Changes for page 07 Adjustments
Last modified by Iris on 2025/07/24 11:03
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -745,6 +745,8 @@ 745 745 746 746 Low-frequency vibration suppression is suitable for working conditions where the motor vibrates during deceleration and shutdown after the position command is sent, and the vibration amplitude gradually decreases. The use of the low-frequency vibration suppression function is effective in reducing the time to complete positioning due to vibration effects. 747 747 748 +**VD2L drive does not support low frequency vibrartion suppression.** 749 + 748 748 (% style="text-align:center" %) 749 749 ((( 750 750 (% class="wikigeneratedid img-thumbnail" style="display:inline-block" %) ... ... @@ -793,6 +793,8 @@ 793 793 794 794 Type A vibration suppression is suitable for durational vibration during motor operation or shutdown. Use Type A suppression to help reduce vibrations at specific frequencies that occur during motion (For the situation where the vibration continues to maintain and the vibration amplitude is almost constant after the command is completed.) As shown in Figure 7-14. 795 795 798 +**VD2L drive does not support type A vibration suppression.** 799 + 796 796 (% style="text-align:center" %) 797 797 ((( 798 798 (% class="wikigeneratedid img-thumbnail" style="display:inline-block" %)