Changes for page 07 Adjustments
Last modified by Iris on 2025/07/24 11:03
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -795,27 +795,27 @@ 795 795 )))|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)((( 796 796 **Effective time** 797 797 )))|=(% style="text-align: center; vertical-align: middle; width: 100px;" %)**Default value**|=(% style="text-align: center; vertical-align: middle; width: 120px;" %)**Range**|=(% style="text-align: center; vertical-align: middle; width: 618px;" %)**Definition**|=(% style="text-align: center; vertical-align: middle; width: 96px" %)**Unit** 798 -|=(% style="text-align: center; vertical-align: middle" %)P4-19|(% style="text-align: 798 +|=(% style="text-align: center; vertical-align: middle" %)P4-19|(% style="text-align:center; vertical-align:middle" %)Enable the type A suppression function|(% style="text-align:center; vertical-align:middle" %)((( 799 799 Operation setting 800 800 )))|(% style="text-align:center; vertical-align:middle" %)((( 801 801 Effective immediately 802 802 )))|(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)0 to 1|(% style="width:618px" %)When the function code is set to 1, enable the type A suppression function.| 803 -|=(% style="text-align: center; vertical-align: middle" %)P4-20|(% style="text-align: 803 +|=(% style="text-align: center; vertical-align: middle" %)P4-20|(% style="text-align:center; vertical-align:middle" %)Type A suppression frequency|(% style="text-align:center; vertical-align:middle" %)((( 804 804 Operation setting 805 805 )))|(% style="text-align:center; vertical-align:middle" %)((( 806 806 Effective immediately 807 807 )))|(% style="text-align:center; vertical-align:middle" %)1000|(% style="text-align:center; vertical-align:middle" %)100 to 20000|(% style="width:618px" %)Set the frequency of Type A suppression.|(% style="text-align:center; vertical-align:middle" %)0.1HZ 808 -|=(% style="text-align: center; vertical-align: middle" %)P4-21|(% style="text-align: 808 +|=(% style="text-align: center; vertical-align: middle" %)P4-21|(% style="text-align:center; vertical-align:middle" %)Type A suppression gain correction|(% style="text-align:center; vertical-align:middle" %)((( 809 809 Operation setting 810 810 )))|(% style="text-align:center; vertical-align:middle" %)((( 811 811 Effective immediately 812 812 )))|(% style="text-align:center; vertical-align:middle" %)100|(% style="text-align:center; vertical-align:middle" %)0 to 1000|(% style="width:618px" %)Correct the load inertia ratio size.|(% style="text-align:center; vertical-align:middle" %)0.01 813 -|=(% style="text-align: center; vertical-align: middle" %)P4-22|(% style="text-align: 813 +|=(% style="text-align: center; vertical-align: middle" %)P4-22|(% style="text-align:center; vertical-align:middle" %)Type A suppression damping gain|(% style="text-align:center; vertical-align:middle" %)((( 814 814 Operation setting 815 815 )))|(% style="text-align:center; vertical-align:middle" %)((( 816 816 Effective immediately 817 817 )))|(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)0 to 500|(% style="width:618px" %)The type A rejection compensation value is gradually increased until the vibration is reduced to the acceptable range.|(% style="text-align:center; vertical-align:middle" %)0.01 818 -|=(% style="text-align: center; vertical-align: middle" %)P4-23|(% style="text-align: 818 +|=(% style="text-align: center; vertical-align: middle" %)P4-23|(% style="text-align:center; vertical-align:middle" %)Type A suppression phase correction|(% style="text-align:center; vertical-align:middle" %)((( 819 819 Operation setting 820 820 )))|(% style="text-align:center; vertical-align:middle" %)((( 821 821 Effective immediately