Changes for page 07 Adjustments
Last modified by Iris on 2025/07/24 11:03
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -791,37 +791,62 @@ 791 791 [[**Figure 7-14 Applicable situations for type A vibration suppression**>>image:20230516-0714.png]] 792 792 ))) 793 793 794 -|=(% scope="row" style="text-align: center; vertical-align: middle; width: 120px;" %)**Function code**|=(% style="text-align: center; vertical-align: middle; width: 155px;" %)**Name**|=(% style="text-align: center; vertical-align: middle; width: 115px;" %)((( 795 -**Setting method** 796 -)))|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)((( 797 -**Effective time** 798 -)))|=(% style="text-align: center; vertical-align: middle; width: 100px;" %)**Default value**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Range**|=(% style="text-align: center; vertical-align: middle; width: 618px;" %)**Definition**|=(% style="text-align: center; vertical-align: middle; width: 142px;" %)**Unit** 799 -|=(% style="text-align: center; vertical-align: middle " %)P4-19|Enable the type A suppression function|(% style="text-align: center; vertical-align: middle " %)((( 800 -Operation setting 801 -)))|(% style="text-align: center; vertical-align: middle " %)((( 802 -Effective immediately 803 -)))|(% style="text-align: center; vertical-align: middle " %)0|(% style="text-align: center; vertical-align: middle " %)0 to 1|(% style="width:618px" %)When the function code is set to 1, enable the type A suppression function.|\\ 804 -|=(% style="text-align: center; vertical-align: middle " %)P4-20|Type A suppression frequency|(% style="text-align: center; vertical-align: middle " %)((( 805 -Operation setting 806 -)))|(% style="text-align: center; vertical-align: middle " %)((( 807 -Effective immediately 808 -)))|(% style="text-align: center; vertical-align: middle " %)1000|(% style="text-align: center; vertical-align: middle " %)100 to 20000|(% style="width:618px" %)Set the frequency of Type A suppression.|(% style="width:142px" %)0.1HZ 809 -|=(% style="text-align: center; vertical-align: middle " %)P4-21|Type A suppression gain correction|(% style="text-align: center; vertical-align: middle " %)((( 810 -Operation setting 811 -)))|(% style="text-align: center; vertical-align: middle " %)((( 812 -Effective immediately 813 -)))|(% style="text-align: center; vertical-align: middle " %)100|(% style="text-align: center; vertical-align: middle " %)0 to 1000|(% style="width:618px" %)Correct the load inertia ratio size.|(% style="text-align: center; vertical-align: middle; width:142px" %)0.01 814 -|=(% style="text-align: center; vertical-align: middle " %)P4-22|Type A suppression damping gain|(% style="text-align: center; vertical-align: middle " %)((( 815 -Operation setting 816 -)))|(% style="text-align: center; vertical-align: middle " %)((( 817 -Effective immediately 818 -)))|(% style="text-align: center; vertical-align: middle " %)0|(% style="text-align: center; vertical-align: middle " %)0 to 500|(% style="width:618px" %)The type A rejection compensation value is gradually increased until the vibration is reduced to the acceptable range.|(% style="text-align: center; vertical-align: middle; width:142px" %)0.01 819 -|=(% style="text-align: center; vertical-align: middle " %)P4-23|Type A suppression phase correction|(% style="text-align: center; vertical-align: middle " %)((( 820 -Operation setting 821 -)))|(% style="text-align: center; vertical-align: middle " %)((( 822 -Effective immediately 823 -)))|(% style="text-align: center; vertical-align: middle " %)200|(% style="text-align: center; vertical-align: middle " %)0 to 900|(% style="width:618px" %)Type A suppression phase compensation.|(% style="text-align: center; vertical-align: middle; width:142px" %)0.1 degree 824 824 795 +|**Function code**|**Name**|((( 796 +**Setting** 797 + 798 +**method** 799 +)))|((( 800 +**Effective** 801 + 802 +**time** 803 +)))|**Default**|**Range**|**Definition**|**Unit** 804 +|P4-19|Enable the type A suppression function|((( 805 +Operation 806 + 807 +setting 808 +)))|((( 809 +Effective 810 + 811 +immediately 812 +)))|0|0 to 1|When the function code is set to 1, enable the type A suppression function.| 813 +|P4-20|Type A suppression frequency|((( 814 +Operation 815 + 816 +setting 817 +)))|((( 818 +Effective 819 + 820 +immediately 821 +)))|1000|100 to 20000|Set the frequency of Type A suppression.|0.1HZ 822 +|P4-21|Type A suppression gain correction|((( 823 +Operation 824 + 825 +setting 826 +)))|((( 827 +Effective 828 + 829 +immediately 830 +)))|100|0 to 1000|Correct the load inertia ratio size.|0.01 831 +|P4-22|Type A suppression damping gain|((( 832 +Operation 833 + 834 +setting 835 +)))|((( 836 +Effective 837 + 838 +immediately 839 +)))|0|0 to 500|The type A rejection compensation value is gradually increased until the vibration is reduced to the acceptable range.|0.01 840 +|P4-23|Type A suppression phase correction|((( 841 +Operation 842 + 843 +setting 844 +)))|((( 845 +Effective 846 + 847 +immediately 848 +)))|200|0 to 900|Type A suppression phase compensation.|0.1 degree 849 + 825 825 **Vibration frequency detection:** 826 826 827 827 The vibration frequency can directly obtain the value of the current vibration frequency from the software oscilloscope vibration frequency, combined with real-time speed waveform to observe the current vibration situation.