Changes for page 07 Adjustments

Last modified by Iris on 2025/07/24 11:03

From version 58.2
edited by Karen
on 2023/05/16 13:52
Change comment: There is no comment for this version
To version 58.6
edited by Karen
on 2023/05/16 13:58
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -791,60 +791,35 @@
791 791  [[**Figure 7-14 Applicable situations for type A vibration suppression**>>image:20230516-0714.png]]
792 792  )))
793 793  
794 -
795 -|**Function code**|**Name**|(((
796 -**Setting**
797 -
798 -**method**
799 -)))|(((
800 -**Effective**
801 -
802 -**time**
803 -)))|**Default**|**Range**|**Definition**|**Unit**
794 +|=(% scope="row" style="text-align: center; vertical-align: middle; width: 120px;" %)**Function code**|=(% style="text-align: center; vertical-align: middle; width: 155px;" %)**Name**|=(% style="text-align: center; vertical-align: middle; width: 115px;" %)(((
795 +**Setting method**
796 +)))|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)(((
797 +**Effective time**
798 +)))|=(% style="text-align: center; vertical-align: middle; width: 100px;" %)**Default value**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Range**|=(% style="text-align: center; vertical-align: middle; width: 350px;" %)**Definition**|=(% style="text-align: center; vertical-align: middle;" %)**Unit**
804 804  |P4-19|Enable the type A suppression function|(((
805 -Operation
806 -
807 -setting
800 +Operation setting
808 808  )))|(((
809 -Effective
810 -
811 -immediately
802 +Effective immediately
812 812  )))|0|0 to 1|When the function code is set to 1, enable the type A suppression function.|
813 813  |P4-20|Type A suppression frequency|(((
814 -Operation
815 -
816 -setting
805 +Operation setting
817 817  )))|(((
818 -Effective
819 -
820 -immediately
807 +Effective immediately
821 821  )))|1000|100 to 20000|Set the frequency of Type A suppression.|0.1HZ
822 822  |P4-21|Type A suppression gain correction|(((
823 -Operation
824 -
825 -setting
810 +Operation setting
826 826  )))|(((
827 -Effective
828 -
829 -immediately
812 +Effective immediately
830 830  )))|100|0 to 1000|Correct the load inertia ratio size.|0.01
831 831  |P4-22|Type A suppression damping gain|(((
832 -Operation
833 -
834 -setting
815 +Operation setting
835 835  )))|(((
836 -Effective
837 -
838 -immediately
817 +Effective immediately
839 839  )))|0|0 to 500|The type A rejection compensation value is gradually increased until the vibration is reduced to the acceptable range.|0.01
840 840  |P4-23|Type A suppression phase correction|(((
841 -Operation
842 -
843 -setting
820 +Operation setting
844 844  )))|(((
845 -Effective
846 -
847 -immediately
822 +Effective immediately
848 848  )))|200|0 to 900|Type A suppression phase compensation.|0.1 degree
849 849  
850 850  **Vibration frequency detection:**