... ... @@ -168,9 +168,11 @@
168 168  )))|(% style="text-align:center; vertical-align:middle; width:105px" %)(((
169 169  Effective immediately
170 170  )))|(% style="text-align:center; vertical-align:middle; width:87px" %)0|(% style="text-align:center; vertical-align:middle; width:83px" %)0 to 2|(% style="width:431px" %)(((
171 -* 0: Rigidity grade self-adjusting mode. Position loop gain, speed loop gain, speed loop integral time constant, torque filter parameter settings are automatically adjusted according to the rigidity grade setting.
172 -* 1: Manual setting; you need to manually set the position loop gain, speed loop gain, speed loop integral time constant, torque filter parameter setting
173 -* 2: Online automatic parameter self-adjusting mode (Not implemented yet)
171 +0: Rigidity grade self-adjusting mode. Position loop gain, speed loop gain, speed loop integral time constant, torque filter parameter settings are automatically adjusted according to the rigidity grade setting.
172 +
173 +1: Manual setting; you need to manually set the position loop gain, speed loop gain, speed loop integral time constant, torque filter parameter setting
174 +
175 +2: Online automatic parameter self-adjusting mode (Not implemented yet)
174 174  )))|(% style="text-align:center; vertical-align:middle" %)-
175 175  
176 176  Table 7-4 Details of self-adjusting mode selection parameters
... ... @@ -745,6 +745,8 @@
745 745  
746 746  Low-frequency vibration suppression is suitable for working conditions where the motor vibrates during deceleration and shutdown after the position command is sent, and the vibration amplitude gradually decreases. The use of the low-frequency vibration suppression function is effective in reducing the time to complete positioning due to vibration effects.
747 747  
750 +**VD2L drive does not support low frequency vibrartion suppression.**
751 +
748 748  (% style="text-align:center" %)
749 749  (((
750 750  (% class="wikigeneratedid img-thumbnail" style="display:inline-block" %)
... ... @@ -793,6 +793,8 @@
793 793  
794 794  Type A vibration suppression is suitable for durational vibration during motor operation or shutdown. Use Type A suppression to help reduce vibrations at specific frequencies that occur during motion (For the situation where the vibration continues to maintain and the vibration amplitude is almost constant after the command is completed.) As shown in Figure 7-14.
795 795  
800 +**VD2L drive does not support type A vibration suppression.**
801 +