U0-16. 789 +* Set P4-12 vibration frequency and enable low frequency vibration suppression function P4-11. 790 +* Run again to observe the speed waveform and determine whether to eliminate the vibration. If the vibration is not eliminated, please manually modify the vibration frequency and try again. 849 849 850 -**Vibration frequency detection:** 792 +|[[image:image-20230516105941-2.png]] 793 +|Note: If there is a speed substantial vibration and the vibration increases during the debugging, it may be that the low-frequency vibration suppression is not suitable for the current working conditions, please immediately close the servo, or power down! 851 851 852 - Thevibration frequencycan directlyobtainthevalue of the current vibrationfrequency from thesoftware oscilloscope vibration frequency, combined with real-timespeed waveform to observe the current vibrationsituation.795 +== Type A vibration suppression == 853 853 854 - **Debugging method:**797 +Type A vibration suppression is suitable for durational vibration during motor operation or shutdown. Use Type A suppression to help reduce vibrations at specific frequencies that occur during motion (For the situation where the vibration continues to maintain and the vibration amplitude is almost constant after the command is completed.) As shown in Figure 7-14. 855 855 856 -* Please set the correct inertia ratio parameter P3-1 when using type A vibration suppression, 857 -* Run the position curve command, observe the servo host computer software waveform interface (sine wave) to obtain the vibration frequency. 858 -* Set P4-20 vibration frequency and enable type A vibration suppression function P4-19. ( Type A vibration frequency takes effect when P4-19 is set to 1 for the first time. If change A-type vibration frequency P4-20, please set P4-19 to 0 again, then set to 1) 859 -* Set P4-22 damping gain, gradually increasing from 0, each time increasing about 20. 860 -* Observe the size of the vibration speed component, if the amplitude speed component is getting larger, it can be the vibration frequency setting error, if the vibration speed component is getting smaller, it means the vibration is gradually suppressed. 861 -* When the vibration is suppressed, there is still a small part of the vibration speed component, users can fine-tune the P4-23 phase correction, the recommended value of 150~~300. 862 - 863 -|[[image:image-20230516135116-1.png]] 864 -|Note: If there is a speed substantial vibration and the vibration increases during the debugging, it may be that the low-frequency vibration suppression is not suitable for the current working conditions, please immediately close the servo, or power down! 799 +(% style="text-align:center" %) 800 +((( 801 +(% class="wikigeneratedid img-thumbnail" style="display:inline-block" %) 802 +[[**Figure 7-14 Applicable situations for type A vibration suppression**>>image:20230516-0714.png||id="20230516-0714.png"]] 803 +)))
- image-20230516135116-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Karen - Size
-
... ... @@ -1,1 +1,0 @@ 1 -1.8 KB - Content