Changes for page 07 Adjustments
Last modified by Iris on 2025/07/24 11:03
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -791,62 +791,37 @@ 791 791 [[**Figure 7-14 Applicable situations for type A vibration suppression**>>image:20230516-0714.png]] 792 792 ))) 793 793 794 +|=(% scope="row" style="text-align: center; vertical-align: middle; width: 120px;" %)**Function code**|=(% style="text-align: center; vertical-align: middle; width: 155px;" %)**Name**|=(% style="text-align: center; vertical-align: middle; width: 115px;" %)((( 795 +**Setting method** 796 +)))|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)((( 797 +**Effective time** 798 +)))|=(% style="text-align: center; vertical-align: middle; width: 100px;" %)**Default value**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Range**|=(% style="text-align: center; vertical-align: middle; width: 618px;" %)**Definition**|=(% style="text-align: center; vertical-align: middle; width: 142px;" %)**Unit** 799 +|=(% style="text-align: center; vertical-align: middle" %)P4-19|Enable the type A suppression function|(% style="text-align:center; vertical-align:middle" %)((( 800 +Operation setting 801 +)))|(% style="text-align:center; vertical-align:middle" %)((( 802 +Effective immediately 803 +)))|(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)0 to 1|(% style="width:618px" %)When the function code is set to 1, enable the type A suppression function.| 804 +|=(% style="text-align: center; vertical-align: middle" %)P4-20|Type A suppression frequency|(% style="text-align:center; vertical-align:middle" %)((( 805 +Operation setting 806 +)))|(% style="text-align:center; vertical-align:middle" %)((( 807 +Effective immediately 808 +)))|(% style="text-align:center; vertical-align:middle" %)1000|(% style="text-align:center; vertical-align:middle" %)100 to 20000|(% style="width:618px" %)Set the frequency of Type A suppression.|(% style="text-align: center; vertical-align: middle ; width:142px" %)0.1HZ 809 +|=(% style="text-align: center; vertical-align: middle" %)P4-21|Type A suppression gain correction|(% style="text-align:center; vertical-align:middle" %)((( 810 +Operation setting 811 +)))|(% style="text-align:center; vertical-align:middle" %)((( 812 +Effective immediately 813 +)))|(% style="text-align:center; vertical-align:middle" %)100|(% style="text-align:center; vertical-align:middle" %)0 to 1000|(% style="width:618px" %)Correct the load inertia ratio size.|(% style="text-align:center; vertical-align:middle; width:142px" %)0.01 814 +|=(% style="text-align: center; vertical-align: middle" %)P4-22|Type A suppression damping gain|(% style="text-align:center; vertical-align:middle" %)((( 815 +Operation setting 816 +)))|(% style="text-align:center; vertical-align:middle" %)((( 817 +Effective immediately 818 +)))|(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)0 to 500|(% style="width:618px" %)The type A rejection compensation value is gradually increased until the vibration is reduced to the acceptable range.|(% style="text-align:center; vertical-align:middle; width:142px" %)0.01 819 +|=(% style="text-align: center; vertical-align: middle" %)P4-23|Type A suppression phase correction|(% style="text-align:center; vertical-align:middle" %)((( 820 +Operation setting 821 +)))|(% style="text-align:center; vertical-align:middle" %)((( 822 +Effective immediately 823 +)))|(% style="text-align:center; vertical-align:middle" %)200|(% style="text-align:center; vertical-align:middle" %)0 to 900|(% style="width:618px" %)Type A suppression phase compensation.|(% style="text-align:center; vertical-align:middle; width:142px" %)0.1 degree 794 794 795 -|**Function code**|**Name**|((( 796 -**Setting** 797 - 798 -**method** 799 -)))|((( 800 -**Effective** 801 - 802 -**time** 803 -)))|**Default**|**Range**|**Definition**|**Unit** 804 -|P4-19|Enable the type A suppression function|((( 805 -Operation 806 - 807 -setting 808 -)))|((( 809 -Effective 810 - 811 -immediately 812 -)))|0|0 to 1|When the function code is set to 1, enable the type A suppression function.| 813 -|P4-20|Type A suppression frequency|((( 814 -Operation 815 - 816 -setting 817 -)))|((( 818 -Effective 819 - 820 -immediately 821 -)))|1000|100 to 20000|Set the frequency of Type A suppression.|0.1HZ 822 -|P4-21|Type A suppression gain correction|((( 823 -Operation 824 - 825 -setting 826 -)))|((( 827 -Effective 828 - 829 -immediately 830 -)))|100|0 to 1000|Correct the load inertia ratio size.|0.01 831 -|P4-22|Type A suppression damping gain|((( 832 -Operation 833 - 834 -setting 835 -)))|((( 836 -Effective 837 - 838 -immediately 839 -)))|0|0 to 500|The type A rejection compensation value is gradually increased until the vibration is reduced to the acceptable range.|0.01 840 -|P4-23|Type A suppression phase correction|((( 841 -Operation 842 - 843 -setting 844 -)))|((( 845 -Effective 846 - 847 -immediately 848 -)))|200|0 to 900|Type A suppression phase compensation.|0.1 degree 849 - 850 850 **Vibration frequency detection:** 851 851 852 852 The vibration frequency can directly obtain the value of the current vibration frequency from the software oscilloscope vibration frequency, combined with real-time speed waveform to observe the current vibration situation.