Changes for page 07 Adjustments
Last modified by Iris on 2025/07/24 11:03
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Content
-
... ... @@ -788,77 +788,5 @@ 788 788 (% style="text-align:center" %) 789 789 ((( 790 790 (% class="wikigeneratedid img-thumbnail" style="display:inline-block" %) 791 -[[**Figure 7-14 Applicable situations for type A vibration suppression**>>image:20230516-0714.png]] 791 +[[**Figure 7-14 Applicable situations for type A vibration suppression**>>image:20230516-0714.png||id="20230516-0714.png"]] 792 792 ))) 793 - 794 - 795 -|**Function code**|**Name**|((( 796 -**Setting** 797 - 798 -**method** 799 -)))|((( 800 -**Effective** 801 - 802 -**time** 803 -)))|**Default**|**Range**|**Definition**|**Unit** 804 -|P4-19|Enable the type A suppression function|((( 805 -Operation 806 - 807 -setting 808 -)))|((( 809 -Effective 810 - 811 -immediately 812 -)))|0|0 to 1|When the function code is set to 1, enable the type A suppression function.| 813 -|P4-20|Type A suppression frequency|((( 814 -Operation 815 - 816 -setting 817 -)))|((( 818 -Effective 819 - 820 -immediately 821 -)))|1000|100 to 20000|Set the frequency of Type A suppression.|0.1HZ 822 -|P4-21|Type A suppression gain correction|((( 823 -Operation 824 - 825 -setting 826 -)))|((( 827 -Effective 828 - 829 -immediately 830 -)))|100|0 to 1000|Correct the load inertia ratio size.|0.01 831 -|P4-22|Type A suppression damping gain|((( 832 -Operation 833 - 834 -setting 835 -)))|((( 836 -Effective 837 - 838 -immediately 839 -)))|0|0 to 500|The type A rejection compensation value is gradually increased until the vibration is reduced to the acceptable range.|0.01 840 -|P4-23|Type A suppression phase correction|((( 841 -Operation 842 - 843 -setting 844 -)))|((( 845 -Effective 846 - 847 -immediately 848 -)))|200|0 to 900|Type A suppression phase compensation.|0.1 degree 849 - 850 -**Vibration frequency detection:** 851 - 852 -The vibration frequency can directly obtain the value of the current vibration frequency from the software oscilloscope vibration frequency, combined with real-time speed waveform to observe the current vibration situation. 853 - 854 -**Debugging method:** 855 - 856 -* Please set the correct inertia ratio parameter P3-1 when using type A vibration suppression, 857 -* Run the position curve command, observe the servo host computer software waveform interface (sine wave) to obtain the vibration frequency. 858 -* Set P4-20 vibration frequency and enable type A vibration suppression function P4-19. ( Type A vibration frequency takes effect when P4-19 is set to 1 for the first time. If change A-type vibration frequency P4-20, please set P4-19 to 0 again, then set to 1) 859 -* Set P4-22 damping gain, gradually increasing from 0, each time increasing about 20. 860 -* Observe the size of the vibration speed component, if the amplitude speed component is getting larger, it can be the vibration frequency setting error, if the vibration speed component is getting smaller, it means the vibration is gradually suppressed. 861 -* When the vibration is suppressed, there is still a small part of the vibration speed component, users can fine-tune the P4-23 phase correction, the recommended value of 150~~300. 862 - 863 -|[[image:image-20230516135116-1.png]] 864 -|Note: If there is a speed substantial vibration and the vibration increases during the debugging, it may be that the low-frequency vibration suppression is not suitable for the current working conditions, please immediately close the servo, or power down!
- image-20230516135116-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Karen - Size
-
... ... @@ -1,1 +1,0 @@ 1 -1.8 KB - Content