... ... @@ -791,62 +791,37 @@
791 791  [[**Figure 7-14 Applicable situations for type A vibration suppression**>>image:20230516-0714.png]]
792 792  )))
793 793  
794 +|=(% scope="row" style="text-align: center; vertical-align: middle; width: 120px;" %)**Function code**|=(% style="text-align: center; vertical-align: middle; width: 155px;" %)**Name**|=(% style="text-align: center; vertical-align: middle; width: 115px;" %)(((
795 +**Setting method**
796 +)))|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)(((
797 +**Effective time**
798 +)))|=(% style="text-align: center; vertical-align: middle; width: 100px;" %)**Default value**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Range**|=(% style="text-align: center; vertical-align: middle; width: 618px;" %)**Definition**|=(% style="text-align: center; vertical-align: middle; width: 142px;" %)**Unit**
799 +|=(% style="text-align: center; vertical-align: middle" %)P4-19|Enable the type A suppression function|(% style="text-align:center; vertical-align:middle" %)(((
800 +Operation setting
801 +)))|(% style="text-align:center; vertical-align:middle" %)(((
802 +Effective immediately
803 +)))|(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)0 to 1|(% style="width:618px" %)When the function code is set to 1, enable the type A suppression function.|
804 +|=(% style="text-align: center; vertical-align: middle" %)P4-20|Type A suppression frequency|(% style="text-align:center; vertical-align:middle" %)(((
805 +Operation setting
806 +)))|(% style="text-align:center; vertical-align:middle" %)(((
807 +Effective immediately
808 +)))|(% style="text-align:center; vertical-align:middle" %)1000|(% style="text-align:center; vertical-align:middle" %)100 to 20000|(% style="width:618px" %)Set the frequency of Type A suppression.|(% style="text-align:center; vertical-align:middle; width:142px" %)0.1HZ
809 +|=(% style="text-align: center; vertical-align: middle" %)P4-21|Type A suppression gain correction|(% style="text-align:center; vertical-align:middle" %)(((
810 +Operation setting
811 +)))|(% style="text-align:center; vertical-align:middle" %)(((
812 +Effective immediately
813 +)))|(% style="text-align:center; vertical-align:middle" %)100|(% style="text-align:center; vertical-align:middle" %)0 to 1000|(% style="width:618px" %)Correct the load inertia ratio size.|(% style="text-align:center; vertical-align:middle; width:142px" %)0.01
814 +|=(% style="text-align: center; vertical-align: middle" %)P4-22|Type A suppression damping gain|(% style="text-align:center; vertical-align:middle" %)(((
815 +Operation setting
816 +)))|(% style="text-align:center; vertical-align:middle" %)(((
817 +Effective immediately
818 +)))|(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)0 to 500|(% style="width:618px" %)The type A rejection compensation value is gradually increased until the vibration is reduced to the acceptable range.|(% style="text-align:center; vertical-align:middle; width:142px" %)0.01
819 +|=(% style="text-align: center; vertical-align: middle" %)P4-23|Type A suppression phase correction|(% style="text-align:center; vertical-align:middle" %)(((
820 +Operation setting
821 +)))|(% style="text-align:center; vertical-align:middle" %)(((
822 +Effective immediately
823 +)))|(% style="text-align:center; vertical-align:middle" %)200|(% style="text-align:center; vertical-align:middle" %)0 to 900|(% style="width:618px" %)Type A suppression phase compensation.|(% style="text-align:center; vertical-align:middle; width:142px" %)0.1 degree
794 794  
795 -|**Function code**|**Name**|(((
796 -**Setting**
797 -
798 -**method**
799 -)))|(((
800 -**Effective**
801 -
802 -**time**
803 -)))|**Default**|**Range**|**Definition**|**Unit**
804 -|P4-19|Enable the type A suppression function|(((
805 -Operation
806 -
807 -setting
808 -)))|(((
809 -Effective
810 -
811 -immediately
812 -)))|0|0 to 1|When the function code is set to 1, enable the type A suppression function.|
813 -|P4-20|Type A suppression frequency|(((
814 -Operation
815 -
816 -setting
817 -)))|(((
818 -Effective
819 -
820 -immediately
821 -)))|1000|100 to 20000|Set the frequency of Type A suppression.|0.1HZ
822 -|P4-21|Type A suppression gain correction|(((
823 -Operation
824 -
825 -setting
826 -)))|(((
827 -Effective
828 -
829 -immediately
830 -)))|100|0 to 1000|Correct the load inertia ratio size.|0.01
831 -|P4-22|Type A suppression damping gain|(((
832 -Operation
833 -
834 -setting
835 -)))|(((
836 -Effective
837 -
838 -immediately
839 -)))|0|0 to 500|The type A rejection compensation value is gradually increased until the vibration is reduced to the acceptable range.|0.01
840 -|P4-23|Type A suppression phase correction|(((
841 -Operation
842 -
843 -setting
844 -)))|(((
845 -Effective
846 -
847 -immediately
848 -)))|200|0 to 900|Type A suppression phase compensation.|0.1 degree
849 -
850 850  **Vibration frequency detection:**
851 851  
852 852  The vibration frequency can directly obtain the value of the current vibration frequency from the software oscilloscope vibration frequency, combined with real-time speed waveform to observe the current vibration situation.
... ... @@ -860,5 +860,6 @@
860 860  * Observe the size of the vibration speed component, if the amplitude speed component is getting larger, it can be the vibration frequency setting error, if the vibration speed component is getting smaller, it means the vibration is gradually suppressed.
861 861  * When the vibration is suppressed, there is still a small part of the vibration speed component, users can fine-tune the P4-23 phase correction, the recommended value of 150~~300.
862 862  
863 -|[[image:image-20230516135116-1.png]]
864 -|Note: If there is a speed substantial vibration and the vibration increases during the debugging, it may be that the low-frequency vibration suppression is not suitable for the current working conditions, please immediately close the servo, or power down!
838 +(% class="table-bordered" style="margin-right:auto" %)
839 +(% class="warning" %)|(% style="text-align:center; vertical-align:middle" %)[[image:image-20230516135116-1.png]]
840 +|(% style="text-align:left; vertical-align:middle" %)Note: If there is a speed substantial vibration and the vibration increases during the debugging, it may be that the low-frequency vibration suppression is not suitable for the current working conditions, please immediately close the servo, or power down!